Loading...
HomeMy WebLinkAbout0096473-Electric � + � � CITY OF OSHKOSH No 96473 OSHKOSH ELECTRIC PERMIT -APPLICATION AND RECORD ON THE WATER Job Address 2251 WESTOWNE AVE Owner HOLIDAY INN EXPRESS&SUITES Create Date 08/07/2002 Contractor CF POWER LLC Category 643-Commercial-Addition/Remodels Plan Service New � Change 0 Temp Type � Overhead Q Underground � Volts Circuits 0 Fixtures 3 Amps 0 Switches 0 Receptacles 3 Appliances h Use/Nature of OMM/Motel/Wiring for conversion of existing double unit(DQ2013)into a new meeting room with a capacity of 20 people as per plan. Work -Remove bathroom,and install cabinets with wet bar sink within this room. Fees: Valuation $500.00 Plan Approval $0.00 Permit Fee Paid $20.00 Issued By: �1M Date 08/07l2002 � Permit Voided I In the performance of this work I agree to perform all work pursuant to rules governing the described construction. Signature Date AgenUOwner Address 615 E DIVISION ST FOND DU LAC WI 54935 -0 Telephone Number 920-923-3954 � Division of Inspection Services � 215 Church Avenue P.O. Box 1130 �SdJ �� Oshkosh, WI 54903-1130 Fax (920) 236-5084 ON�HEWATER phone (920) 236-5046 � ELECTRICAL PERMIT APPLICATION All information after bold categories must be provided. Incomplete applications will not be processed. DATB Q-a.-� JOB ADDRESS �0�� LvESTnwu� �/� �M o�t��_� owx$R�y .xh.rV CONTRACTOR C. F. ��F�_ CIRCLE ALL APPLICABLI3 US$ CAT$GORY SINGLE FAMILY DUPLEX MULTI-FAMILY RENTAL OMMERCI INDUSTRIAL S$RVICB NEW CHANGE TEMPORARY �LOT APPLICABL TYPB OVERHEAD UNDERGROUND NOT APPLICABLE NO. OF FIXTURES�_ SWITCHES RECEPTACLES�� CIRCUITS AMPS VOLTS / PHAST CH$CK ALL APPLICABL$ R�1NGE WATER HEATER GARBAGE DISPOSAL DRYER DISHWASHER FAN OR BLOWER FURNACE A/C ELECTRIC SIGN MOTORS GAS PUMPS OTHER DBSCRIPTION OF ALL WORK B$ING DONE �m��c� n� 12r�-�r✓►. ��,,v,�•tf t3�t-TH,2cx� f1n� I2��rr�tT�ivv car�nti� • Submit payment with application. Failure to pay within 30 days will result in fees being doubled or $100 .00 plus the normal permit fee, which ever is greater. VALIIE (Including labor and all materials including light fixturas) $ �(�.QC� MASTSR SLBCTRICIAN �j��� C�ry��'JrV1� � Electric Permit Work Card Jmb Address 2251 WESTOWNE AVE Permit Number 139364 Create Date 12/7/2009 Owner OSHKOSH PRO PARTNERS Contractor KAUFMAN ELECTRIC SHOP INC Service I� New � Change� Temp � N/A Type � Overhead � Underground � N/A ' Volts Circuits Luminaires Amps Switches Receptacles Value $5,000.00 i ----- -- -------.._ Use/Nature ,Holiday Inn Express*Corrections for work conducted by A Cut Above the Rest Remodeling".This remodeling was in the , of Work bathrooms in(69)the hotel rooms without permits or qualified local contractors. Inspections: Date 03/02/2010 Type Final Inspector Kevin Benner cancelled I will inspect when the other work is completed so I can inspect all of the installations at one time Date/Time requested:02/09/2010 01:17 PM Notice Type: Ready Date/Time: 02/09/2010 01:17 PM Access: Requested by: KAUFMAN ELECTRIC SHOP INC Phone Number: 920-948-2995 John � Reinspect Fee � Fee Wavied ❑ Reinspect Fee Paid --------------------- -- - ---------------------------------------- --- ---- ------------ - - - - - - - ------------ Electric Permit Work Card Job Addsess 2251 WESTOWNE AVE Permit Number 139364 Create Date 12/7/2009 � _ __ _ ___ _ . Owner OSHKOSH PRO PARTNERS Contractor KAUFMAN ELECTRIC SHOP INC Service � New � Change� Temp � N/A ! Type � Overhead � Underground � N/A i Volts Circuits Luminaires --- Value $5,000.00 : Amps Switches Receptacles -- of Wo kure I�,bathr oms in(69)the hotel rtooms wi ho t perm tstotlquaAfiedtlocalv ont acors.Remodeling''.This remodeling was in the I i . '-- - - _ -_ _ _ __ � Inspections: Date 01/05/2010 Type Re Final Inspector Kevin Benner approved w/cond. --__ _ ------ - - ---- --- --- 3rd Floor South Wing ll il Date/Time requested:01/04/2010 03:17 PM Notice Type: Ready Date/Time: 01/05/2010 00:00 AM , Access: Requested by: KAUFMAN ELECTRIC SHOP INC Phone Number: 920-948-2995 John � Reinspect Fee� Fee Wavied ❑ Reinspect Fee Paid -------------------- - - - - - -------------------- -- -- ---- ------------------------ - - ' Date 01/12/2010 Type Re Final Inspector Kevin Benner no time — -- - ---- - _ - - _ __ Field Request Date/Time requested:01/05/2010 00:00 AM Notice Type: Ready Date/Time: 01/07/2010 00:00 AM Access: Requested by: KAUFMAN ELECTRIC SHOP INC Phone Number: 920-948-2995 John � Reinspect