Loading...
HomeMy WebLinkAboutItem 8 - 530 N. Main Street Cell Equipment OSHICOSH LANDMARZ, COMMISSION TO: Landmarks Commission FROM: Steven Wiley, Staff Liaison DATE: July 1st, 2019 SUBJECT: Item 8: 530 N Main Cell Equipment-Update/Action 1.) Initiated by: Matthew Holtkamp, Architectural Historian II, EBI Consulting This property is a contributing structure in the North Main Historic District and AT&T is looking to modernize their cell equipment and antennae on the building. Landmarks initially weighed in on this back at their April meeting and determined that there would be an adverse effect to the building at 530 N Main and the North Main Historic District. Following the submission of the original letter, the consultant (EBI)reached out to staff and stated that the proposed modernizations and replacements would only occur inside the penthouse of the building and not out in public view. The email below was sent on Monday,June 241h,2019 at 1:10 pm. EBI is asking that Landmarks review the clarified scope of work and consider amending the initial determination. Hello Steven, I wanted to quickly follow up on our phone conversation last week regarding the proposed AT&T equipment modification at 530 N Main St. As I mentioned, all work will be completed within the equipment room or behind the penthouse wall and will not be visible from surrounding areas, nor will the proposed work physically impact the National-Register listed Raulf Hotel. With this clarification of the scope of work, you indicated a willingness to formally reverse the local government's objection to the project at the upcoming Historic Resources Commission meeting. Should the HRC agree to issue an opinion of No Adverse Effect, please notify me via email. I've attached the original letter EBI mailed on April 5, 2019. Please let me know if you need anything else and thanks again for understanding! Have a nice day, Matthew Holtkamp Architectural Historian II EBI Consulting If you are unable to attend this meeting,it is important to notify Steven Wiley (920-236-5062) in case a quorum cannot be attained. OSHICOSH LANDMARK-S COMMISSION 2.) Is the item related to an Historic District/contributing, listed individually, Landmarked or eligible? This property is part of the North Main Historic District and is contributing to the district. 2a.) Does item conform with all Local, State, or other Ordinances, Statutes? The project would comply with the Federal Communication Commission (FCC's) regulations. 2b.) Has the State Historical Society been notified or involved? Yes—the State has been involved and comments from the state will be included. 2c.) Are other organizations or entities involved? Yes—The Housing Authority owns the building and is also involved. 3.) Are Historic Tax Credits applicable for this item? No. 4.) Does this pertain to municipally-owned structures? No. The property is owned by the Housing Authority. 5.) What is the Commission priority#for this item? Ongoing projects and property owners that approach the Commission for input are a top priority of the Commission, along with other ongoing tasks. 5a.) Does the Commission have enough information for action(s)? The Commission should have enough information and should decide what action to take on this item. Discussion Considerations 1.) More research or follow up on Item? Not at this time unless the Commission has more specific questions. 2.) Evidence of"original"? Restore to what time period? Yes—but whether to restore back would involve removing the cell equipment from the exterior of the building. 3.) Replacement Materials: accepted by State Historical society? N/A 4.) Consideration of'undo hardship on ownersT Funding sources? Owners currently rent out the space for the cell equipment to cell companies. 5.) Take actions? The Commission should vote and take action. If you are unable to attend this meeting,it is important to notify Steven Wiley (920-236-5062) in case a quorum cannot be attained. OSHICOSH LANDMARZ, 6.) Follow up? COMMISSION Staff would assist in drafting a formal Commission response to this request. If you are unable to attend this meeting,it is important to notify Steven Wiley (920-236-5062) in case a quorum cannot be attained. City of Oshkosh Dept.of Community Development r.;It Planning Services Division 215 Church Ave.,PO Box 1130 Oshkosh,WI 54903-1130 shkosh (920)236-5059 (920)236-5053 FAX Darryn Burich,Director hftp://www.ci.oshkosh.wi.us Planning Services Division April 25, 2019 Sarah LeVaun Graulty EBI Consulting 6876 Susquehanna Trail South York, PA 17403 RE: AT&T/ 12975974/W16037 530 N Main St, Oshkosh, WI 54901 EBI Project# 6119000913 Dear Ms. Graulty, The Oshkosh Landmarks Commission is registering a statement regarding the placement of cell phone towers and antennae near a historic district. Our mission is to safeguard the historic integrity of the built structures and districts of Oshkosh and we respectfully submit our explanation: 1. Completely object to installation of a cell phone antenna on historic structures that are on the state and national historic register, eligible for the register, locally landmarked, or contributing structures within a historic district; 2. Strongly discourage installation of antenna on historic structures that are on the register or eligible for the register, locally landmarked, or contributing structures within a historic district even if they are incorporated into the building's architecture as not to be visible (because they pose a threat to the historic integrity of the building/structure); 3. Discourage installation on non-contributing structures within an historic district; but, if sited on said structures,the installation should be incorporated into the architecture and/or sited, and screened as not to be obvious or visible within the historic district; 4. Are concerned with an installation of a tower or antenna on non-contributing structures outside a historic district if they have a visual impact on a historic district or other structures of local historic significance. The AT&T project to replace antennae and install additional antennae structures on 530 N. Main Street is in an historic district. Moreover, it is on an historic structure, the city's 1927 ten-story skyscraper, the tallest building in Oshkosh's historic downtown. The proposed antennae collocation is totally inappropriate and would fit under# 1, above. The present proliferation of antennae line the perimeter of the building on 530 N. Main Street and totally distract from the historic high-rise's glazed terra cotta fagade,with pinnacles, spires, crenellated parapet, shields, and tiles. "The scale and vertical emphasis of the structure dominate this portion of Main Street and makes it a visual landmark"in the historic view-shed from the north, south, east, and west within the North Main St. Historic District and from many of the contributing historic buildings. The citizens of Oshkosh celebrated the reopening of Oshkosh's Main Street after a$6 million reconstruction. Most of the proud owners of historic downtown buildings are local residents who have personally invested millions of dollars into preserving the heart of this city. Partnering with the Oshkosh Area Community Foundation, business owners have invested in remodeling storefront facades. The City of Oshkosh has buried the utility lines to better allow for the skyline of historic buildings and the total vista of an historic district. The Irving-Church Historic District and local-landmark 226 High Avenue, within two to three blocks from the proposed antennae replacements and installations on 530 N. Main Street, also have views of Oshkosh's Downtown historic skyscraper and are distracted because of the present installations and any future conspicuous additions to the roof terrace and observation