Loading...
HomeMy WebLinkAbout0102691 BOSHKOSH ON THE WATER .lob.Address 1481 WELLINGTON CT Designer CITY OF OSHKOSH BUILDING PERMIT - APPLICATION AND RECORD Owner RUSCH HOMES LLC Contractor RUSCH HOMES LLC Category 110 - New Single Family No 0102691 Create Date 08/25/2003 Plan E1-080-0603R Type I(~ Building (~ Sign (~ Canopy (~ Fence (~ Raze Zoning R-1 Class of Const: 8 Size IRR Unfinished/Basement 1386 Sq. Ft. Rooms 5 Height 16 Ft. ~J Projection Finished/Living 2044 Sq. Ft. Bedrooms 3 Stories 2 Canopies Garage 802 Sq. Ft. Baths 3 Signs Foundation O Poured Concrete (~ Floating Slab (~ Pier (~ Other (~ Concrete Block (~ Post (~ Treated Wood Occupancy Permit Required Flood Plain No Height Permit Not Required Park Dedication Required # Dwelling Units 1 # Structures 1 Use/Nature NSFR/2 story home with a 3 car attached garage, 14'xl 4' rear patio. The driveway will be a maximum of 24' at the lot line. of Work HVAC Contractor CONDON TOTAL COMFORT Plumbing Contractor HANSON QUALITY PLUMBING Electric Contractor CUMINGS ELECTRIC Fees: Valuation $120,000.00 Plan Approval $75.00 Permit Fee Paid $440.00 Park Dedication $100.00 Issued By: Date 07/08/2003 Final/O.P. 00/00/0000 Permit Voided In the performance of this work I agree to perform all work pursuant to rules governing the described construction. Signature Date Agent/Owner Address P O BOX 423 Omro WI 54963 - 0000 Telephone Number 685-0241 OSHKOSH ON THE WATER Name RUSCH HOMES LLC GRADE STAKE FORM Address 1481 WELLINGTON CT Lot 238 Block Subdivision 5th Add to Westleigh Farms Zone Street Number Lot Dimensions Building Grade Elevation Stakes Set At Site 06/26/2003 Set By D.W.G. BK- 590, P-6 Grade Stake Number 6969 Create Date 06/25/2003 Ward Sidewalk Existing Department of Public Works I, the undersigned, owner or agent of the above described property agree to have the grade established before excavation has commenced. OSHKOSH ON THE WATER .lob Address 1481 WELLINGTON CT Name RUSCH HOMES LLC Address P O BOX 423 Subdivision 5th Add to Westleigh Farms Building Permit Number 0102691 Number of Dwelling Units Fee Required PARKLAND DEDICATION FEE COLLECTION RECORD Date 07/08/2003 OMRO WI 54963 Lot 238 1 Number of Structures $100.00 Fee Paid Owner's Signature Inspector's Signature Date Date Wisconsin Department of Industry, WISCONSIN UNIFORM Application No. Labor and Human Relations Safety and Buildings Division BUILDING PERMIT 0102691 P.O. Box 2509 APPLICATION Parcel No. Madison, WI 53701-2509 Wisconsin Statues 101.63, 101.73 [] Constr [] HVAC [] Elec [] Plbg [] Erosion [] Other: Owner's Name Mailing Address Telephone No. RUSCH HOMES LLC P O BOX 423 OMRO WI 54963 - 0000 685-0241 Contractor: L~J Con~J Elec~J HVAC ~J Plbg Lic/Cert # Mailing Address Telephone No. RUSCH HOMES LLC 879882 P O BOX 423 Omro WI 54963 - 0 685-0241 Contractor: ~J Con ~J Elec~J HVAC~J Plbg Lic/Cert # Mailing Address Telephone No. CUMINGS ELECTRIC 170792 PO BOX749 1414 COUNTY RD JJ NEENAH WI 54957 - 749 231-5946 Contractor: ~J Con ~J Elec~J HVAC [] Plbg Lic/Cert # Mailing Address Telephone No. CONDON TOTAL COMFORT 3202 11 BLACKBURN ST RIPON W 54971 - 184 (920) 748-5050 Contractor: ~J Con [] Elec [] HVAC [] Plbg bio/Cart # Mailing Address Telephone No. HANSON QUALITY PLUMBING 550 N BLUEMOUND RD APPLETON WI 54914 - 0 730-0205 I Lot Area Sq. ft. 1/4, 1/4, Section , T N, R E(or)W Building Address Subdivision Name Lot No. Block No. 1481 WELLINGTON CT 5th Add to Westleigh Farms 238 Zoning District(s) lZoning Permit No. Front Rear Left Right J __Setbacks ft ......... _f_t_: ft ft , .,.,~= ~=u~E, --~ ~r~-,, ~ .............................. L~J New [] Repair [] Single Family Entrance Panel L~J Forced Air Furnace Fuel Nat. L.P. Oil Elec. Solid Sola [] Alteration [] Raze [] Two Family Size: 200 amp [] Radiant Baseboard or Panel Gas , [] Addition [] Garage Service: [] Heat Pump Space Htg [] [] [] [] [] [] [] Move [] Other (print): [] Overhead [] Boiler Water Htg [] [] [] [] [] [] [] Other: [] Underground [] Central Air Conditioning * ~J Dwelling unit will have 3 kilowatt or ] 8~l~,lS~ ~Y~E ~ f~OND~ION [] Other = more installed electric space heating equip. [] Site Constructed · Concrete - Infiltration control option is: [] Full sealing Unfinished [] Manufactured · Masonry Sewer of joints. [] Blower door test. [] Exterior Basement 1386 Sq. ft. S 8~IES · Treated Wood [] Municipal air infiltration barrier. Living Area 2044 Sq. ft. [] 1-Story · Other [] Septic [] 2-Story Permit No. Envelope 33823 BTU/HR Garage 802 Sq. ft. [] Other [] Seasonal Infiltration 20918 BTU/HR [] Permanent [] Municipal Utility [] Plus Basement [] Other [] Private On-Site Well $200,000.00 The applicant agrees to comply with all applicable codes, statues and ordinances and with the conditions of this permit, understands that the issuance of the permit creates no legal liability, express or implied, on the Department or municipality; and certifies that all the above information is accurate. APPLICANT'S SIGNATURE DATE SIGNED This permit is issued pursuant to the following conditions. Failure to comply may result in suspension or APPROVAL CONDITIONS revocation of this permit or other penalty see standard conditions of approval [] Town [] Village [] City [] County ~J State of: Municipality Number of Dwelling Location: ~II~BIB~ION City Of Oshkosh 7 0 - 2 6 6 ~IS UN!EORIVl ~ERMI~ ~ERIVlI~ iSSUED B~ ~SS=E= SE~ Ne ~ Construction Plan Review $75.00 _ HVAC Name Nicole Krahn Inspection Electrical Wis. Permit Seal $30.00 Plumbing Date 6/25/O3 Other [] Erosion Total $105.00 · 292206 Cert. No. 248101 SBD-5823 (R. 07/92) CITY OF OSHKOSH Project Address I~'~CO [ Permit # Please read the following information and sign at the bottom to acknowledge that you have read and agree to comply with these conditions. 