HomeMy WebLinkAbout0104893-Building
104893
CITY OF OSHKOSH No
OSHKOSHBUILDING PERMIT - APPLICATION AND RECORD
ON THE WATER
CLASSIC HOMES BY KUBA
Job Address2440 SHORE PRESERVE DROwnerCreate Date10/07/2003
DesignerContractorCLASSIC HOMES OF APPLETON INC
Category110 - New Single FamilyPlanE1-132-1003R
TypeBuildingSignCanopyFenceRaze
R-1
ZoningClass of Const:8SizeIRR
Sq. Ft.Projection
Unfinished/Basement1158Rooms5Height33Ft.
Finished/Living
2277Sq. Ft.Bedrooms4Stories2Canopies0
Garage692Sq. Ft.Baths3Signs0
Poured ConcreteFloating SlabPierOther
Foundation
Concrete BlockPostTreated Wood
Occupancy PermitRequiredFlood PlainNoHeight PermitNot Required
Park DedicationRequired# Dwelling Units1# Structures1
NSFR/ 2 story home with a 3 car attached garage, NO DECK OR PATIO. (Driveway is maximum of 24' at the lotline)
Use/Nature
of Work
HVAC ContractorBLACK-HAAK HEATINGPlumbing ContractorRAUSCH PLUMBING
Electric ContractorKRUEGER ELECTRIC INC.
Fees: Valuation$161,512.00Plan Approval$75.00Permit Fee Paid$566.00Park Dedication$200.00
10/21/200300/00/0000
Issued By:DateFinal/O.P.
Permit Voided
In the performance of this work I agree to perform all work pursuant to rules governing the described construction.
While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work
described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement
holder(s) and to secure any necessary approvals before starting such activity.
SignatureDate
Agent/Owner
2525 S ONEIDA STAPPLETONWI549150000730-0985
Address-Telephone Number
To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of
Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone
Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may
continue if the inspection is not performed within two business days from the time the project is ready.
Wisconsin Department of Industry,
WISCONSIN UNIFORM Application No.
Labor and Human Relations
BUILDING PERMIT
0104893
Safety and Buildings Division
P.O. Box 2509
Parcel No.
APPLICATION
Madison, WI 53701-2509
Wisconsin Statues 101.63, 101.73
PERMIT REQUESTED üü ConstrHVAC
ElecPlbgOther:
üü Erosion
Owner's NameMailing AddressTelephone No.
CLASSIC HOMES BY KUBAOshkoshWI54901-0000
Contractor:
üü ConElecHVACPlbg
Mailing AddressTelephone No.
Lic/Cert #
CLASSIC HOMES OF APPLETON INC2525 S ONEIDA STWI0
2346 APPLETON54915-730-0985
Contractor:Mailing AddressTelephone No.
Con üü ElecHVACPlbg
Lic/Cert #
KRUEGER ELECTRIC INC.WI0
267602 1409 VANDENBROEK RDLITTLE CHUTE54140-(920) 788-7118
Contractor:Mailing AddressTelephone No.
ConElec üü HVAC
Plbg
Lic/Cert #
11193 APPLETONWI54914(920) 757-9990
BLACK-HAAK HEATINGPO BOX 3070-3070
Contractor:Mailing AddressTelephone No.
Con
ElecHVAC üü Plbg
Lic/Cert #
RAUSCH PLUMBINGAPPLETON54911-0
832 E MAYFIELD DRWI730-2831 (C) 213-7030
Lot Area
PROJECT LOCATION
1/4,1/4,Section,TN,RE(or)W
Sq. ft.
Building AddressSubdivision NameLot No.Block No.
2440 SHORE PRESERVE DR5
Northshore Preserve Plat
Zoning District(s)Zoning Permit No.FrontRearLeftRight
Setbacksft.ft.ft.ft.
1. PROJECT3. OCCUPANCY6. ELECTRICAL9. HVAC EQUIPMENT12. ENERGY SOURCE
üü New üü Forced Air Furnace
Nat.L.P.OilElec.SolidSolar
üü Single Family
Entrance Panel
Repair
Fuel
Gas
*
Two FamilyRadiant Baseboard or Panel
amp
Alteration
200
Size:
Raze
Garage
Space Htg
Service:
Heat Pump
Addition
Move
Other (print):Overhead
üü
Water Htg
Boiler
üü Underground
Other: üü Central Air Conditioning
*Dwelling unit will have 3 kilowatt or
4. CONST. TYPE7. FOUNDATION
Other
more installed electric space heating equip.
Concrete
2. AREA INVOLVED
üü Site Constructed
10. PLUMBING
Infiltration control option is:Full sealing
Masonry
Manufactured
Unfinished
Sewer
of joints.Blower door test.Exterior
Treated Wood
Basement1158Sq. ft.
air infiltration barrier.
üü Municipal
5. STORIES
Other
13. HEAT LOSS (Calculated)
1-Story
Septic
Living Area2277Sq. ft.
8. USE
34894
EnvelopeBTU/HR
Permit No.
üü 2-Story
692
GarageSq. ft.
Seasonal
14174
InfiltrationBTU/HR
Other
11. WATER
üü Permanent
14. EST. BUILDING COST
üü Municipal Utility
Other
$203,412.00
Plus BasementPrivate On-Site Well
The applicant agrees to comply with all applicable codes, statues and ordinances and with the conditions of this permit, understands that the issuance of
the permit creates no legal liability, express or implied, on the Department or municipality; and certifies that all the above information is accurate.