tower. In January 2017 the City of Oshkosh adopted the Central Mixed Use (CMU) District Building Design Standards (30-245)with architectural guidelines. The present installations on the building's rooftop and tower would never be approved in today's review because of the detrimental visual impact on the building and the surrounding historic district. The Landmarks Commission proposes that no new additions be allowed on the building and as the antennae become obsolete that they would not be replaced. The Landmarks Commission's job is to be vigilant and safeguard the integrity of Oshkosh's architectural heritage and prevent any further compromise to its treasure of historic buildings. The Landmarks Commissioners are in total agreement that the present antennae have compromised the visual impact of the historic skyline and oppose any antennae additions to the building. The Landmarks Commissioners concur that"enough is enough!" Please do not hesitate to contact Steven Wiley, City Staff Liaison to the Landmarks Commission at 920.236.5062 if you have any questions or concerns regarding this letter. Respectfully, Shirley Brabender Mattox Steven D. Wiley City of Oshkosh Landmarks Commission Staff Liaison, Planning Department H'StpRY WISCONSIN copyHISTORICAL S O C I E T Y June 17, 2019 Ms. Tara Cubie Senior Architectural Historian EBI Consulting 6876 Susquehanna Trail South York, PA 17403 Re: 530 North Main Street, Oshkosh, Winnebago County, WI 12975974/W16037/OSHKOSH HOUSING RELO EBI Project#6119000913 E-106 FCC File#0008605149 WHS File#19-0348/WN Dear Ms. Cubie, Thank you for your letter of May 9, 2019 and the accompanying letter from the City of Oshkosh dated April 25, 2019, documenting their strong opposition to the above project. I concur with their assessment that the proposed project would result in an adverse effect on the North Main Street Historic District and the adjacent Irving-Church Historic District. It is important to note that my May 2, 2019 request for a complete list, map and photographs of all historic properties within a 250-foot radius of the proposed undertaking was never provided and, as a result, I was not able to formally comment on the project. If you have any questions, or wish to contact me, please do so via e-mail, leslie.eisenbergCa)wisconsinhistory.org, or via telephone, at 608.264.6507. Sincerely, eslie E. Eisenber , Ph.D., RPA Compliance Arc aeologist Cc: Shirley.Brabender Mattox, City of Oshkosh Landmarks Commission Steven D. Wiley, Staff Liaison, City of Oshkosh Planning Department Collecting,Preserving and Sharing Stories Since 1846 816 State Street Madison,Wisconsin 53706 wisconsinhistory.org EBI Consulting 6876 Susquehanna Trail South York, PA 17403 Tel: (71 7) 428-0401 A environmental I engineering I due diligence www.ebiconsulting.com April 4, 2019 Oshkosh Landmarks Commission/ Historic Preservation c/o Steven Wiley,Assistant Planner 215 Church Avenue 2nd Floor, Room 204 Oshkosh,WI 54901 (920) 236-5062 SWiley(a—)ci.oshkosh.wi.us Subject: Invitation to Comment 12975974/W16037/ OSHKOSH HOUSING RELO 530 North Main Street, Oshkosh,Winnebago County,WI EBI Project#6119000913 Dear Mr.Wiley: Pursuant to Section 106 of the National Historic Preservation Act, the regulations promulgated thereunder and interagency agreements developed thereto, EBI Consulting, Inc. on behalf of AT&T Mobility, LLC provides this notice of a proposed telecommunications facility installation at the address listed above. EBI would like to inquire if you would be interested in commenting on this proposed project. Please refer to the attached project plans for complete details regarding this proposed project. Please note that we are requesting your review of the attached information as part of the Section 106 process only and not as part of the local zoning process. We are only seeking comments related to the proposed project's potential effect to historic properties. Please submit your comments regarding the proposed project's potential effect on historic properties to EBI Consulting,to my attention at 6876 Susquehanna Trail South,York, PA 17403 or contact me via telephone at the number listed below. Please reference the EBI project number. We would appreciate your comments as soon as possible within the next 30 days. Please do not hesitate to contact me if you have any questions or concerns about the proposed project. Respectfully Submitted, Sarah LeVaun Graulty Architectural Historian 802-578-7030 sgraulty(CD_ebiconsulting.com Attachments - Drawings and Maps soott Ave a Scoff Ave rs w _ E Sferlin{t Ave Vit as Ave vC � Y W u � t ° E Llncclfl Rye P N .. .ii..-IrV AVC Fulton Ave y +� ✓ MI N � W" L41 !.Marston PI.. Oshkosh] W Irvin ° E Irvin Ave 41f Irving Ave -111 g Ave �. 9 z Amherst Ave c ❑ale Ave © � v o W9 N e r tf4�E ai K $yc Unaon Ave N Ida Aver _ Oxford Aye � � � Y M W Parkway Ave E Parkway Ave p a a c c E9 to MI W Hudson Ave G /t i1d N c N ati O h� tf�cr C'hr�� q h 4 r r Merritt Aye M i Rye` en m Narlhwezlern Ave y �y a5 Mir b a Washington Ave Washington Ave On a ` sh"wena Ave cQo� aW Seh oof AW.e m 0 v ry v V 0 N {} CE C y r1' alter A-we uuz 4v, f.] Ceape pale 011er AW c C e EBI GIS,Sources:Esri, HERE,Garmin, USGS fl'ritermap,INCREMENT P,ANRCan, Esri Japan, METI, Esri China (Hong Kong), Esri Korea, Esri(Thailand),NGCC, OpenStreetMap contributors,and the GIS User-Community Legend Project Site Site Radius at 250', 500', 1000' and mile Date:3/1/2019 Figure 1 : Site Location Map N 12975974 / W16037 OSHKOSH HOUSING RELO 530 NORTH MAIN STREET OSHKOSH, WI 54901 EBI Consulting PN:6119000913 environmental engineering due diligence � 9 9 9 M 71 A Vf M/yy` All r` - - i IL + r ' 1 ,may r� ., o 24 r� i E--BI IS,Cop ri hit. 2013 Na�,•'alGeographi, SocieAy, i-cubed Legend Project Site Site Radius at 250', 500', 1000' and '/2 mile USGS 24K Quad:Oshkosh,WI 1982 -- Date:3/1/201 9 Figure 2 - Topographic Map IN 12975974 / W16037 OSHKOSH HOUSING RELO 530 NORTH MAIN STREET OSHKOSH, WI 54901 4, EBI Consulting PN:6119000913 � environmental I engineering I due diligence PROJECT INFORMATION AT&T APPROVAL APPLICANT: AT&T SITE ACQUISITION MANAGER: Date 930 NATIONAL PARKWAY SCHAUMBURG, IL 60173 AT&T MASTEC CONSTRUCTION MANAGER: Date FA CODE: 12975974 MASTEC SA PROJECT MANAGER, Date PROPOSED USE: TELECOMMUNICATIONS FACILITY MASTEC SA SPECIALIST: Date STRUCTURE TYPE: ROOF TOP MASTEC COMPLIANCE MANAGER: Date SITE ADDRESS: 530 NORTH MAIN STREET AT&T RF PROJECT MANAGER: Date OSHKOSH, WI 54901 SITE NUMBER: W 16037 AT&T PROJECT MANAGER: Date D PROPERTY OWNER: OSH600KOSH MERRIT HOUSING., AUTORITY AT&T MOBILITY APPROVAL OSHKOSH, WI 54901 CONTACT PERSON: TBD SITE NAME: OSHKOSH HOUSING R E L O Real Estate Date PARCEL NUMBER: 0401220000 RF Date JURISDICTION: WINNEBAGO COUNTY LATITUDE: 44' 1' 13.501" N PROJECT: �C Operation Date LONGITUDE: 88' 32' 14.309" W LTE 5C (AWS) LAT/ LONG TYPE: NAD 83 LTE PROJECT GROUND ELEVATION: 953.1FT MSL PROJECT DESCRIPTION: � � � ❑ POWER COMPANY: MG&E INSTALL (3) NEW AWS RRUS 4426 B66. PHONE: (608) 252-7222 700 AWS 1900 850 WCS FNET TELEPHONE COMPANY: AT&T RELOCATE (3) EXISTING 1900 RRUS32 B2 FROM POS.2 TO ANTENNA POS.3 700 PHONE: (800)-257-0902 DRAWING INDEX REV VICINITY MAP APPLICABLE BUILDING CODES AND STANDARDS W16037-01 TITLE SHEET A DIRECTION: (FROM O'HIARE INTERNATIONAL AIRPORT) CONTRACTOR'S WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE, AND LOCAL CODES AS C WI6037-02 ROOF PLAN A FROM CHICAGO O'HARE AIRPORT:: TAKE THE RAMP ONTO I-190 E, TAKE EXIT 1C FOR I-90 ADOPTED BY THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ) FOR THE LOCATION. THE EDITION OF THE AHJ ADOPTED CODES AND STANDARDS IN EFFECT ON THE DATE OF CONTRACT AWARD SHALL WTOLLWAY TOWARD ROCKFORD, MERGE ONTO 1-90 W, TAKE EXIT 142A ON THE LEFT TO MERGE ONTO W16037-03 ELEVATION A / GOVERN THE DESIGN. US-12 W/US-18 