Loading...
HomeMy WebLinkAbout0101755-BuildingOSHKOSH ON THE WATER Job Address Designer Category Type ~ B~u_ilding Zoning R-1PD Unfinished/Basement Finished/Living Garage Foundation Occupancy Permit Park Dedication 2374 SHORE PRESERVE DR 110 - New Single Family CITY OF OSHKOSH Required Required No 0101755 BUILDING PERMIT APPLICATION AND RECORD Owner D&J QUALITY CONSTRUCTION Create Date Contractor D & J QUALITY CONSTRUCTION Plan E1-065-0503R Size Irrg Canopies Signs 18 Ft. Class of Const: 8 2389 Sq. Ft. Rooms 6 Height 2389 Sq. Ft. Bedrooms 3 Stories 1 720 Sq. Ft. Baths 3 Poured Concrete (~ Floating Slab ~) Pier {~ Other Concrete Block (~ Post ~) Treated Wood Flood Plain No # Dwelling Units 1 Height Permit Not Required # Structures I 05/15~2003 Use/Nature of Work NSFPJ New single family 1 story with 3 car attached garage and 13' x 25' deck. HVAC Contractor MCM AIR INC Electric Contractor WITZKE ELECTRIC Fees: Valuation $210,375.00 Plan Approval $75.00 Issued By: ~ [] Permit Voided Plumbing Contractor WATTERS PLUMBING Permit Fee Paid $713.00 Park Dedication $100.00 Date 05/27/2003 Final/O.P. 00/00/0000 In the performance of this work,,I a,9,r,.e,~ to perform all,work pursuant to rules governing the described construction. Address 2415 HICKORY LN OSHKOSH WI 54901 - 0000 Telephone Number 232"0538 OSHKOSH ON THE WATER Name D&J QUALITY CONSTRUCTION GRADE STAKE FORM Address 2374 SHORE PRESERVE DR Lot 12 Block Subdivision North Shore Preserve Zone Street Number Lot Dimensions Building Grade Elevation Stakes Set At Site 05/16/2003 Set By Grade Stake Number 6950 Create Date 05115/2003 D.W.G. BK-588, P-41 Ward Sidewalk Existing Department of Public Works I, the undersigned, owner or agent of the above described property agree to have the grade establish.ed befo_,rpe excavation Wisconsin'Department of Industry, WlSCO N SI N U N IFC RM Application NO. L;~bor and Human Relations Safety and Buildings Division BUILDING PERMIT 0101755 P.O. BOX 2509 APPLICATION Parcel No. MadisOn, WI 53701-2509 Wisconsin Statues 101.63, 101.73 ~ B .~Ee Constr [] Elec [] Plbg [] Erosion [] Other: HVAC Owner's Name Mailing Address Telephone No. D&J QUALITY CONSTRUCTION 2415 HICKORY LN Oshkosh WI 54901 - 0000 232-0538 Contractor: ~j Con[~ Elec'E~] HVAC ~ Plbg Lic/Cert# I Mailing Address Telephone No. D & J QUALITY CONSTRUCTION 666726 2415 HICKORY LN OSHKOSH WI 54901 - 0 232-0538 Contractor: ~j Con ]~1 Bec [~ HVACL~ Plbg Lic/Cer[# Mailing Address Telephone No. WlTZKE ELECTRIC M2021 PO BOX 102 155 E PACKER AVE OSHKOSH WI 54903 - 102 920-235-6572 Contractor: b~ Con [_j Elec]~J HVAC [] PIb_c Lic/Cert # Mailing Address Telephone No. MCM AIR INC 4264 6122 COUNTY ROAD M WINNECONNfW154986 - 9780 (920) 582-4402 Contractor:L_j Con [] Elec[~ HVAC[~ Plbg Lic/Cert # Mailing Address Telephone No. W/~TTERS PLUMBING 1303 MIDWAY RD, PO BOX 118 MENASHA WI 54952 - 1129 800-801-8125,7; ~ ~Lo Sq. ft 1/4, 1/4,Section ,T N,R E(or)W Area Building Address Subdivision Name Lot No. Block No. 2374 SHORE PRESERVE DR North Shore Preserve 12 Zoning District(s) Zoning Permit No. Front Rear Left Right Setbacks ft. ft. ft. ft ]_~ New [] Repair [] Single Family Entrance Panel ~j Forced Air Furnace Fuel Nat. L.P. Oil Elec. Solid Sola ;E~ Alteration [] Raze ~ Two Family Size: 200 amp [] Radiant Baseboard or Panel Gas · E~ AdditionL~ Garage Service: E~ Heat Pump Space Htg [] [] [] [] [] ~ [] Move [] Other (print): [] Overhead [] Boiler Water Htg [] [] [] [] [] [] [] Other: ......... ~ ...... .,.,. ~ [] Underground ~ ........ , ............ [] Central Air Conditioning * ~ Dwelling unit will have 3 kilowatt or ~~ [] Site Constructed ~] Concrete ~~~Ot~er more installed electric space heating equip. Infiltration control option is: [] Full sealing Unfinished [] Manufactured ~] Masonry Sewer of joints. [] Blower door test. [] Exterior Basement 2389 Sq. ft. ~ Treated Wood [] Municipal air infiltration barrier. Living Area 2389 Sq. ft. '"[~"'~'~;~$'~~ Other Garage 720 Sq. ft. [] 2-Story ~ [] Septic Permit No. Envelope 43347 BTU/HR [] Other [] Seasonal ~~ Infiltration 35596 BTU/HR [] Plus Basement [] Other [] Private On-Site Well $240,000.00 The applicant agrees to comply with all applicable cod, es, st~.~es and ordinance~nd with the conditions of this permit, understands that the issuance of the permit creates no legal liability, express or imp~lJ~¢8, f~"fhecl~eJ~ent o~nicipality; and certifies that all the above information is acc~urate. ~ ~ Th's~permit is issued pursuant to the following conditions. Failure to comply may result in suspension or APPROVAL CONDITIONS revocation of this permit or other penalty SEE "STANDARD CONDITIONS OF APPROVAL" SHEET ! ~' .