Fee� Fee Wavied ❑ Reinspect Fee Paid Date Type Re Final Inspector Kevin Benner -- ------ -- _ _---- - _ Will be done Tuesday 1/12/10 or Wednesday 1/13/10 iJohn estimated that approximately 4 units will be remaining on the 3rd floor after today. Rooms 1003 8�1005 will also be remaining until a Idecision can be made how to address these with the assistance ofA Cut Above the Rest Const.Co.to do the drywall work. Date/Time requested:01/11/2010 11:59 AM Notice Type: Ready Date/Time: 01/12/2010 00:00 PM Access: Requested by: KAUFMAN ELECTRIC SHOP INC Phone Number: 920-948-2995 John � Reinspect Fee � Fee Wavied ❑ Reinspect Fee Paid --------------------------- -- - -- --- - --------------------------- -- - -- - ------------- --------- -__ - Date Type Final Inspector Kevin Benner _- —_ _ ----------_.._ _ --------- __� - - - _ ----- - _ _ __ ` -- � ----� Date/Time requested:02/02/2010 01:47 PM Notice Type: Ready Date/Time: 02/04/2010 11:00 AM Access: John will be on site with the carpenters Requested by: KAUFMAN ELECTRIC SHOP INC Phone Number: 920-948-2995 John � Reinspect Fee � Fee Wavied ❑ Reinspect Fee Paid -------------------------- ----- --------- -- --- -- ---------- - -- ---------- - - - ___ _ __ _ � Electric Permit Work Card Jub Address 2251 WESTOWNE AVE Permit Number 139364 Create Date 12/7/2009 Owner OSHKOSH PRO PARTNERS Contractor KAUFMAN ELECTRIC SHOP INC -- - _ _-- Service � New � Change� Temp � N/A Type � Overhead � Underground � N/A ' Volts Circuits Luminaires -- - _ __ Value $5,000.00 Amps Switches Receptacles - - -- _- ------ -- - - Use/Nature 'Holiday Inn Express'Corrections for work conducted by A Cut Above the Rest Remodeling".This remodeling was in the of Work bathrooms in(69)the hotel rooms without permits or qualified local contractors. Inspections: Date 12/07/2009 Type Note Inspector Kevin Benner --- - - --__ - ------ __ __ — - ------ _ �fhe buiiling inspector and I noticed semi trailers in the parking lot with building materials inside and outside.Went in and noticed the ��remodeling and the associated violations. informed the installers to stop work immediately and get qualified contractors and permits. Date/Time requested:12/07/2009 12:00 PM Notice Type: Ready Date/Time: 12/07/2009 12:00 PM Access: Requested by: Phone Number: � Reinspect Fee � Fee Wavied ❑ Reinspect Fee Paid - -- ------------------- -- - - ------------------------------------ - - -- - ------------------------ - -- Date 12/22/2009 Type Consultation Inspector Kevin Benner CN __-_ _- - ----- ----- ------ -- --------- — -- -- --- ---- - _ _ _ Reviewed the existing code violations with John and discussed a plan to correct them in all of the rooms.Also present was the building inspector,hotel manager and the maintenance person. : ! __-- - _ ---_--- - _ _ ' Date/Time requested:12/22/2009 10:03 AM Notice Type: Ready Date/Time 12/22/2009 01:45 PM Access: Meet in the lobby Requested by: KAUFMAN ELECTRIC SHOP INC Phone Number: 920-948-2995 John � Reinspect Fee� Fee Wavied ❑ Reinspect Fee Paid ------------------ ---------- -- -- -- ------------------------------------ - - -- - -------------------------- - - -- -------- Date 12/23/2009 Type Final Inspector Kevin Benner approved w/cond. Phrtial Vor'roo n s i f the south9YPg west side The exisitng violations which were discovered was concealpd splices made w�thou9boxes, i oxes with the backs cut off, sum channeled to install NM cable on the surface with notched shallow an boxes m lewof fittin s,etc. ��ese o at o s a e what was recogomzed to this point and are being corrected. ' � Date/Time requested:12/23/2009 07:39 AM Notice Type: Ready DatelTime: 12/23/2009 11:00 AM Access: Ken Miller is the manager Requested by: KAUFMAN ELECTRIC SHOP INC Phone Number: 920-948-2995 John � Reinspect Fee 0 Fee Wavied ❑ Reinspect Fee Paid - - --------------------------- - --------------------------------- - --- - - -- --- --------------------- -- Date 12/29/2009 Type Re Final Inspector Kevin Benner not approved - _ _-- - --- __-- - -_ _ Just started working on the north wing on the west side. ', INot ready ', I__ --- -- Date/Time requested:12/23/2009 00:00 AM Notice Type: Ready Date/Time: 12/29/2009 00:00 AM Access: Ken Miller is the manager Requested by: KAUFMAN ELECTRIC SHOP INC Phone Number: 920-948-2995 John � Reinspect Fee� Fee Wavied ❑ Reinspect Fee Paid _ - - --- ------ _ _ - --- - --- --------- --- -- -_ .. - ----- - ------------ -- - -