1. All habitable rooms must be provided with 8% light and 3.5% ventilation. Bedrooms located on the secOnd ~;;'~'_Qr ~!ow ground level must be provided with egress windows in addition to the light and ventilation requirements. Basement windows are also r~quired to trove window well areas in accordance wi~ ~HR ~,~, ...... 2. Garage spaCes shall be separated from the dwelling unit in accordance with ILHR 21.08. The door and frame assembly between the dwelling unit and an attached garage shall be labeled by an i~dependent testin~ agenc¥'as having a minimum fire-resistive rating of 20 minUtes. All drywallj0ints'a26 required to be taped/sealed Unless the joints are fitted so that the gap is no more than a dimes thickness (1/20-inch) ~d backed by solid wood or drywall with the joints staggered. 3. ~11 prior to the insulation inspection. This includes holes in the top and bottom plates, gaps around heating ducts, and holes in the returu air spaces. 4. Smoke detect6is a~e i~e~lUired on every floor and within 6' of all b~drgonts.' The smgke detectors are reqUired to be hardwired and interconnected. ' Hydromassage tubs are required to have an access panel to motor. The access panel must be accessible without removing the finish of the house. ' All overframing must be designed by the tress manufacture~, according to standards sel by the trUss'plate institute, or structural calculations must be provided prior to the rough building inspection. 7. TrUss plans must be submitted and approved prior to framing the roof. 8. Truss plans including the tress layout must be provided on site at the rough building inspection. In addition to the truss plans, microlam calculations must be provided on site at the rough building inspection for all microlams with point loads on them. 9. Calculations must be provided for all cantilevered floors with point loads. Floor tresses and TJI's must be designed for the cantilevered areas. 10. 11. 12. 13. 14. 15. 16. The property owner and applicant is responsible for compliance with ILl-IR 21.125 (Erosion Control). When installing access drives, a minimum of 2"~3" required in addition to.a migin3u_m_~[,~6'2~d~epth, 30'-50' length, and 14'-20' width, Erosion control measures must be ~ntai~d ~u.~fik~e I~wa is es!~lish~¥-:.} All storm sewer inlets must be protected with approved erosion control devices. Tr_ac _king (i.e. sediment) must be removed from the street at the end 0~.~c,h~ ~w.~gr¢,,~_d3y. Repair any siltation or erosion damage to adjoining surfaces and drainageways resulting from land development or disturbing activities. The building placard must be posted on site at all times. Once the rough framing is up the placard must be posted on the patio door or on a kitchen window. If th_e placard is not present at any inspection, stop work oiders will be posted. Additional placards can be obtained through our department if the cards are misplaced. All mechanicals must be roughed in prior to requesting the rough building inspection. If on the inspection the mechanicals are g~[ roughed in, the inspection will fail and a $100 re-inspection fee will be charged. Attached is a copy of the final inspection checklist. At the final inspection all items on this list must be completed to avoid the $100 re-inspection fee per inspection. When requesting final inspections please note that a minimum of 2 days notice is needed from the time the inspection is ready. Furniture is only allowed to be placed in the center 6ftfi~ garage fl0o~and a minimum of~ 3' pathway must be provided aro.~und.the..w_~!S,9.f~ the garage. At the final inspection no furniture or personal belongings are allowed in the house. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in place due to the electric~ inspector needing to look at the power serving the appliances. A 6' stepladder must be on s~te~g~_~C~..~.~gpection to provide access to the attic. The building placard must remain on the patio door or on a kitchen window until occupancy is approved. Occupancy is not allowed prior to the placard having all of the final inspection approved stickers on the backside..If 0~_cupancy occurs prior to the inspections being approved daily citations will be issued with no furthej~ potic~ ~eing given. 17. All site grading must be done in acc0rdang.~.~i~ approved drainage plan on file in the public works office, 3rd floor.