W TOWARD MADISON, TAKE EXIT 259 TOWARD TODD DR, SLIGHT RIGHT ONTO W W16037-04 ANTENNAS LAYOUT A BELTLINE ACCESS RD, SLIGHT LEFT ONTO W BELTLINE FRONTAGE RD, TURN LEFT ONTO TODD DR, TAKE BUILDING CODE: W16037-05 EQUIPMENT LAYOUT A THE 1ST RIGHT ONTO W BELTLINE FRONTAGE RD, TURN LEFT DESTINATION WILL BE ON THE RIGHT, [INTERNATIONAL BUILDING CODE (IBC), 2018 AS ADOPTED BY LOCAL BUILDING AUTHORITY] W16037-06 RRUS SPECIFICATIONS A ARRIVE AT W16037 ELECTRICAL CODE: W16037-07 CONSTRUCTION DETAILS A [NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 70-2002; WI6037-08 ANTENNA MATRIX A 2014 NATIONAL ELECTRICAL CODE, AS ADOPTED BY LOCAL BUILDING AUTHORITY] W16037-09 COAX COLOR CODING A - --- -� LIGHTNING PROTECTION CODE:[NFPA 780 — 2000, LIGHTNING PROTECTION CODE] W16037-10 FIBER-OPTIC JUMPER COLOR CODING A ] ?fig I CONTRACTOR'S WORK SHALL COMPLY WITH THE LATEST EDITION OF THE FOLLOWING STANDARDS. WI6037-11 GENERAL NOTES AI �1^ AMERICAN CONCRETE INSTITUTE (ACI) 318, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC), MANUAL OF STEEL CONSTRUCTION, ASD, NINTH EDITION 1 TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA) 222—H, STRUCTURAL STANDARDS FOR STEEL ANTENNA TOWER AND ANTENNA SUPPORTING STRUCTURES: j 4 TIA 607, COMMERCIAL BUILDING GROUNDING AND BONDING REQUIREMENTS FOR TELECOMMUNICATIONS IIO � " �l INSTITUTE FOR ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) 81, GUIDE FOR MEASURING EARTH a RESISTIVITY, GROUND IMPEDANCE, AND EARTH SURFACE POTENTIALS OF A GROUND SYSTEM B loll' IEEE 1100 (1999) RECOMMENDED PRACTICE FOR POWERING AND GROUNDING OF ELECTRONIC Njrr EQUIPMENT IEEE C62.41, RECOMMENDED PRACTICES ON SURGE VOLTAGES IN LOW VOLTAGE AC POWER CIRCUITS b (FOR LOCATION CATEGORY "C3" AND "HIGH SYSTEM EXPOSURE") _ 4 r TELCORDIA GR-1275, GENERAL INSTALLATION REQUIREMENTS TELCORDIA GR-1503, COAXIAL CABLE CONNECTIONS TO OBTAIN LOCATION OF '+ `sr P WINNEBAGO PARTICIPANTS' UNDERGROUND COUNTY ANSI T1.311, FOR TELECOM — DC POWER SYSTEMS — TELECOM, ENVIRON SALF11PROTECTION FACILITIES BEFORE YOU DIG IN FOR ANY CONFLICTS BETWEEN SECTIONS OF LISTED CODES AND STOPQ )NG .MATERIAL, WISCONSIN. METHODS OF CONSTRUCTION, OR OTHER REQUIREMENTS, THE MOST U SHALL MEMBER GOVERN. WHERE THERE IS CONFLICT BETWEEN A GENERAL RE( A S 1 C�'+,+,, REQUIREMENT THE SPECIFIC REQUIREMENT SHALL GOVERN. • +� SITE QUALIFICATION PARTICIPANTS I HEREBY CERTIFY THAT THESE PLANS WERE PREPARED 4 SATI HK11MAH �A + UNDER MY DIRECT SUPERVISION AND TO THE BEST OFY + L. � � F ■ w III NAME COMPANY NUMBER PROFESSIONAL KNOWLEDGE THEY COMPLY WITH THE REQUIREMENT OF ALL A LVABLE CODES AND ORDINAgES. ■ 15-25581 r +� THESE DRAWINGS ARE PREPARED A/E SATISHKUMAR C. PATEL APEX ENGINEERS, INC. (630) 627-1800 + BASED ON INFORMATION PROVIDED BY ONE CALL SYSTEMS INTERNATIONAL SA MANUEL M. FERRA MASTEC °-0 DOWN RS ` MASTEC NETWORK SOLUTION. GENERAL CALL DIGGERS HOT LINE (847) 463-5957 i1{i ] E+ �;. *; CONTRACTOR TO VERIFY AND ><-soo-2a2-ssu ■t IL .F* TOLL FREE PM LAURA FEHRMAN MASTEC (847 634-4949 DATE: 01/07/19 �+� `■• ■r + � �� INCORPORATE MOST RECENT VERSION FAX A LOCATE 1-800I338— D60 CM MASTEC ) SATISHKUMAR C. PATEL, S.E. #1014 , A OF RFDS PRIOR TO CONSTRUCTION. ( ) WISCONSIN P.E. LICENSE #E-25581 1-800-542-2289 EXPIRES 07-31-2020 Apex Engineers, Inc. OSHKOSH HOUSING RELO AT&T MOBILITY ■_ ST ' Structural & Civil Engineers Lombard, East 22n Street, Suite B SITE NO. 51 037 Network Solutions /� Lombard, Illinois 60148 SITERRA NO. 55185-A � TITLE SHEET AT&T 1351 E. Irving Park Rd Ph. (630) 627 1800 530 NORTH MAIN STREET ` S A 01/07/19 ISSUED FOR REVIEW YA EW SP Itasca, IL 60143 Fax. (630) 627-1165 OSHKOSH, WI 54901 NO. DATE REVISIONS BY CHK APPT DRAWING NUMBER IREVI APEX JOB No. AT02-204 SCALE: AS SHOWN DESIGNED BY: XX DRAWN BY: XX WI6037-01 JI A 6 5 4 3 2 11 x 17 SIZE ANTENNA LEGEND: PICTURES TAKEN ON 1 1/08/2018 a Q o PROPOSED ANTENNA PRIOR TO LTE 4C FNET CONSTRUCTION 1&2 RELOCATED ANTENNA w Iv 04 N Q I 1 IW W 1 SECTOR ALPHA: 0 EXISTING ANTENNA ` D EXISTING CABLE TRAY W/ EXISTING i (6) EXISTING 1/4" COAX JUMPERS. (� PENTHOUSE --- h 1� ----- �___J REMOVED ANTENNA - EXISTING AT&T EQUIPMENT ROOM INSIDE PENTHOUSE. SEE SHEET 05 FOR EQUIPMENT LAYOUT NOTE: ALPHA & GAMMA SECTOR RRUS ARE LOCATED IN EQUIPMENT ROOM. SEE SHEET 05. BETA SECTOR RRUS ARE LOCATED ON PENTHOUSE WALL. SEE SHEET 04. ALPHA SECTOR EXISTING ROOF TOP ELEV. f 103'-6" SECTOR GAMMA: EXISTING (6) EXISTING 1/2" COAX JUMPERS. (4) EXISTING C PENTHOUSE ANTENNAS (TYP.) ---- & [SEE S SHEET 04 FOR DETAILED 04 EXISTING/PROPOSED ANTENNA LAYOUT EXISTING i SECTOR BETA: } 'A& _ �P ELEVATOR EXISTING CABLE TRAY W/ �� r A<: OR G Z I LPENTHOUSE I (6) EXISTING 1/2" COAX JUMPERS, _ R (6) EXISTING DC POWER CABLES & (3) FIBER CABLE TO REMAIN. h\ I two- I I I 1 POSITION 1: EXISTING ANTENNAS ; (3) EXISTING ANTENNAS W/ BETA SECTOR (OTHERS) (TYP.) (3) EXISTING 700 RRUS11 & (3) EXISTING WCS RRUS32 B30 (TYP.1 PER SECTOR) TO REMAIN B POSITION 2: (3) EXISTING ANTENNAS (TYP.1 PER SECTOR) TO REMAIN. RELOCATE (3) EXISTING 1900 RRUS32 B2 TO ANTENNA POS.3 & INSTALL (3) NEW AWS RRUS 4426 B66 (TYP.1 PER SECTOR) POSITION 3: (3) EXISTING ANTENNAS W/ EXISTING (3) EXISTING 700 FNET RRUS 4478 B14 SHARED WITH ANTENNA ' STAIRWELL POS.3 AND ANTENNA POS.4 (TYP.1 PER SECTOR) TO REMAIN. RELOCATE (3) EXISTING 1900 RRUS32 B2 FROM POS.2 TO ANTENNA POS.3 (TYP.1 PER SECTOR) Art I POSITION 4: oz (3) EXISTING ANTENNAS W/ _ (3) EXISTING UMTS 1900 RRUS11 (TYP.1 PER SECTOR) TO REMAIN T DROOF PLAN A SCALE: 1/16"=1'-0" GAMMA SECTOR .,� Apex Engineers, Inc. OSHKOSH HOUSING RELO AT&T MOBILITY ■'1 "� a STe r Structural & Civil Engineers Lombard, East 22n i Street, Suite B SITE NO. 1551 AT&T Network Solutions /� Lombard, Illinois 60148 SITERRA NO. 155185-A � ROOF PLAN 1351 E. Irving Park Rd Ph. (630) 627 1800 530 NORTH MAIN STREET ` S A 01/07/19 ISSUED FOR REVIEW YA EW SP Itasca, IL 60143 Fax. (630) 627-1165 OSHKOSH, WI 54901 IND., DATE REVISIONS BY CHK APPT DRAWING NUMBER AN APEX JOB No. AT02-204 SCALE: AS SHOWN DESIGNED BY: XX DRAWN BY: XX WI6037-02 A 6 5 4 3 2 11 z 17 SIZE NOTE: REFER TO RF DESIGN SHEET/ SCOPING FORM & INSTALL AS REQUIRED DC/FC BOX, XMU, FIBER BOX 6601, DUS41, PATCH PANEL TELECT 5216, BREAKERS & MISC. EQUIPMENT. ALSO, DECOM GSM/UMTS EQUIPMENT/COAX AS SHOWN ON SCOPING FORM. D EXISTING ANTENNAS (OTHERS) (TYP.) NOTE: ANTENNAS TO BE PAINTED A NEUTRAL OL T/ ELEVATOR PENTHOUSE COLOR TO MATCH THE EXISTING BUILDING. T AT&T ANTENNAS SECTOR GAMMA ELEVATION: t138'—O" CONTRACTOR TO WORK WITH BUILDING ELEVATION: 124'-0" ASSOCIATION AND/ OR LANDLORD TO EXISTING ANTENNAS OTHERS TYP. OBTAIN THE APPROPRIATE PAINT COLOR. AT&T ANTENNAS SECTOR GAMMA (OTHERS) ( ) ELEVATION: 120'-0" T n� EXISTING AT&T ANTENNAS / STAIRWELL PENTHOUSE & SEE SHEET 04 FOR ANTENNA LAYOUT T AT&T ANTENNAS SECTOR ALPHA ELEVATION: 1 13'-0" OL T/ PENTHOUSE AT&T ANTENNAS SECTOR ALPHA ® � � ELEVATION: f114'-0" ELEVATION: 109'-0" I I IOIL U AT&T ANTENNAS SECTOR BETA ROOF TOP ELEVATION: 100'-0" ELEVATION: t103'-6" B B B B B B B L"B B B C B B B B B B B B B B BB B B BB B B B B B B B B B B B B B H— E] B B B B B B-- B B B B B B B B B B B B B B B B B B B B B B B H— E] B B B B B B B B B HHHH An, inn nnn n n n n nnnn- El U1 OL FINISHED GRADE ELEVATION: 0'-0" DELEVATION A SCALE: 3/64"=1'-0" .,� Apex Engineers, Inc. OSHKOSH HOUSING RELO AT&T MOBILITY ■'1 "A a STe r Structural & Civil Engineers Lombard, East 22n Street, Suite B SITE NO. 51 037 Network Solutions /� Lombard, Illinois 60148 SITERRA NO. 55185-A � ELEVATION AT&T 1351 E. Irving Park Rd Ph. (630) 627 1800 530 NORTH MAIN STREET ` S A 01/07/19 ISSUED FOR REVIEW YA EW SP Itasca, IL 60143 Fax. (630) 627-1165 OSHKOSH, WI 54901 NO. DATE REVISIONS BY CHK PPT DRAWING NUMBER REV APEX JOB No. AT02-204 SCALE: AS SHOWN DESIGNED BY: XX DRAWN BY: XX W16037-03 A 6 5 4 3 2 11 x 17 SIZE NOTE: EXISTING ANTENNA MODELS, POSITIONS & AZIMUTHS