HomeMy WebLinkAbout0104695-Plumbing (water heater)OSHKOSH
ON THE WATER
.lob Address 51 MILL ST
Contractor SHAWN ZAGRODNIK
CITY OF OSHKOSH
PLUMBING PERMIT - APPLICATION AND RECORD
Owner CARLA/CHRISTIN SIMPSON
Category 410 - Residential-Interior
No 104695
Create Date 10/09/2003
Plan
Bathtub 0 Shower 0 Ejector/Grind 0 DipWell 0 F Prep Sink 0 Gar Drain 0
Whirlpool 0 Floor Drain 0 Water Soffner 0 Drink Ftn 0 Serv Sink 0 Soda Disp 0
Lavatory 0 Lndry Tray 0 LocalWaste 0 Wait. St. 0 Shamp Sink 0 Coffee Maker 0
Toilet 0 Lndry Stndp 0 ClothesWshr 0 Ice Chest 0 FIr/Wst Sink 0 Int Grease Trap 0
Res. Sink 0 Disposal 0 Bidet 0 Exam Sink 0 Catch Basin 0 Ext Grease Trap 0
Bar Sink 0 Dishwasher 0 Beer Tap 0 SculrySink 0 Wash Ftn 0 RPZValve 0
Water Heater 1 Sump Pump 0 Dent. Oper. 0 Hand Sink 0 Urinal 0 EyeWash Statn 0
Site Drain 0 Classrm Sink 0 Lab Sink 0 Plaster Sink 0 Standp Rec 0
Roof Drain 0 Breakrm Sink 0 Sterilizer 0 Surgeons Sink 0 Ice Maker 0
Use/Nature
of Work
Replace water heater and
install building control valve and some replacement of water distribution piping.
Sanitary Sewer
Storm Sewer
Water Service
Size Material Type #
Conn. Type
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Valuation $1,100.00 Plan Approval $0.00 Permit Fees $20.00 ~J Permit Voided
Issued By
Date
10/09/2003
In the performance of this work, I agree to perform all work pursuant to rules governing the described construction.
While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work
described in this permit application within an easement, the City strongly urges the permit applicant to contact the
easement holder(s) and to secure any necessary approvals before starting such activity.
Signature Date
Agent/Owner
Address 5011 RIVERMORE DR OMRO WI 54963 - 0000 Telephone Number
920-685-5263
To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of
Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone
Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may
continue if the inspection is not performed within two business days from the time the project is ready.
WA'T'ER CALCULATION WORKSHEET FOR / ' /7 �‹ rr
NAME OF PROJECT
INFORMATION REQUIRED TO CALCULATE WATER SERVICE SIZE
1. Demand of building in building in gallons per minute. WSFU's / . " C = (GPM) L ®• 1
2. Difference in elevation from main or extemal pressure tank to building control valve. (feet) .
3. Size of water meter (when meter is required) 5/8" _, 3/4" 1" _ , 1 -1/2" _ , 2" _ , larger size Y
4. Developed length from main or extemal pressure tank to building control valve. (feet) Vs
5. Low pressure at main in street or extemal pressure tank. (psi) S7 •
CALCULATE WATER SERVICE PRESSURE LOSS p
6. Low pressure at main in street or extemal pressure tank. (value of # 5 above) ` J 7 ! s
7. Determine pressure loss due to friction in / i nch diameter ,,gip
water service. � Subtract value of "7" 12
(Water service piping material is J I r. 1
e 9 c ,_ i a subtotal
8. Determine pressure Toss due to elevation, 11 ,, � y
(multiply the value of # 2 above by .434) 3 , Subtract value of "8" 3 r y/
9. Available pressure after the bldg. control valve. (enter in "B" below) subtotal
CALCULATE THE PRESSURE AVAILABLE FOR UNIFORM LOSS (VALUE OF "A ")
B. Available pressure after the bldg. control valve. (from "9" above) Value of "B" / 72 '
C. Pressure loss of water meter (when meter is required) Subtract value of "C" / ' '
subtotal y / A y
D. Pressure at controlling fixture. M 2 �- , Subtract value of "D" v� d P I
(Controllin g fixture is �J� p t ie t�. ` 1 o
subtotal .l O
E. Difference in elevation between the building control valve
and the controlling fixture in feet /6 X .434 psi/ft. Subtract value of "E" 6), 9
subtotal /3,1
F. Pressure loss due to water treatment devices, instantaneous
water heaters and backfiow preventers which serve the
controlling fixture. Subtract value of "F"
(Pressure loss due to
subtotal / 3e
G. Developed length from building control valve to controlling
fixture in feet Se) X 1.5 s : Divide by value of "G" 75 -
I subtotal ./
(Water distribution piping material is /, I )
Multiply by 100
A. Pressure available for uniform loss =
SBD -6479 (R11/98) ( j