Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
0102181-HVAC
OSHKOSH ON THE WATER .lob Address 600 S MAIN ST #201 Contractor MCM AIR INC Fuel ~J Gas ~ System ~J New ~J Forced Air 1 ~J Electric I CITY OF OSHKOSH HVAC PERMIT - APPLICATION AND RECORD Oil Radiant Hot Water Owner JAMES F/PAULA F CONDOR Category 510 - Ind. & Comm-Heating & Ventilating L~ Electric Replace L~ Steam L~ suppl. Solar A/C Con. Burner Chimney Type I~ ChimneyA Heat Loss I~ As Approved BTU Rate I~ As Per Plan Chimney B ~ Existing ~ Variable Direct Vent Not Applicable Not Applicable Other Value Value No Create Date Plan L~ Solid 102181 06/13/2003 Other J Vent J Use/Nature of Work Combine units 201 and 203 into one office suite/Install Renewaire Energy Recovery Ventilator. Fees: Valuation Issued By: $1,500.00 Plan Approval $0.00 Permit Fee Paid Permit Voided J $27.50 Date 06/13/2003 In the performance of this work, I agree to perform all work pursuant to rules governing the described construction. Signature Date Agent/Owner Address 6122 COUNTY ROAD M WINNECONNE WI 54986 -9780 Telephone Number (920) 582-4402 City of Oshkosh ~Division of Impection Services . ,~ ,~ /',~1!~"~ P.O. Box 1130 ' ' OshkOsh, WI 54903-1130 . . Phone (920) 23~-S0S0 . HVAC PERMff A~PL. LqA?IO~i · ~o~1~ applicafio~ ~n not ~ ' -~'~ "/0~ ~d f~(s) ~ b~ ~o~t ~ Ci~ Hall, ~m 20~ ~ ~ ~ ~~~ PO Box 112% Os~osh ~ 54903-112S; Co~c~g W~k M~out ~s) ~11 n~l ~t f~, w~ch ~v~ is ~t~. OR if vou want t~l~ ~o~ t~ou~ vou~ ~ount ~ JOB ~D~SS CONTRACTOR MCM AIR, INC. '6122 CHECK [] ALL APPLICABLE COUNTY RD M, WINNECONNE, WI 54986 '. 5.82r4402 . FAX 582-0.136 USE CATEGORY [ZlSingle Family [ZlDuplex I-IMulti-Fnmfly [2Rental ]~ommemial I-IIndustrial FUEL [ZlGas CIElectric ~Solid [2lOil ~]Solar TYPE CIForced Air r'lRadiant I-ISteam FI,adC SYSTEM ]~]~l~w ~IR~I~.~ .. OOth~- '~' ' Vent~\ [ZIElectfi~ [ZIHotW~t~ I'lSuppl. I-]Con. Burner IS CHIMNEY BEING LINED l-lNo OYes - LINER SIZE Note: All chinmeys shall be sized per the BTU's being vented. & MANUFA~ CHIMNEY TYPE HEAT LOSS BTU RATE OChinme¥ A OAs Approved OAs Per Plan OChimney B ElExisting OVariable ElDirect Vent r'lNot Applicable ClOther Value EIOther DESCRIPTION OF ALL WORK BEING DONE {Ixl6TA-Lt_ · ~&~VOAl ~ VALUE (Including labor and all rn~te~als including Hght fixtures) $ ~ 500 O0 ELECTRICAL CONTRACTOR ~%) ' bO ~'~--5 ~U ~ C'Y ~_-- ~ C. ~ ~v (L) [3 For applicable projects, an Electric Installation Verification form, si~ned by the Electrical 'Contractor, must bc attached. If not attached or not applicable, a separat~ Electrical P~mit is required. 