ARE GC TO VERIFY RELOCATION OF ANTENNAS ASSUMED BASED ON RFDS. CONTRACTOR TO VERIFY RELOCATE/ ADD/ REPLACE MOUNTING PIPES AS POS.1 & POS.2 TO BRACKET, INSTALLATION & PRIOR TO CONSTRUCTION & COORDINATE WITH AT&T RF REQUIRED TO ACCOMMODATE NEW ANTENNAS LOCATION OF 700 FNET RRUS 4478 B14 IN ENGINEER FOR ANY DISCREPANCY. EACH SECTOR DURING LTE 4C FNET Q CONSTRUCTION (TYP. ALL SECTORS) REFER TO RF DESIGN SHEET FOR ADDITIONAL = = INFORMATION ON TMA'S/DIPLEXERS/DC&FIBER BOX/SQUID . Q� Q� _ POSITION 4: o POSITION 4: O D (3) EXISTING ANTENNAS COMMSCOPE SBNHH-1 D65C (96"x1 1.9"x7.1") W/ D U LTE 700 LTE FNET FNET 700 (3) EXISTING ANTENNAS U LTE 700 LTE FNET 700 FNET 700 Ld N LTE WCS 1900 700 UMTS 1900 COMMSCOPE SBNHH-1 D65C (96"x1 1.9"x7.1") W/ N Q LTE WCS AWS LTE 1900 UMTS lsoo (3) EXISTING UMTS 1900 RRUS11 (TYP.1 PER SECTOR) TO REMAIN N Q POS.1 POS.2 POS.3 POS.4 POSH POS.2 POS.3 POS (3) EXISTING UMTS 1900 RRUS11 (TYP.1 PER SECTOR) POSITION 3: POSITION 3: (3) EXISTING ANTENNAS COMMSCOPE SBNHH-1 D65C (96"x1 .1 1.9"x7 ") W/ 11 (3) EXISTING ANTENNAS (3) EXISTING 700 FNET RRUS 4478 B14 SHARED WITH ANTENNA POS.3 AND ANTENNA POS.4 (TYP.1 PER SECTOR) TO REMAIN. COMMSCOPE SBNHH-1 D65C (96"x1 1.9"x7.1") W/ RELOCATE (3) EXISTING 1900 RRUS32 B2 (3) EXISTING 700 FNET RRUS 4478 B14 SHARED WITH EXISTING FROM POS.2 TO ANTENNA POS.3 (TYPA PER SECTOR) EXISTING ANTENNA POS.3 AND ANTENNA POS.4 (TYP.1 PER SECTOR) PENTHOUSE PENTHOUSE POSITION 2: POSITION 2: (3) EXISTING ANTENNAS COMMSCOPE SBNHH-1 D65C (3) EXISTING ANTENNAS (96"x1 1.9"x7.1") (TYP.1 PER SECTOR) TO REMAIN. COMMSCOPE SBNHH-1 D65C (96"x1 1.9"x7.1") W/ RELOCATE (3) EXISTING 1900 RRUS32 B2 TO ANTENNA POS.3 & (3) EXISTING 1900 RRUS32 B2 (TYPA PER SECTOR) INSTALL (3) NEW AWS RRUS 4426 B66 (TYP.1 PER SECTOR) (3) EXISTING RAYCAP POSITION 1: (3) EXISTING RAYCAP POSITION 1: DC6-48-60-18-8C (3) EXISTING ANTENNAS DC6-48-60-18-8C TO REMAIN (3) EXISTING ANTENNAS COMMSCOPE SBNHH-1 D65C (96"x1 1.9"x7.1") W/ COMMSCOPE SBNHH-1 D65C (96"x1 1.9"x7.1") W/ (3) EXISTING 700 RRUS11 & (3) EXISTING 700 RRUS11 & (3) EXISTING WCS RRUS32 B30 (TYP.1 PER SECTOR) TO REMAIN C (3) EXISTING WCS RRUS32 B30 (TYP.1 PER SECTOR) G�2 BETA SECTOR: o BETA SECTOR: °s,o'oo V) (1) EXISTING 700 FNET RRUS 4478 B14, 3?000 �U) (1) EXISTING 700 FNET RRUS 4478 B14, °° T �W (1) EXISTING 700 RRUS11, <�2 "� (1) EXISTING 700 RRUS11, b (1) EXISTING 1900 RRUS32 B2, oF� N (1) EXISTING 1900 RRUS32 B2, °`1'0 �52 u=), (1) EXISTING WCS RRUS32 B30 & �o°o � (1) EXISTING WCS RRUS32 B30 & (1) EXISTING UMTS 1900 RRUS11 (1) EXISTING UMTS 1900 RRUS11 MOUNT ON PENTHOUSE WALL < MOUNT ON PENTHOUSE WALL TO REMAIN O��G 2ppP 6W\ R�2�P �� SFc��� <AF EXISTING S�G��� q�F EXISTING BETA SECTOR: '� $ Pti 4-- o ELEVATOR ELEVATOR o P �4--0o PENTHOUSE ins° PENTHOUSE INSTALL (1) NEW AWS RRUS 4426 B66 MOUNT ON PENTHOUSE WALL. SEE SHEET 07/3 B EXISTING ANTENNAS EXISTING ANTENNAS (OTHERS) (TYP.) (OTHERS) (TYP.) ALPHA & GAMMA SECTORS: ALPHA & GAMMA SECTORS: Q. (2) EXISTING 700 FNET RRUS 4478 B14, z (2) EXISTING 700 FNET RRUS 4478 B14, ^moo^ (2) EXISTING 700 RRUS11, (2) EXISTING 700 RRUS11, ��"�o`' 2 EXISTING 1900 RRUS32 B2, (2) EXISTING 1900 RRUS32 B2, "¢ (2) EXISTING WCS RRUS32 B30 & (2) EXISTING WCS RRUS32 B30 & v03 (2) EXISTING UMTS 1900 RRUS1 1 �Q�� (2) EXISTING UMTS 1900 RRUS11 o ¢° TYP.1 PER SECTOR ARE LOCATED IN ¢ SF (TYP.1 PER SECTOR) ARE LOCATED IN ( ) EQUIPMENT ROOM TO REMAIN. o00 EQUIPMENT ROOM. q�/M /i'B INSTALL (2) NEW AWS RRUS 4426 866 IN ,C§ SF SEE SHEET 05 EQUIPMENT LAYOUT. ¢200� h' /FTq EQUIPMENT ROOM (TYPA PER SECTOR) ¢_�"¢°" gZjCTOR ^0000 ¢° ��° SEE SHEET 05 EQUIPMENT LAYOUT. ^0000 M�Ty 9Frq 2 EXISTING ANTENNA LAYOUT r. PROPOSED ANTENNA LAYOUT �Q� A SCALE: N.T.S. J SCALE: N.T.S. J Apex Engineers, Inc. OSHKOSH HOUSING RELO AT&T MOBILITY ■_ A a ST e r Structural & Civil Engineers Lombard, East 22n Street, Suite B SITE NO. Network Solutions /� Lombard, Illinois 60148 SITERRA NO. 155185-A � ANTENNA LAYOUT AT&T 1351 E. Irving Park Rd Ph. (630) 627 1800 530 NORTH MAIN STREET ` S A 01/07/19 ISSUED FOR REVIEW YA EW SP Itasca, IL 60143 Fax. (630) 627-1165 OSHKOSH, WI 54901 NO. DATE REVISIONS BY CHK PPT DRAWING NUMBER REV APEX JOB No. AT02-204 SCALE: AS SHOWN DESIGNED BY: XX DRAWN BY: XX WI6037-04 A 6 5 4 3 2 11 z 17 W SIZE NOTES: 1. EXISTING SPACE FOR PROPOSED EQUIPMENT ASSUMED TO BE ADEQUATE, PRIOR TO FINAL BBU CONFIGURATION: INSTALLATION, COORDINATE FINAL LOCATION WITH CONSTRUCTION MANAGER. (1) EXISTING 6630, (1) EXISTING RBS 6601 & 2. COORDINATE WITH CONSTRUCTION MANAGER FOR THE PROVISION OF DC CIRCUIT (3) EXISTING RAYCAP DC12-48-60-RM TO REMAIN. (1) EXISTING XMU. BREAKERS AND OTHER ANCILLARY ITEMS TO SUPPORT THE NEW EQUIPMENT. ADD (3) NEW 30 AMP 3. PROPERLY BOND ALL EQUIPMENT AND CONDUCTIVE SURFACES TO EXISTING GROUND PER NEC AND AT&T STANDARDS. DECOM UMTS/GSM AS SHOWN ON SCOPING FORM. 12'-3" D WCS WCS 700 1900 X --T===T===T== -__ -__ ___--_ -___- -T---- ---- o (4) RRI�S 2) UM z W EXISTING AT&T a RRUS III 50 ROOFTOP COAX ca r I I I I I I I I I I ENTRY HOOD o II rn z II N ww - -- ---- ALPHA & GAMMA SECTORS: hI hF (2) EXISTING 700 FNET RRUS 4478 B14, 3'-0" (2) EXISTING 700 RRUS11, `O EXIST (2) EXISTING WCS RRUS32 B30 & C LTEII RACK (2) EXISTING UMTS 1900 RRUS11 LING V, (TYPA PER SECTOR) TO REMAIN. F z o 0 I j 3 LO ZD I af 3 � a IF== =�1 II II II I -EXISTING o ALPHA & GAMMA SECTORS: FIFI,RACK -- - INSTALL (2) NEW AWS RRUS 4426 B66 (TYP.1 PER SECTOR) - --- --- --- --- --li---- --II- --- --- --- --II- -- --II- --- -- I -- ---------------- il -`° 11 B -- --- --- --- ---I* —I h �XISTING EXISTING in BATTERY RACK =1=_=i- = DC POWER = i=_=i=_=i=_=i=_=i=- i=_=L PLANT zz (2) RRUS N a X 1900 1900 u'a 1'-0" 2'-2" 2'-0" 2'-2" 5'-0" 2'-2" 9" ALPHA & GAMMA SECTORS: (2) EXISTING 1900 RRUS32 B2 15'-3" (TYP.1 PER SECTOR) TO REMAIN. EQUIPMENT LAYOUT A SCALE: 3/8"=1'-0" .,� Apex Engineers, Inc. OSHKOSH HOUSING RELO AT&T MOBILITY ■'1 A a STe Structural & Civil Engineers Lombard, East 22n i Street, Suite B SITE NO. 1551 AT&T Network Solutions /� Lombard, Illinois 60148 SITERRA NO. 155185-A � EQUIPMENT LAYOUT 1351 E. Irving Park Rd Ph. (630) 627 1800 530 NORTH MAIN STREET ` S A 01/07/19 ISSUED FOR REVIEW YA EW SP Itasca, IL 60143 Fax. (630) 627-1165 OSHKOSH, WI 54901 NO. DATE REVISIONS BY CHK PP' DRAWING NUMBER REV SCA APEX JOB No. AT02-204 LE AS: SHOWN DESIGNED BY: XX DRAWN BY: XX WI6037-05 A 6 5 4 3 2 11 x 17 SIZE RRUS 32 B2 RRUS 32 B30 RRUS 32 B66 PCs WCS A+B blocks AWS TX = 1930 - 1990 MHz - TX = 2350 - 2360 MHz - TX = 2110 - 2180 MHz RX = 1850 - 1910 MHz - RX = 2305 - 2315 MHz - RX = 1710 - 1780 MHz frig, ■ CPRI 2 ports x 10 Gbps. Install 2 SFPs and connect 2 fiber CPRI 2 ports x 10 Gbps CPRI 2 ports x 10 Gbps. Install 2 SFPs and connect 2 fiber pairs to the RRUS32 during initial install. Only use Ericsson supplied and approved SFPs pairs to the RRUS32 during initial install. Only use Ericsson supplied and approved SFPs, RDH10247/3 6 external alarm inputs Only use Ericsson supplied and approved SFPs RDH10247/3 6 external alarm inputs Max wind load @ 50m/sec = 350N 6 external alarm inputs Max wind load @ 50m/sec = 350N Breaker size = 20A, DC Power Consumption = Max wind load 0 50m/sec = 350N RRUS RRUS + PSU RRUS + A2 EXPANSION DUAL Breaker size = 30A, DC Power Consumption = 91OW (for 800W Breaker size = 30A, DC Power Consumption = 88OW (for RRUS SUPPORT dimensioning) ) 200mm horizontal separation required for side by dimensioning) > 200mm horizontal separation required for side by side side mounting I 200mm horizontal separation required for side by side CLAMP MOUNTING RANGE TUBES SQUARE PROFILES 90' ANGLE 200mm separation required for antenna backplane mounting mounting 200mm separation required from antenna backplane to radio to radio 200mm separation required from antenna backplane to radio P q P P q P 025mm 35x35mm 35x35mm 600mm 800mm vertical outdoor