APPLICANT'S SIGNATURE
DATE SIGNED
This permit is issued pursuant to the following conditions. Failure to comply may result in suspension or
APPROVAL CONDITIONS
revocation of this permit or other penalty
see standard conditions of approval
State of:
TownVillage üü CityCounty
Municipality Number of Dwelling Location:
ISSUING
7 0 - 2 6 6
City Of Oshkosh
JURISDICTION
PERMIT(S)WIS. UNIFORM PERMIT
FEES:PERMIT ISSUED BY:
ISSUEDSEAL NO.
üü Construction
Plan Review$75.00
Nicole Krahn
Name
HVAC
Inspection
Electrical
Wis. Permit Seal$30.00
10/7/03
Plumbing
Date
üü Erosion
Other
248101
Cert. No.
292232
$105.00
Total
SBD-5823 (R. 07/92)
PARKLAND DEDICATION FEE COLLECTION RECORD
OSHKOSH
ON THE WATER
Job Address 2440 SHORE PRESERVE DRDate10/21/2003
NameCLASSIC HOMES BY KUBA
AddressOshkoshWI54901
SubdivisionNorthshore Preserve PlatLot5
Building Permit Number0104893
Number of Dwelling Units1Number of Structures1
Fee Required$200.00Fee Paid
Owner's SignatureDate
Inspector's SignatureDate
GRADE STAKE FORM
OSHKOSH
Grade Stake Number7049
ON THE WATER
NameCLASSIC HOMES BY KUBAAddress2440 SHORE PRESERVE DRCreate Date10/07/2003
Block
Lot5Ward
SubdivisionNorthshore Preserve PlatZone
Sidewalk Existing
Street NumberLot Dimensions
Building Grade Elevation Stakes Set At Site10/07/2003Set By D.W.G. BK - 593 , P - 60
Department of Public Works
I, the undersigned, owner or agent of the above described property agree to have the grade established before excavation
has commenced.
CITY OF OSHKOSH
STANDARD CONDITIONS OF APPROVAL
Project Address tS jermit #
Please read the following information and sign at the bottom to acknowledge that you have read
and agree to comply with these conditions.
1. All habitable rooms must be provided with 8% light and 3.5% ventilation. Bedrooms
located on the second floor or below ground level must be provided with egress windows
in addition to the light and ventilation requirements. Basement windows are also
required to have window well areas in accordance with ILHR 21.03.
2. Garage spaces shall be separated from the dwelling unit in accordance with ILHR 21.08.
The door and frame assembly between the dwelling unit and an attached garage shall be
labeled by an independent testing agency as having a minimum fire- resistive rating of 20
minutes. All drywall joints are required to be taped /sealed unless the joints are fitted so
that the gap is no more than a dimes thickness ( 1/20 -inch) and backed by solid wood or
drywall with the joints staggered.
3. All penetrations in exterior walls must be sealed prior to the insulation inspection. This
includes holes in the top and bottom plates, gaps around heating ducts, and holes in the
return air spaces.
4. Smoke detectors are required on every floor and within 6' of all bedrooms. The smoke
detectors are required to be hardwired and interconnected.
5. Hydromassage tubs are required to have an access panel to motor. The access panel must
be accessible without removing the finish of the house.
6. All overframing must be designed by the truss manufacturer, according to standards set
by the truss plate institute, or structural calculations must be provided prior to the rough
building inspection.
7. Truss plans must be submitted and approved prior to framing the roof.
8. Truss plans including the truss layout must be provided on site at the rough building
inspection. In addition to the truss plans, microlam calculations must be provided on site
at the rough building inspection for all microlams with point loads on them.
9. Calculations must be provided for all cantilevered floors with point loads. Floor trusses
and TJI's must be designed for the cantilevered areas.
10. The property owner and applicant is responsible for compliance with ILHR 21.125
(Erosion Control). When installing access drives, a minimum of 2 " -3" diameter stone is
required in addition to a minimum of 6" depth, 30' -50' length, and 14' -20' width. Erosion
control measures must be maintained until the lawn is established.
11. All storm sewer inlets must be protected with approved erosion control devices. Tracking
(i.e. sediment) must be removed from the street at the end of each workday. Repair any
siltation or erosion damage to adjoining surfaces and drainageways resulting from land
development or disturbing activities.
12. The building placard must be posted on site at all times. Once the rough framing is up
the placard must be posted on the patio door or on a kitchen window. If the placard is not
present at any inspection, stop work orders will be posted. Additional placards can be
obtained through our department if the cards are misplaced.
13. All mechanicals must be roughed in prior to requesting the rough building inspection. If
on the inspection the mechanicals are not roughed in, the inspection will fail and a $100
re- inspection fee will be charged.
14. Attached is a copy of the final inspection checklist. At the final inspection all items on
this list must be completed to avoid the $100 re- inspection fee per inspection.
15. When requesting final inspections please note that a minimum of 2 days notice is needed
from the time the inspection is ready. Furniture is only allowed to be placed in the center
of the garage floor and a minimum of a 3' pathway must be provided around the walls of
the garage. At the final inspection no furniture or personal belongings are allowed in the
house. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in
place due to the electrical inspector needing to look at the power serving the appliances.
A 6' stepladder must be on site at the final inspection to provide access to the attic.
16. The building placard must remain on the patio door or on a kitchen window until
occupancy is approved. Occupancy is not allowed prior to the placard having all of the
final inspection approved stickers on the backside. If occupancy occurs prior to the
inspections being approved daily citations will be issued with no further notice being
given.
17. All site grading must be done in accordance with the approved drainage plan on file in the
public works office, 3rd floor.
S icjnafure o /.AEt Cicant: