HomeMy WebLinkAbout32596 / 83-13October 6, 1983 #13 RESOLUTION
(CARRIED LOST LAID OVER WITHDRAWN )
PURPOSE: WAIVE BIDS AND PURCHASE ELECTROMAGNETIC FLOWMETERS
INITIATED BY: DEPARTMENT OF PUBLIC WORKS
BE IT RESOLVED by the Common Council of the City of Oshkosh that the
proper City officials are hereby authorized and directed to waive bids and
purchase four (4) electromagnetic flowmeters for the sewage treatment plant from
Jensen Reynolds, 4919 Good Hope Road, Milwaukee, WI 53233, at a cost not to exceed
$16,980.00.
BE IT FURTHER RESOLVED that money for this purpose is hereby appropriated
from Account No. 919-255, Sewer Utility,SOlids Disposal Plant Equipment.
;i')3'?;_�,�,..'.. E'✓
APPROVED
- 16 -
xESOiznzoN �k 13
To: Wil2iam Frueh, City Manager
From: Gerald Konrad, Director of Public Works
Date: September 9, 1983 „ /�//
Subject: ELECTROMAGNETIC FLOWMETERS �� ��
The sewage treatment plant has eight 3�� electromagnetic
flowmeters which operate in the air flotation thickeners.
In 1981 the four meters operating on the sludge side of the
thickeners failed, and were replaced. Now the four meters
ott the charged water side are failing. One is completely
inoperable beyond repair, and the other three have been
temporarily repaired with an expected life of only six
months.
We would like to standardize all eight meters and,
therefore, requested a quote from Jensen Reynolds, 1ow bidder
in 1981. To replace one meter at this time would cost $4475;
if a11 four were replaced the price per meter would be $4245
each, or a total of $16,980. This would be a savings of $920
over replacing the meters one at a time.
In 1981 the 1ow bid for a 3" meter was $3712.75 each, and
the second bid was $4790 each, As you can see, the present
quote is sti11 below the 1981 second bid, and approximately
14% higher than 1981 low bid. With the years 1981 and 1982 having
a fairly high inflation rate, I feel the 14% increase is
justifiable.
I would recommend that we suspend bidding procedures and
purchase the four meters as quoted in the attached quote.
Because the one meter is now inoperable, we will have to
do something fairly soon.
c.c.: Tom Konrad,
Supt. of Utilities
Enc.
- 16a -
JENSEN REYNOLDS
4919 W. GOOD HOPE ROAD
OMILWAUKEE, WISCONSIN 53223
IAL INSTRUMENTATION, METERS AND CONTROL SYSTEMS
QuorarioN
QUOTED
T0:
Ati:
REF:
ITEM QT
1 1
�
City of Oshkoah
P. o. Sox 1130
Oshkosh, �I 54902
Tom Konra3
Phone Aug. 31, 1983
Brooks-Mag 7000 Flowmeters
Phone: (414) 351-1100
Telez: 2{g426
Date: Sept. 6� 19a3
F.0.8.: � Statesboro, GA
Terms: 11et 30 days
Delivery: 4-6 wPeks
gy li�; nat-,-✓
a3'
PAGE Z OF 1
DESCRIPTION PRICE
3" - 150 lb. Flanged Model 7603A11 Brooks-'•1ag 7000 $4475.00
Electromagnetic Flowmeter with teflon liner for a Net
flow range of 0-400 GPA7 primary effluent water.
Including:
- HW-273E-117-AAA Electronics Box w/integral analog
output, 4-20 ma 3c.
- HA-441Z-136-�MT Electrade Housing, 316 SS.
- HS-270E-015-3MA Ultrasonic Bulletnose Electrode
Assembly, 316 SS.
- P/N 779�LClA1M Ultraso�ic Generator Por wall mounting
w/2� Pt. of cable P/x xs-gb9Z-576-AAA.
- 3" P/N xs-724E-354-�+ type 316 �S Groun3ing Ring.
- 3" P/N HS-577Z-185-BM,A 316 SS Protective orifice.
Alternate•
Brooks-N,ag 7000 Electroaegnetic Flovrmeters same ae above �4245.00
Net Each
The above prices include start-up assistance as
require@.
Thank you for your continued interest in our pro3ucts
and service.
Enclosure: (S) DS-7000