indoor separation required 600mm/800mm vertical outdoor/indoor separation 600mm 800mm vertical outdoor indoor separation required MINIMUM / / P q / / P q (1,0 in) (1,4 x 1,4 in) (1,4 x 1,4 in) Min, Max DC cable size from squid to radio = 10, required Min, Max DC cable size from squid to radio = 10,8 AWG 8 AWG Max DC cable size from squid to radio = 8AWG _ Adapter is required for 2-wire connection Adapter is required for 2-wire connection - Adapter is required for 2-wire connection - Shielded DC cable is required 0114 mm 80 x 80 mm 80 x 80 mm Shielded DC cable is required Shielded DC cable is required Ground cable size = 2AWG MAXIMUM (4,5 in) (3,2 x 3,2 in) (3,2 x 3,2 in) Ground cable size = 2AWG > Ground cable size = 2AWG ' > Dimensions (incl. handles, feet and sunshield) Dimensions (incl. handles, feet and sunshield) _ HOT DIP GALVANIZED STEEL BRACKET l I 11 Dimensions (incl. handles, feet and sunshield) - - Height: 27.2" (690 mm) Height: 27.2" 690 mm Height: 27.2" (690 mm) 9 ( ) Width: 12.1" (306 mm) - MATERIAL: S355MC FZV, FASTENERS 8.8 FZV OR EQUIVALENT Width: 12.1" (306 mm) Width: 12.1" (306 mm) - Depth: 7.0" (178 mm) - MINIMUM 70 UM ZINC COATING, DESIGNED FOR >20 YEARS CORROSION-FREE Depth: 7.0" 178 mm - Depth: 7.0" (178 mm) Weight, excl. mounting hardware = 53 Ibs 24 k P ( ) Weight, excl. mounting hardware = 53 Ibs 24 k 9 9 ( 9) - DESIGNED TO 67 M/S WIND SPEED REQUIREMENT (150 MPH) > Weight, excl. mounting hardware = 53 Ibs (24 kg) g 9 ( 9) SUPPORTS RRUW/RRUS01 , RRUS 1 1/12, RRUS32 SPECIFICATIONS RRUS32 WITH RRUSA2 OR PSU SCALE: N.T.S. - SXK1091946/1 FOR FIRST RRUS & SXK109146/2 TO ADD SECOND RRUS RRUS BRACKET SXK1091946/1 & SXK1091946/2 SPECIFICATION C L - RRUS 4478 B5 RRUS 4415 B25 RRUS 4415 B66 RRUS 4426 B66 SCALE: N.T.S. B25 B66 • 65 -TX -TX -TX RADIO 4449 DUAL BAND -TX = 869 -894 MHz -TX = 1930 -1995 MHz -TX = 2110 -2180 MHz -TX = 2110 -2180 MHz -RX = 824 -849 MHz -RX = 1850 -1915 MHz -RX = 1710 -1780 MHz -RX = 1710 -1780 MHz B5 & B12 • CPRI 2 ports x 2.5/4.9/9.8/10.1 Gbps. CPRI 2 ports x 2.5/4.9/9.8/10.1 CPRI 2 ports x 2.5/4.9/9.8/10.1 CPRI 2 ports x 2.5/4.9/9.8/10.1 Install 2 SFPs and connect 2 fiber pairs Gbps. Install 1 SFP and connect 1 Gbps. Install 1 SFP and connect 1 Gbps. Install 2 SFP7s and connect 2 4TX/4RX per Band (B5 & B12) to the RRUS 4478 during initial install. fiber pair to the RRUS 4415 during fiber pair to the RRUS 4415 during fiber pair to the RRUS 4426 during 320 W of total power • Only use Ericsson supplied and approved initial install. initial install. initial install. - 4x40 W per band (4T4R in each band) SFPs Only use Ericsson supplied and Only use Ericsson supplied and Only use Ericsson supplied and Full IBW in each band - 2x SFP3 RDH 10247/25 for cellular A approved SFPs RDH10265/25 approved SFPs RDH10265/25 approved SFP7s RDH10265/25 Carrier BW: - 5, 10 MHz OR B block 2 external alarm inputs 2 external alarm inputs - Install 2 SFP RDH 10265/3 for LTE: Max 6 carriers per port (DL), max 6 - 2xSFP7 RDH 10265/25 for cellular A Max wind load 0 50m/sec = Max wind load 0 50m/sec = CPRI length 1.4 km -10 km carriers per port (UL) AND B block 260N 26ON - Install SFP7 (pair): RDH 102 70/1 CPRI Support: -2.5 ; 4.9; 9.8; 10.1 - Exception cases: Breaker size = 20A, DC Power Breaker size = 20A, DC Power and RDH 102 70/2(bi-directional - 48 VDC 3-wire (2-wire with adapter) 2xSFP7 RDH 10265/3 for CPRI Length Consumption = 670 W (for Consumption = 670 W (for SFP7 for CPRI length > 10 km - Two DC power ports of - 20A 1.4 -10km dimensioning) dimensioning) 2 external alarm inputs AISG TMA & RET support via IRS-485 or RF 2xSFP7 RDH 10270/1 & RDH 10270/2 200mm horizontal separation 200mmhorizontal separation Max wind load 0 50m/sec = 260N connectors RRUS 4478 B 14 for CPRI length > 10km required for side by side mounting required for side by side mounting Breaker size = 25A, DC Power ' - Bias-T only be supported on antenna port A • B14 2 external alarm inputs 200mm separation required from 200mm separation required from Consumption = 670 W (for and C. -TX = 758 -768 MHz Max wind load 0 50m/sec = 260N g antenna backplane to radio antenna backplane to radio dimensioning) Four antenna connectors: 4 x 4.3-10 plus (f) -RX = 788 -798 MHz Breaker size = 25A, DC Power 400mm vertical outdoor/indoor 400mm vertical outdoor/indoor . 200mmhorizontal separation required 2 external alarm • CPRI 2 ports x 2.5/4.9/9.8/10.1 Gbps. Consumption = 805W (for dimensioning) separation required between 2 separation required between 2 for side by side mounting - 73 lb. B Install 1 SFP and connect 1 fiber pair to 200mmhorizontal separation required for radios radios . 200mmseporation required from - 33L (14.96" x 13.19" x 10.43") (Preliminary, the RRUS 4478 during initial install. side by side mounting 500mm vertical separation below 500mm vertical separation below antenna backplane to radio final figures in Mar 18 pending B12 filter design) • Only use Ericsson supplied and approved 200mmseparation required from antenna antenna antenna 400mmvertical outdoor/indoor IP 65, -40 to +55 'C SFPs RDH10265/25 backplane to radio Min, Max DC cable size from squid Min, Max DC cable size from squid separation required between 2 radios • 2 external alarm inputs 400mmvertical outdoor/indoor separation to radio = 10,8 AWG to radio = 10,8 AWG . 500mmvertical separation below RADIO 8843 DUAL BAND B2 & B66A • Max wind load 0 50m sec = 260N required between 2 radios -Adapter is required for 2-wire -Adapter is required for 2-wire antenna / connection connection 4TX/4RX per Band (62 & B66A) • Breaker size = 25A, DC Power Min, Maxertical separation below antenna Min, Max DC cable size from squid 320 W of total power with three configuration options Consumption = 670 W for dimensioning) Min, Ma DC cable size from squid to -Shielded DC cable is required -Shielded DC cable is required to radio = 10,8 AWG P g P P ( 9) Ground cable size = 2AWG Ground cable size = 2AWG - 4x40 W per band (4T4R in each band) • 200mm horizontal separation required for radio = 10,8 AWG -Adapter is required for 2-wire P q _ - Or 4x20W for 82 and 4x60W for B66A side b side mounting Adapter is required for 2-wire Dimensions (incl. handles, feet and Dimensions (incl. handles, feet and connection y 9 connection sunshield, w/o fan unit) sunshield, w/o fan unit) -Shielded DC cable is required - Or 2x60W for B2 and 2X8DW for B66A (2T4R in each band) • 200mm separation required from antenna Full IBW in each band backplane to radio Shielded DC cable is required -Height: 14.96" (380 mm) -Height: 14.96" (380 mm) Ground cable size = 2AWG P Ground cable size = 2AWG Carrier Maxc 5, s 15,port MHz • 400mm vertical outdoor indoor separation -Width: 13.19" (335 mm) -Width: 13.19" (335 mm) Dimensions (incl. handles, feet and • / P Dimensions Incl. handles, feet and LTE: x 3 carriers per port (DL), max 3 carriers per port (UL) required between 2 radios ( -Depth: 5.39" (137 mm) -Depth: 5.39" (137 mm) sunshield, w/o fan unit) • q CPRI Support: -2.5; 4.9; 9.8; 10.1 • 500mm vertical separation below antenna sunshield, w/o fan unit) Weight, excl. mounting hardware = Weight, excl. mounting hardware = -Height: 14.96"(380 mm) -4g VDC 3-wire (2-wire with adapter) • Min, Max DC cable size from squid to - Height: 16.5" (420 mm) 46 Ibs (21 kg) 46 Ibs (21 kg) -Width: 13.19"(335 mm) - Two DC power ports of with radio = 10,8 AWG - Width: 13.4" (340 mm) -Depth: 5.8"(147. mm) AISG TMA & RET support via RS-485 or RF connectors -Adapter is required for 2-wire connection - Depth: 7.7' (196 mm) Weight, excl. mounting hardware = - Bias-T only be supported on antenna port A and E. -Shielded DC cable is required Weight, excl. mounting hardware = 59.9 48.4 Ibs (22 kg) Eight antenna connectors: 8 x 4.3-10 plus (f) • Ground cable size = 2AWG Ibs (27.2 kg) - 4 ports dedicated to 82 and 4 ports