9/02 F:::XtSTIN® PUF;8.NAC, D~--~_ ~ ,,; ,,,,, ..... :,,,~ ,,. Ol=:PI CF:::-IP2 COPY t~.hl, OPPICE-IE RECEPTION EXISTIN® SUPPLY AIR IPlPPUSER,~ BALANCE TO CFI'd SHOI.,',tN (TYPICAL) t0'-0" hllN: I OPPICE-tPl OPPICE-C 260 OPPICF::::-. B2 OFFICE-BI OPPtCE-A H,V,A,C,. FLOOF;;- PLAN SCALE: D/16" = 1'-O" OUTSII:PE AIR FILTER DLOY",IER COhIPARThlENTS AIR TOAIREXCHANGER SCHEDULE DESIG. ERV-I MANUFACTURER RENEP,IAI~E MODEL ~ EVI50 EXHAUST OD~ IO5 SUPPLY CFM IO5 EFFICIENCY VOLTAGE I~O-1¢ PLA I.I ~EIGHT 59 LBS. NOTE: PROVIDE VOLUME IPAI'.dPERS TO ALLOIAf F'OR BALANCING OF SYSTEM. NOTE: INTERLOCK UNIT tAIITH ROOl'fl LIGHT CIRCUIT TO OPERATE CONTINUOUS EPURING OCCUPANCY'. EXHAUST F:tLTER ENERGY Tt~ANSPER RA = ROOl'-fl AIR TO BE EXHAUSTED - ROUTE t=ROI"I EXISTING, RA DUCT CA = OUTSIDE AIR INTAKE - ROUTE PROI',,1 CUTE)COPS FA = F::RE'.BH AIR TO INSIDE - ROUTE TO EXIBTIN® SA IDUCT DA = EXHAUST AIR TO OUT$tlPE - t~OUTE TO OUTDOORS Ei~V UNIT DETAIL (F:RONT NOT TO SCALE P-..OO hd NAb'IR O.S.AI P-. t EQ ALP--. fvtOVEh'IENT FLOO (so. A tEA PT,) ACTUAL. EStGN ACTUAl_ PEStGN OPPICE-A 15 -70 512 t5 ;; :: 525 OFFICE-BI -7,5 .50 152 -7.5 ": *;: 150 OFFiC, D-B2 -1.5 45 200 7.5 t82 41 OPFICE-C OPPICE-DI -/.5 54 150 OFFICE-D2 -7.5 52 144 COPIER -7.5 14 85 -7.5 OFPICE-E 18 80 -7.5 RECEPTION 50 14 ©4 50 ;:;, ©5 .... GENERAL NOTES: I-DUCT DIMENSIONS SHOk"4N ON DEAF, lINGs-- AP--,E INSIDE DIMENSIONS. 2..-DUCTS ARE TO BE INSTALLED ACCORDING TO STATE CODE AND SMAONA GUIDELINES. ,.6-ALL DUCTS SHALL BE CONSTRUCTED AND INSULATED IN ACCORDANCE F',IlTH SECTION 605 AND SECTION 604 THE INTERNATIONAL MECHANICAL CODE AS HOE>IF:lED BY CHAPTER COl',dht. 64. 4-ALL DUCTS LOCATED OUTSIDE OP THE CONDITIONED SPACE SHALL BE INc~.)LATED. .DUCTS OUTSIDE OF THE THERMAL ENVELOPE SHALL BE INSULATED TO R--7.5. DUCTS YIITHIN THE THERMAL ENVELOPE SHALL BE INSULATED TO 5-F:RESH AIt~. INTAKE(S) TO BE A MINIMUM IO'-O" F:ROM ANY VENT OR F'LUE OUTLET. d:;,-PRESH AIR INTAKE(S) TO BE A MINIMUM 12" ABOVE ANTICIPATED SNOF',t DEPTH. 'q-ELECTRICAL Y',IIRING OF' tl5 VOLTS OP--.. ABOVE tS TO BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. 24 VOLT CONTROL tAIIRING IS TO BD THE RESPONSIBILITY OF THE: HVAC CONTRACTOR. 8-EXHAUST AIR IS TO BE VENTED TO THE EXTEP-,IOt~ OF THE BUILDING. q-VENTILATION IS TO RUN CONTINUOUS DURING BUILDING OCCUPANCY. IO-HVAC CONTRACTOR SHALL BE RESPONSIBLE FOR TESTING, CALIBRATING, AND ADJUSTING ALL HVAC CONTROL SYSTEMS. I I-HVAC CONTRACTOR SHALL BE RESPONSIBLE FOR TESTING AND BALANCING OF THIS SYSTEM. HVAC CONTRACTOR SHALL DOCUMENT tN k',IRITING THE AMOUNT OF O.S.AtR BEING PROVIDED AND DISTRIBUTED TO THE E~ILDiNG OCCUPANTS, AND ANY OTHER SPECIALTY VENTILATION. A COF'Y OF' THIS DOCUMENT SHALL BE RETAINED AT THE -_!OB SITE AND SHALL BE IviAPE AVAILABLE TO DEPARTMENT O~= COMMERCE PERSONEL UPON REQUEST. 12-HVAC CONTRACTOR SHALL BE RESPONSIBLE F'OR PROVIDING THE BUILDING Oi,'INER OR OPERATOR AN OPERATING AND MAINTENANCE MANUAL. THE h"I/~,.NUAL SHALL INCLUDE BASIC DATA RELATING TO THE OPERATION AND IvlAINTENANCE OF ALL HVAC SYSTEMS AND EQUIPMENT. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY IDENTIFIED. P4HERE APPICABL. E, HVAC CONTROL INFORMATION SUCH AS DIAGRAMS, SCHEMATICS, CONTP--..OL SEQUENCE DESCRIPTIONS, MAINTENANCE, AND CALIBRATION INPORMATION SHALL BE INCLUDED. INDEX OF SHEETS SHEET 5HE:_ET SHEET FLOOR PLAN-SC, HEDULES-E;;'ETA I L % m ::z: o_.m_z Z Z DP-.AtdN BY: hi.C,. APPROVED , DATE 6-10-O5 JOB NO. 9-785 SHEET tOPi