dedicated to B66A • Dimensions (incl. handles, feet and sunshield, w/o fan unit) 2 75extellb. alarm -Height: 16.5" (420 mm) -36L (14.96" x 13.19" x 11.1") -Width: 13.4" (340 mm) IP 65, -40 to +55 'C -Depth: 7.7" (196 mm) RRUS SPECIFICATIONS A • Weight, excl. mounting hardware = 59.9 J 4 RRUS D B SPECIFICATIONS Ibs (27.2 kg) SCALE: N.T.S. SCALE: N.T.S. Apex Engineers, Inc. OSHKOSH HOUSING RELO AT&T MOBILITY ■_ A a ST e. Structural & Civil Engineers Lombard, East 22n Street, Suite B SITE NO. 1551 Network Solutions /� Lombard, Illinois 60148 SITERRA NO. 155185-A � RRUS SPECIFICATION AT&T 1351 E. Irving Park Rd Ph. (630) 627 1800 530 NORTH MAIN STREET ` S A 01/07/19 ISSUED FOR REVIEW YA EW SP Itasca, IL 60143 Fax. (630) 627-1165 OSHKOSH, WI 54901 NO. DATE REVISIONS BY CHK APPT DRAWING NUMBER IREVI APEX JOB No. AT02-204 SCALE: AS SHOWN DESIGNED BY: XX DRAWN BY: XX WI6037-06 I A 6 5 4 3 2 11 x 17 SIZE FEATURES: FEATURES: PROVIDES SIMPLIFIED CONNECTIVITY AND CABLE PROVIDES PROTECTION FOR TWO (2) 48 VDC CIRCUITS * MANAGEMENT FOR DC POWER AND FIBER OPTIC CABLES, OFFERING A CENTRAL * ROBUST DC SURGE PROTECTION OF 60 KA 8/20 MS POINT OF CONNECTIVITY DESIGNED FOR ROOF-TOP INSTALLATIONS OF REMOTE * IEC 61643-1 CLASS II PROTECTION * RADIO HEADS (RRH) OR DISTRIBUTED NODEB SYSTEMS CONNECTS 12 PAIR OF * NEMA 4 RATED ENCLOSURE FIBER AND 6 DC POWER * FORM C RELAY CONTACTS * CIRCUITS FLEXIBLE DESIGN UTILIZES A NEMA 4 ENCLOSURE, * SUPPRESSOR STATUS ALARM FEATURES NEW 1/2"0 HILTI HIT-HY * ALLOWING FOR INDOOR OR OUTDOOR INSTALLATION ON A ROOF OR TOWER TOP NEW UNISTRUT P1000 ENCLOSURE IS RATED FOR -40' C TO +80' C 10.38" 20 AT 3'-0" O.C. TYP RAILS W/ )�"0 HILTI * " INPUT FOR CONDUIT AND THREE 2 " ONE 2�j� (3) BOLTS PER RAIL. HIT-HY 20 W/6" MIN OUTPUTS FOR SECTOR DISTRIBUTION (263.31 mm) EMBEDMENT (TYP.) 10.25" 6.29" NEW UNISTRUT 16.245" P1000k D (260.30mm) (159.87mm) OR (412.61 mm) 8" 6 20" NEW RRUS 16.10" 6.642" 00.313" 168.70mm L (203.20mm) (157.40mm)(794mm) (408.89mm) O O 4 PLACES) 14" D 6.586" (355.60mm) 167.28mm E ° E E ��� r O N M O 0 O O r O (o ON) E io E o E N N N vi W O 6 ® A M 4 L6 07 M n M EXISTING WALL ail 00.313" (7.94mm) (4 PLACES) FC12 CENTRAL FIBER OPTIC & 2 DC2 SECTOR FIBER & 3 RRUS MOUNT DETAIL C DC POWER CONNECTION POWER DISTRIBUTION BOX SCALE: NTS FIBER BUNDLE 44' DOME COVER HANGER ADAPTER GROMMET SECURING BAND ROSENBERGER PART NO. CX608-HAO711 (OR EQUIVALENT) AIR VALVE HANGER ADAPTER GROMMET PART DC CABLE NO.CX608-HA1720 BUNDLE TOP VIEW (OR EQUIVALENT) RAYCAP DC6 OVER 9" VOLTAGE PROTECTOR DOME COVER 9" O O RAYCAP SUPPLIED DOME COVER SECURING BAND FOR ATTACHING DOME SECURING BAND N B COVER TO DC6 OVER N VOLTAGE PROTECTOR CLIP LUGS FOR ATTACHING DEVICE TO BASE ASSEMBLY SNAP-IN HANGER OVAL CABLE INGRESS PORT ROSENBERGER PART NO. DOUBLE CLAMP 10" POWER CABLE TH495-DC-78 PART NO. 0 (OR EQUIVALENT) TH496-DC114 PORTS (TYP) INGRESS SIDE VIEW OVAL CABLE INGRESS PORT SNAP-IN HANGER DOUBLE CLAMP POWER CABLE INGRESS PORT POWER CABLE PORT (TYP 6) NOTES: FIBER SIDE 1. REFER TO JSA DOCUMENT FOR EXACT CABLE MODEL NUMBERS AND POWER SIDE MANUFACTURER SPECIFICATIONS FOR PROPER GROMMETS AND CLIP LUGS FOR ATTACHING OVAL CABLE INGRESS PORT HANGERS TO SUPPORT THE FIBER AND DC CABLE BUNDLES. DEVICE TO BASE ASSEMBLY 2. REFER TO STRUCTURAL ANALYSIS FOR EXACT CABLE ROUTING AND (TYP 4) MOUNTING CONFIGURATION. FIBER CABLE SUPPORT RAYCAP DC6-48-60-18-8C A 4 SCALE: NTS 5 DC POWER OVER VOLTAGE PROTECTOR (OVP) Apex Engineers, Inc. OSHKOSH HOUSING RELO AT&T MOBILITY ■_n A a ST e Structural & Civil Engineers Lombard, East 22n i Street, Suite B SITE NO. 1551 AT&T Network Solutions /� Lombard, Illinois 60148 SITERRA NO. 155185-A � CONSTRUCTION DETAILS 1351 E. Irving Park Rd Ph. (630) 627 1800 530 NORTH MAIN STREET ` S A 01/07/19 ISSUED FOR REVIEW YA EW SP Itasca, IL 60143 Fax. (630) 627-1165 OSHKOSH, WI 54901 NO. DATE REVISIONS BY CHK APPT DRAWING NUMBER REV APEX JOB No. AT02-204 SCALE: AS SHOWN DESIGNED BY: XX DRAWN BY: XX WI6037-07 A 6 5 4 3 2 11 z 17 SIZE Of ANTENNA COAXIAL FEEDER ANTENNA TOP AND BOTTOM ANTENNA ANTENNA TMA/ RRU MECHANICAL ELECTRICAL CENTERLINE ANTENNA ANTENNA NUMBER POLARITY/PORT JUMPER COLOR MODEL NUMBER VENDOR MODEL NUMBER AZIMUTH DOWNTILT DOWNTILT GFROUND TIP HEIGHT SIZE LENGTH TYPE 700 (1) RRUS11 LTE 700 Al FSBNHH-1 D65C COMMSCOPE 0' — — 109'—O" 113'-0" FIBER ±50' WCS (1) RRUS32 B30 LTE WCS D AWS = A2 �_ z SBNHH-1D65C COMMSCOPE (1) RRUS 4426 B66 Or — — 109'-0" 113'-0" FIBER ±50' LTE AWS 3: 0 A 1-- (1) RRUS 4478 B14 FNET 700 z SHARED W/FNET ANTENNA POS. #4 FNET 700 A3 LLB SBNHH-1 D65C COMMSCOPE 0� — — 109'-0" 113'-0" FIBER t50' 1900 1 (1) RRUS32 B2 LTE 1900 W � FNET 700 z SHARED W/FNET RRUS 4478 B14 FNET 700 A4 — SBNHH-1 D65C COMMSCOPE POS. #3 0' — — 109'-0" 113'-0" FIBER ±50' 1900 0 (1) RRUS11 UMTS 1900 Q:� I-- 700 (1) RRUS11 LTE 700 B1 � SBNHH-1 D65C COMMSCOPE 120' — — 100'-0" 104'-0" FIBER ±130' WCS z 0 (1) RRUS32 B30 Q � LTE WCS AWS 0 0— C B2 U SBNHH-1D65C COMMSCOPE (1) RRUS 4426 B66 120' — — 100'-0" 104'-0" FIBER ±130' LTE AWS — � W B 0 FNET 700 O J Q (1) RRUS 4478 B14 z SHARED W/FNET ANTENNA POS. #4 FNET 700 83 0 Q SBNHH-1D65C COMMSCOPE 120' — — 100'-0" 104'-0" FIBER ±130' 1900 U � (1) RRUS32 62 LTE 1900 FNET 700 L z SHARED W/FNET RRUS 4478 B14 FNET 700 64 0 SBNHH-1 D65C COMMSCOPE POS. 3 120' — — 100'-0" 104'-0" FIBER ±130' 1900 W 1-- (1) RRUS11> UMTS 1900 700 0 11� (1) RRUS11 LTE 700 C1 I-- SBNHH-1D65C COMMSCOPE 240' — — 120'-0" 124'-0" FIBER ±90 WCS U) (1) RRUS32 B30 LTE WCS � z AWS O O B C2 Q SBNHH-1D65C COMMSCOPE (1) RRUS 4426 B66 240' — — 120'-0" 124'-0" FIBER ±90 LTE AWS (1) RRUS 4478 B14 FNET 700 z Q FNET 700 SHARED W/FNET ANTENNA POS. #4 C3 0 SBNHH-1D65C COMMSCOPE 240° — — 120'-0" 124'-0" FIBER ±90 1900 U (1) RRUS32 B2 LTE 1900 FNET 700 SHARED W/FNET RRUS 4478 B14 FNET 700 C4 SBNHH-1D65C COMMSCOPE POS. #3 240' — — 120'-0" 124'-0" FIBER ±90 1900 (1) RRUS11 UMTS 1900 ANTENNA MATRIX IS PREPARED BASED ON INFORMATION PROVIDED BY MASTEC NETWORK SOLUTION. GENERAL CONTRACTOR TO VERIFY AND INCORPORATE MOST RECENT VERSION OF RFDS PRIOR TO CONSTRUCTION. ANTENNA MATRIX A (D NTS ■'1 .A, Apex Engineers, Inc. OSHKOSH HOUSING RELO AT&T MOBILITY ST Structural & Civil Engineers Lombard, East 22n Street, Suite B SITE NO. Network Solutions /� Lombard, Illinois 60148 SITERRA NO. 155185-A � ANTENNA MATRIX AT&T 1351 E. Irving Park Rd Ph. (630) 627 1800 530 NORTH MAIN STREET ` S A 01/07/19 ISSUED FOR REVIEW YA EW SP Itasca, IL 60143 Fax. (630) 627-1165 OSHKOSH, WI 54901 NO. DATE REVISIONS BY CHK APPT DRAWING NUMBER REV APEX JOB No. AT02-204 SCALE: AS SHOWN DESIGNED BY: XX DRAWN BY: XX WI6037-08 A 6 5 4 3 2 11 x 17 SIZE CABLE MARKING COLOR CONVENTION TABLE FIGURE 1 : ANTENNA ORIENTATION Al-1 Al-2 A2-1 A2-2 A3-1 A3-2 A4-1 A4-2 AT&T ALPHA, A, X, #1 +45 -45 +45 -45 +45 -45 +45 -45 SECTOR RED RED RED RED RED RED RED RED C4 Al Your world. Delivered. ANTENNA WHITE WHITE ORANGE ORANGE BROWN BROWN VIOLET VIOLET PORT (+/-) SLATE BROWN SLATE BROWN SLATE BROWN SLATE BROWN Version 2.8 — Updated 5/28/2014 ORANGE / ORANGE / ORANGE / ORANGE / ORANGE / ORANGE / ORANGE / ORANGE / BAND (LOW/HI) *SEE NOTES 13 AND 15 D VIOLET VIOLET VIOLET VIOLET VIOLET VIOLET VIOLET VIOLET SLATE / SLATE / SLATE / SLATE / SLATE / SLATE / SLATE / SLATE / BEAM (LEFT/RIGHT) *SEE NOTE 14 BELOW YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW 61-1 B1-2 B2-1 B2-2 B3-1 B3-2 64-1 B4-2 BETA, B, Y, #2 +45 -45 +45 -45 +45 -45 +45 -45 C1 A4 SECTOR BLUE BLUE BLUE BLUE BLUE BLUE BLUE BLUE ANTENNA WHITE WHITE ORANGE ORANGE BROWN BROWN VIOLET VIOLET B4 131 PORT SLATE BROWN SLATE BROWN SLATE BROWN SLATE BROWN ORANGE / ORANGE / ORANGE / ORANGE / ORANGE / ORANGE / ORANGE / ORANGE / BAND (LOW/HI) *SEE NOTES 13 AND 15 VIOLET VIOLET VIOLET VIOLET VIOLET VIOLET VIOLET VIOLET NOTE: ALPHA STARTS AT 0 (NORTH) OR FIRST AZIMUTH AFTER 0 NOTE: BETA IS FIRST AZIMUTH AFTER ALPHA IN CLOCK-WISE DIRECTION SLATE / SLATE / SLATE / SLATE / SLATE / SLATE / SLATE / SLATE / NOTE: GAMMA IS FIRST AZIMUTH AFTER BETA IN CLOCK-WISE DIRECTION BEAM (LEFT/RIGHT) *SEE NOTE 14 BELOW YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW NOTE: DELTA IS FIRST AZIMUTH AFTER GAMMA IN CLOCK-WISE DIRECTION NOTE: AZIMUTH IS IDENTIFIED BY THE PANEL, NOT THE ELEMENTS INSIDE C1-1 C1-2 C2-1 C2-2 C3-1 C3-2 C4-1 C4-2 GAMMA, C, Z, #3 +45 -45 +45 -45 +45 -45 +45 -45 SECTOR GREEN GREEN GREEN GREEN GREEN GREEN GREEN GREEN C ANTENNA WHITE WHITE ORANGE ORANGE BROWN BROWN VIOLET VIOLET PORT SLATE BROWN SLATE BROWN SLATE BROWN SLATE BROWN ORANGE / ORANGE / ORANGE / ORANGE / ORANGE / ORANGE / ORANGE / ORANGE / BAND (LOW/HI) *SEE NOTES 13 AND 15 VIOLET VIOLET VIOLET VIOLET VIOLET VIOLET VIOLET VIOLET CABLE MARKING TAGS SLATE / SLATE / SLATE / SLATE / SLATE / SLATE / SLATE / SLATE / BEAM (LEFT/RIGHT) *SEE NOTE 14 BELOWADDITIONAL YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW IDENTIFIED WITHA IDENTIFICATION CABLES METAL TAG OF STAINLESS STEEL OR BRASS D1-1 D1-2 D2-1 D2-2 D3-1 D3-2 D4-1 D4-2 AND STAMPED WITH THE SECTOR, ANTENNA POSITION, AND CABLE DELTA, D, #4 NUMBER. THE ID MARKING LOCATIONS SHOULD BE AS PER "CABLE +45 -45 +45 -45 +45 -45 +45 -45 MARKING LOCATIONS TABLE". THE TAG SHOULD BE ATTACHED WITH YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW CORROSIVE PROOF WIRE OR WAX STRING AROUND THE CABLE. THE SECTOR TAG SHOULD BE LABLED AS SHOWN BELOW IN FIGURE 2. ANTENNA WHITE WHITE ORANGE ORANGE BROWN BROWN VIOLET VIOLET PORT SLATE BROWN SLATE BROWN SLATE BROWN SLATE BROWN ORANGE / ORANGE / ORANGE / ORANGE / ORANGE / ORANGE / ORANGE / ORANGE / FIGURE 2: TAG DETAIL EXAMPLE BAND (LOW/HI) *SEE NOTES 13 AND 15 VIOLET VIOLET VIOLET VIOLET VIOLET VIOLET VIOLET VIOLET • SLATE / SLATE / SLATE / SLATE / SLATE / SLATE / SLATE / SLATE / BEAM (LEFT/RIGHT) *SEE NOTE 14 BELOW YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW Al-1 B NOTE 1*: ALL COLOR CODE TAPE SHALL BE 3M-35 AND SHALL BE INSTALLED USING A MINIMUM OF (3) WRAPS OF TAPE. CABLE MARKING LOCATIONS TABLE NOTE 2*: ALL COLOR BANDS INSTALLED AT THE TOWER TOP SHALL BE A MINIMUM OF 3" WIDE AND SHALL HAVE A MINIMUM OF 34" OF SPACING BETWEEN EACH COLOR. NOTE 3*: ALL COLOR BANDS INSTALLED AT OR NEAR THE GROUND MAY BE ONLY M" WIDE. EACH TOP-JUMPER SHALL BE COLOR CODED WITH (1) SET OF 3" WIDE BANDS. TAPE TAG LOCATIONS NOTE 4*: EACH MAIN COAX SHALL BE COLOR CODED WITH (1) SET OF 3" BANDS NEAR THE TOP-JUMPER CONNECTION AND WITH '4" COLOR BANDS JUST PRIOR TO EACH TOP JUMPER SHALL BE COLOR CODED ENTERING THE BTS OR TRANSMITTER BUILDING. X WITH (1) SET OF 3" WIDE BANDS. NOTE 5*: ALL BOTTOM JUMPERS SHALL BE COLOR CODED WITH (1) SET OF 34" BANDS ON EACH END OF THE BOTTOM JUMPER. NOTE 6*: ALL COLOR CODES SHALL BE INSTALLED SO AS TO ALIGN NEATLY WITH ONE ANOTHER FROM SIDE-TO-SIDE. NOTE 7*: EACH COLOR BAND SHALL HAVE A MINIMUM OF (3) WRAPS AND SHALL BE NEATLY TRIMMED AND SMOOTHED OUT SO AS TO AVOID UNRAVELING. EACH MAIN COAX SHALL BE COLOR CODED WITH NOTE 8*: X-POLE ANTENNAS SHOULD USE "XX-1" FOR THE "+45" PORT, "XX-2" FOR THE "-45" PORT. (1) SET OF 3" WIDE BANDS NEAR THE NOTE 9*: COLORBAND #4 REFERS TO THE FREQUENCY BAND: ORANGE=850, VIOLET=1900. USED ON JUMPERS ONLY. X TOP-JUMPER CONNECTION AND WITH (1) SET OF NOTE 10*: RF FEEDLINE SHALL BE IDENTIFIED WITH A METAL TAG (STAINLESS OR BRASS ) AND STAMPED WITH THE SECTOR, ANTENNA POSITION, AND CABLE NUMBER. 3/4" WIDE COLOR BANDS JAST PRIOR TO NOTE 11*: ANTENNAS MUST BE IDENTIFIED, USING THE SECTOR LETTER AND ANTENNA NUMBER, WITH A BLACK MARKER PRIOR TO INSTALLATION. ENTERING THE BTS OR TRANSMITTER BUILDING. NOTE 12*: ONLY "SECTOR-SPLIT" ANTENNA COAX SHALL CONTAIN A 5TH COLORBAND TO INDICATE "LEFT" OR "RIGHT" BEAM. NOTE 13*: "SECTOR-SPLIT" ANTENNA COAX SHALL USE BLACK TAPE AS A PLACEHOLDER ON MAINLINE FOR COLORBAND #4 (FREQ BAND) NOTE 14*: "SECTOR-SPLIT" ANTENNAS SLATE FOR THE LEFT BEAM, AND YELLOW FOR THE RIGHT BEAM X MARKING TAGS SHALL BE ATTACHED AT CABLE NOTE 15*: "LOW" BAND REFERS TO 70OMHZ OR 850MHZ, "HI" BAND REFERS TO 190OMHZ OR 210OMHZ ENTRY PORT ON THE INTERIOR OF THE SHELTER ALL BOTTOM JUMPERS SHALL BE COLOR CODED X WITH (1) SET OF 3/4 " WIDE BANDS ON EACH A END OF BOTTOM JUMPER. .,� Apex Engineers, Inc. OSHKOSH HOUSING RELO AT&T MOBILITY ■'1 A a STe Structural & Civil Engineers Lombard, East 22n i Street, Suite B SITE NO. 1551 AT&T / Network Solutions Lombard, Illinois 60148 SITERRA NO. 155185-A COAX FIBER COLOR CODING 1351 E. Irving Park Rd Ph. (630) 627 1800 530 NORTH MAIN STREET ` S A 01/07/19 ISSUED FOR REVIEW YA EW SP Itasca, IL 60143 Fax. (630) 627-1165 OSHKOSH, WI 54901 NO. DATE REVISIONS BY CHK APPT DRAWING NUMBER REV APEX JOB No. AT02-204 SCALE: AS SHOWN DESIGNED BY: XX I DRAWN BY: XX W16037-09 A 6 5 4 3 2 11 z 17 SIZE MIDWEST FIBER—OPTIC JUMPER COLOR CODE STANDARD (Version 2.8 — Updated 5/28/2014) WISIL STANDARD FIBER—OPTIC DEPLOYMENT PLANS (Version 2.8 — Updated 5/28/2014) SECTOR TECHNOLOGY BAND RADIO NAME COLOR CODE INOTES NOTE: ** DENOTES SPECIAL DEPLOYMENT WHERE RRH IS TECHNOLOGY SPLIT WITH UMTS AND LTE LTE 700 LTE-700—Al RED ORANGE BROWN VIOLET NOTE: RRH'S DIPICTED IN PARENTHESES AND ITALICS INDICATE ERICSSON "A2" MODULES LTE 2100 LTE-2100—A2 RED ORANGE WHITE VIOLET FIBER TRUNK #1 LTE 2100 LTE-2100—A3 RED ORANGE WHITE BROWN "A2" MODULE, SEE NOTE 1 BELOW RRH NAME SECTOR TECHNOLOGY BAND FIBER TRAY FIBER TRAY SQUID/TRUNK UMTS 850 UMTS-850—A4 RED SLATE VIOLET VIOLET ID PORT PAIR D LTE 850 LTE-850—A4S RED ORANGE VIOLET YELLOW "TECHNOLOGY—SPLIT" UMTS 1900 UMTS-1900—A5 RED SLATE ORANGE VIOLET LTE-700—Al A LTE 700 A 1 1 LTE 1900 LTE-1900—A5S RED ORANGE ORANGE YELLOW "TECHNOLOGY—SPLIT" LTE-700—B1 B LTE 700 A 2 2 LTE 1900 LTE-1900—A6 RED ORANGE ORANGE SLATE "A2" MODULE, SEE NOTE 1&2 BELOW LTE-700—Cl C LTE 700 A 3 3 LTE 700D E LTE-700DE—A7 RED ORANGE YELLOW VIOLET LTE-2100—A2 LTE-2100-A3 A I LTE 2100 A 4 4 LTE WCS LTE—WCS—AS RED ORANGE SLATE VIOLET LTE-2100—B2 LTE-2100-B3 B LTE 2100 A 5 5 LTE 850 LTE-850—A9 RED ORANGE VIOLET VIOLET LTE-2100—C2 LTE-2100-C3 C LTE 2100 A 6 6 LTE 1900 LTE-1900—A10 RED ORANGE ORANGE VIOLET LTE-1900—A10 (LTE-1900-All) LTE 1900 LTE—1900—A11 RED ORANGE ORANGE BROWN "A2" MODULE, SEE NOTE 1 BELOW **LTE-1900—A5s (LTE-1900-A6) A LTE 1900 A 7 7 LTE 700 LTE-700—B1 BLUE ORANGE BROWN VIOLET LTE-1900—B10 (LTE-1900-B11) LTE 2100 LTE-2100—B2 BLUE ORANGE WHITE VIOLET **LTE-1900—B5s (LTE-1900-B6) B LTE 1900 A 8 8 LTE 2100 LTE-2100—B3 BLUE ORANGE WHITE BROWN "A2" MODULE, SEE NOTE 1 BELOW LTE-1900—C10 (LTE-1900-C11) UMTS 850 UMTS-850—B4 BLUE SLATE VIOLET VIOLET **LTE-1900—05s (LTE-1900-C6) C LTE 1900 A 9 9 LTE 850 LTE-850—B4S BLUE ORANGE VIOLET YELLOW "TECHNOLOGY—SPLIT" LTE-850—A9 LTE-850—A4s A LTE 850 A 10 10 UMTS 1900 UMTS-1900-65 BLUE SLATE ORANGE VIOLET LTE-850-69 LTE-850-64s B LTE 850 A 11 11 LTE 1900 LTE-1900—B5S BLUE ORANGE ORANGE YELLOW "TECHNOLOGY—SPLIT" LTE-850—C9 LTE-850—C4s C LTE 850 A 12 12 LTE 1900 LTE-1900—B6 BLUE ORANGE ORANGE SLATE "A2" MODULE, SEE NOTE 1&2 BELOW SPARE B 7 13 LTE 700D E LTE-700DE—B7 BLUE ORANGE YELLOW VIOLET SPARE B 8 14 LTE WCS LTE—WCS—B8 BLUE ORANGE SLATE VIOLET SPARE I I B 9 15 LTE 850 LTE-850—B9 BLUE ORANGE VIOLET VIOLET SPARE B 10 16 C LTE 1900 LTE-1900—B10 BLUE ORANGE ORANGE VIOLET SPARE B 11 17 LTE 1900 LTE-1900—B11 BLUE ORANGE ORANGE BROWN "A2" MODULE, SEE NOTE 1 BELOW SPARE B 12 18 LTE 700 LTE-700—Cl GREEN ORANGE BROWN VIOLET LTE 2100 LTE-2100—C2 GREEN ORANGE WHITE VIOLET LTE 2100 LTE-2100—C3 GREEN ORANGE WHITE BROWN "A2" MODULE, SEE NOTE 1 BELOW UMTS 850 UMTS-850—C4 GREEN SLATE VIOLET VIOLET FIBER TRUNK 2 LTE 850 LTE-850—C4S GREEN ORANGE VIOLET YELLOW "TECHNOLOGY—SPLIT" UMTS 1900 UMTS-1900—05 GREEN SLATE ORANGE VIOLET RRH NAME SECTOR TECHNOLOGY BAND FIBER TRAY FIBER TRAY SQUID/TRUNK LTE 1900 LTE—1900—05S GREEN ORANGE ORANGE YELLOW "TECHNOLOGY—SPLIT" ID PORT PAIR LTE 1900 LTE-1900—C6 GREEN ORANGE ORANGE SLATE "A2" MODULE, SEE NOTE 1&2 BELOW LTE 700D E LTE-700DE—C7 GREEN ORANGE YELLOW VIOLET UMTS-850—A4 A UMTS 850 C 1 1 LTE WCS LTE—WCS—C8 GREEN ORANGE SLATE VIOLET UMTS-850-64 B UMTS 850 C 2 2 LTE 850 LTE-850—C9 GREEN UMTS-1900 C 3 3 ORANGE VIOLET VIOLET UMTS— LTE 1900 LTE-1900—C10 GREEN ORANGE ORANGE VIOLET 00—A C UMTS 5 A UMTS 1 190900 C 4 4 LTE 11900 1 LTE-1900—Cl 1 GREEN I ORANGE ORANGE BROWN I "A2" MODULE, SEE NOTE 1 BELOW UMTS-1900-65 B UMTS 1900 C 5 5 UMTS-1900—05 C UMTS 1900 C 6 6 NOTE 1: A SECONDARY JUMPER TO A2 MODULES IS REQUIRED WHEN A CARRIER BANDWIDTH EXCEEDS 10x10MHZ. A2 COLOR CODE IS REQUIRED. UMTS-1900—A6 A UMTS 1900 C 7 7 NOTE 2: WHEN DEPLOYING 2 LTE CARRIERS WITHIN THE SAME BAND, F1 IS IDENTIFIED BY BROWN, F2 IS IDENTIFIED BY SLATE. UMTS-1900-66 B UMTS 1900 C 8 8 UMTS-1900—C6 C UMTS 1900 C 9 9 B LTE-700—DE—A7 A LTE 700DE C 10 10 LTE-700—DE—B7 B LTE 700DE C 11 11 LTE-700—DE—C7 C LTE 700DE C 12 12 LTE—WCS—A8 A LTE WCS B 1 13 ALPHA RED LTE—WCS—B8 B LTE WCS B 2 14 BETA BLUE NOTE: "RED", "BLUE", AND "GREEN" ARE NOT USED ON ANY OTHER COLOR BAND AND LTE—WCS—C8 C LTE WCS B 3 15 GAMMA GREEN ALWAYS DE—NOTE THE 1st COLOR BAND ISPARE I I B 1 4 16 UMTS SLATE SPARE I I B 1 5 17 LTE ORANGE SPARE I I I B 1 g 1 18 FREQBAND 700 BROWN 850 VIOLET 1900 ORANGE 2100 WHITE WCS YELLOW 700DE SLATE MASTER VIOLET SPLIT/SLAVE YELLOW >10MHZ A2 MODULE F1 BROWN >10MHZ A2 MODULE F2 SLATE A Apex Engineers, Inc. OSHKOSH HOUSING RELO AT&T MOBILITY ■_ S�� Structural & Civil Engineers Network Solutions Lombard, East 22n Street, Suite B SITE NO. AT&T Lombard, Illinois 60148 SITERRA NO. 155185-A FIBER—OPTIC JUMPER COLOR CODING 1351 E. Irving Park Rd Ph. (630) 627 1800 530 NORTH MAIN STREET ` S A 01/07/19 ISSUED FOR REVIEW YA EW SP Itasca, IL 60143 Fax. (630) 627-1165 OSHKOSH, WI 54901 NO. DATE REVISIONS BY CHK APPT DRAWING NUMBER REV APEX JOB No. AT02-204 SCALE: AS SHOWN DESIGNED BY: XX DRAWN BY: XX WI6037-10 A 6 5 4 3 2 11 x 17 SIZE GENERAL NOTES (USE WHERE APPLICABLE) GENERAL NOTES GROUNDING NOTES 1. FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL APPLY: 1. COAX CABLE SHALL BE GROUNDED AT ANTENNA LEVEL WITHIN 5' OF ANTENNA, COAX WILL ADDITIONALLY BE GROUNDED AT THE CONTRACTOR - GENERAL CONTRACTOR (CONSTRUCTION) BASE OF THE TOWER 18" BEFORE THE CABLE REACHES A HORIZONTAL PLANE. IF EQUIPMENT CABINET IS MORE THAN 15' OWNER - AT&T FROM THE TOWER AN ADDITIONAL GROUND KIT WILL BE ADDED 24" BEFORE CABLE ENTERS CABINET. OEM - ORIGINAL EQUIPMENT MANUFACTURE 2. PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING CONTRACTOR SHALL VISIT THE CELL SITE TO 2. ALL COAX GROUND KITS WILL BE ANDREW "COMPACT SURE GROUND" OR APPROVED EQUAL. FAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN BE ACCOMPLISHED 3. VERIFY THE GROUNDING CONTINUITY BETWEEN THE TOWER BASE AND THE NEW AT&T CABINET GROUND BAR. CONTRACTOR D AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUND SHALL BE BROUGHT TO SHALL ENSURE THAT ALL METALLIC OBJECTS WITHIN 6' FROM CABINET HAVE GROUNDING CONTINUITY. THE CONTRACTOR SHALL THE ATTENTION OF OWNER. CORRECT ANY DEFECTS BY ADDING GROUNDING CONDUCTOR TO ENSURE CONTINUITY. 3. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE 4. CONTRACTOR SHALL PERFORM A GROUND IMPEDANCE TEST PRIOR TO CONSTRUCTION TO ENSURE SITE IS LOWER THAN 5-OHM. CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND IF SITE HAS A RESISTANCE HIGHER THAN 5 OHM REPORT TO AT&T FOR FURTHER DIRECTION. COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. 5. GROUNDING CONDUCTORS SHALL BE COPPER ONLY. EITHER SOLID OR STRANDED CONDUCTORS ARE PERMITTED. ALL EXTERNAL ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY BURIED CONDUCTORS MUST BE BARE. EQUIPMENT GROUND LEADS IN CABLE TRAYS MUST BE GREEN INSULATED. SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 6. CONTRACTOR TO PROVIDE GROUND WIRES, BARS AND CONNECTIONS AS SHOWN ON GROUNDING RISER DIAGRAM. 4. DRAWINGS PROVIDED HERE ARE NOT TO SCALE AND ARE INTENDED TO SHOW OUTLINE ONLY. 7. ROUTE GROUNDING CONDUCTORS ALONG THE SHORTEST AND STRAIGHTEST PATH POSSIBLE, EXCEPT AS OTHERWISE INDICATED. 5. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, RADIUS BENDS OF GROUNDING LEADS TO BE A MINIMUM OF 12". #6 WIRE MAY BE BENT WITH 6" RADIUS BEND WHERE FIELD APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE CONDITIONS PROHIBIT WIDER SWEEPS. DRAWINGS. 8. GROUNDING CONNECTIONS SHALL BE EXOTHERMIC TYPE ("CADWELD") TO ANTENNA MASTS, FENCE POSTS, AND GROUND RODS, 6. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH REMAINING GROUNDING CONNECTIONS SHALL BE COMPRESSION/ MECHANICAL FITTINGS. MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 7. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE OWNER. 8. CONTRACTOR SHALL DETERMINE ACTUAL ROUTING OF CONDUIT, POWER AND T1 CABLES, GROUNDING C CABLES AS SHOWN ON THE POWER, GROUNDING AND TELCO PLAN DRAWING. 9. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND ELECTRICAL NOTES STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. 1. ALL ELECTRICAL WORK SHALL CONFIRM TO THE 2014 NATIONAL ELECTRIC CODE. 10. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL 2. ALL ELECTRICAL ITEMS SHALL BE U.L. APPROVED OR LISTED. CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 3. POWER WIRES AND CABLES SHALL BE COPPER WITH TYPE XHHW, THWN, OR THHN INSULATION. SOLID CONDUCTORS FOR #10 AWG AND SMALLER, STRANDED FOR LARGER THAN #10 AWG. MINIMUM SIZE #12 AWG. 11. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. 4. POWER WIRES OUTSIDE CABINET AND CABLES SHALL BE INSTALLED IN CODE COMPLIANT RIGID CONDUIT OR FLEXIBLE LIQUID 12. ALL WORK SHALL BE IN COMPLIANCE WITH CURRENT VERSION OF AT&T CONSTRUCTION SPECIFICATIONS INCLUDING TIGHT CONDUIT AS INDICATED ON DRAWING. UPDATES. IF CONTRACTOR DOES NOT HAVE A COPY OF SPECS, NOTIFY AT&T IMEDIATELY. 5. CONTRACTOR TO OBTAIN ALL PERMITS, PAY PERMIT FEES, AND BE RESPONSIBLE FOR SCHEDULING INSPECTIONS. 6. CONTRACTOR TO OBTAIN LOCAL POWER AND TELEPHONE COMPANY APPROVAL AND COORDINATE WITH UTILITY COMPANIES SERVICE ENTRANCE REQUIREMENTS. B COAX NOTES 1. MINIMUM SEPARATION BETWEEN ANTENNAS IS 36" IF CONTRACTOR CAN NOT MAINTAIN MINIMUM DISTANCE CONTACT ENGINEER FOR SOLUTION / ALTERNATE DESIGN. 2. COAX CABLE LENGTH SHOWN IS APPROXIMATE. CONTRACTOR IS REQUIRED TO MAKE ACTUAL FIELD MEASUREMENT PRIOR TO PURCHASE AND BE RESPONSIBLE FOR SAME. 3. COAX CABLE SHALL BE RAISED / SUPPORTED WITH HOISTING GRIP AT APPROPRIATE POINTS PER MANUFACTURER REQUIREMENTS. 4. CONTRACTOR WILL PROVIDE COAX CABLE, RF CONNECTORS AND RF GROUNDING KITS. 5. CONTRACTOR SHALL SUPPORT COAX CABLE PER MANUFACTURER REQUIREMENTS. SUPPORT SHALL BE STAINLESS STEEL SNAP IN OR NON-COMPRESSING BUTTERFLY CLAMP. NO NYLON OR PLASTIC "ZIP-TIES" WILL BE ALLOWED. COAX MAY BE UNSUPPORTED INSIDE MONOPOLE INSTALLATIONS. 6. NO COAX SHALL BE OUTSIDE THE POLE MORE THAN 20'-0" (UNLESS OTHERWISE DIRECTED). TO GET FROM AN EXISTING PORTHOLE TO ANTENNA HEIGHT IF DISTANCE IS GREATER THAN 20'-0" A NEW 6"X9" PORTHOLE SHALL BE INSTALLED. PORTHOLE SHALL BE INSTALLED PER TOWER MANUFACTURER REQUIREMENTS. NO HOLES WILL BE CUT WITH A TORCH. ALL HOLES WILL BE CUT WITH DIAMOND WHEEL. NO NEW PORTHOLES SHALL BE INSTALLED UNLESS PRIOR WRITTEN APPROVAL IS GIVEN BY "AT&T". A ■'1 .A, Apex Engineers, Inc. OSHKOSH HOUSING RELO AT&T MOBILITY ST Structural & Civil Engineers Network Solutions Lombard, East 22n Street, Suite B SITE NO. AT&T Lombard, Illinois 60148 SITERRA NO. 155185-A GENERAL NOTES 1351 E. Irving Park Rd Ph. (630) 627 1800 530 NORTH MAIN STREET ` S A 01/07/19 ISSUED FOR REVIEW YA EW SP Itasca, IL 60143 Fax. (630) 627-1165 OSHKOSH, WI 54901 NO. DATE REVISIONS BY CHK APPT DRAWING NUMBER IREVI APEX JOB No. AT02-204 SCALE: AS SHOWN DESIGNED BY: XX DRAWN BY: XX WI6037-11 A 6 5 4 3 2 11 x 17 SIZE