~ ~ [] Town [] Village [] City [] County bJ State of: Municipality Number of Dwelling Location: City Of Oshkosh 7 0 - 2 6 6 -¢' Construction Plan Review $75.00 __ HVAC Name JOHN ZARATE Inspection ~_ Electrical Wis. Permit Seal $30.00 [] Plumbing Date 5/21/03 Other [] Erosion Total $105.00 ~----} 292145 Cert. No. 70330 SBD-5823 (R. 07/92) OSHKOSH ON THE WATER Job Address PARKLAND DEDICATION FEE COLLECTION RECORD 2374 SHORE PRESERVE DR D&J QUALITY CONSTRUCTION Date 05/27/2003 Name Address 2415 HICKORY LN Oshkosh WI 54901 Subdivision North Shore Preserve Lot 12 Building Permit Number 0101755 Number of Dwelling Units Number of Structures Fee Required Owner's Signature ~ Inspector's Signature $100.00 Fee Paid Date Date O/HKO/H ON THE WATER City of Oshkosh Division of Inspection Services 215 Church Avenue PO Box 1130 Oshkosh WI 54903-1130 Office 920-236-5050 Fax 920-236-5084 PLAN REVIEW Project Address:2374 SHORE PRESERVE DR Submitted By:D&J QUALITY CONSTRUCTION Plan Number:E1-065-0503R Reviewed By: JZ Phone: 920-236-5119 Date Reviewed: 5/21/2003 Phone Number: 232-0538 [--] Mailed [~] Faxed [5~ Delivered Date: Result of Plan Review: [5~ Conditionally Approved [--] Withheld Pending Approval of Additional Information [---] Not-Approved, Plans Returned for Revisions Conditions Noted on Plan Review 4) 5) Smoke detectors are required in each bedroom. 1) Minimum natural light shall be provided to all habitable rooms. 2) 1 ~ 32" wide door shall be provided to a least 1 full bathroom. 3) Beam calculations shall be provided (prior to pouring the basement floor or framing inspection) for any beams or headers over 6' in length or that have point loads imposed on. Verify post pad sizes upon review of the beam calculation for the basement beam. CITY OF OSHKOSH STANDARD CONDITIONS OF APPROVAL Project Address 2 37 ~ SP~OP.,~ PP-~ ~eRv e- Permit # Please read the following information and sign at the 'bottom to acknowledge that you have read and agree to comply with these 'conditions. All habitable rooms must be provided with 8% light and 3.5% ventilation. Bedrooms located on the second floor or below ground level must be provided with egress windows in addition to the light and ventilation requirements. Basement windows are also required to have window well areas in accordance with ILHR 21.03. Garage spaces shall be separated from the dwelling unit in accordance with ILHR 21.08. The door and frame assembly between the dwelling unit and an attached garage shall be labeled by an independent testing agency as having a minimum fire-resistive rating of 20 minutes. All drywall joints are required to be taped/sealed unless the joints are fitted so that the gap is no more than a dimes thickness (1/20-inch) and baCk6d by S01id WoOd or drywall with the joints staggered. o All penetrations in exterior walls must be sealed prior to the insulation inspection. This includes holes in the top and bottom plates, gaps aroutid heating ducts, and holes in the return air spaces. Smoke detectors are required on every floor and within 6' of all bedrooms. The smoke detectors are required to be hardwired and interconnected. Hydromassage tubs are required to haVe an acCess panel to mOtor. The acceSs panel must be accessible without removing the finish of the house. o All overframing must be designed by the tress manufacturer, according to ~tandards set by the truss plate institute, or structural calculations must be provided prior to the rough building inspection. 7. Truss plans must be submitted and approved prior to framing the roof. o Truss plans including the truss layout must be provided on site at the rough building inspection. In addition to the truss plans, microlam calculations must be provided on site at the rough building inspection for all microlams with point loads on them. Calculations must be provided for all cantilevered floors with point loads. Floor trusses and TJI's must be designed for the cantilevered areas. 10. 11. 12. 13. 14. 15. 16. The property owner and applicant is responsible for compliance with ILHR 21.125 (Erosion Control). When installing access drives, a minimum of 2"-3" diameter stone is required in addition to a minimum of 6" depth, 30'-50' length, and 14'-20' width. Erosion control measures must be maintained until the lawn is established. All storm sewer inlets must be protected with approved erosion control devices. Tracking (i.e. sediment) must be removed from the street at the end of each workday. Repair any siltation or erosion damage to adjoining surfaces and drainageways resulting from land development or disturbing activities. The building placard must be posted on site at all times. Once the rough framing is up the placard must be posted on the patio door or on a kitchen window. If the placard is not present at any inspection, stop work orders will be posted. Additional placards can be obtained through our department if the cards are misplaced. All mechanicals must be roughed in prior to requesting the rough building inspection. If on the inspection the mechanicals are not roughed in, the inspection will fail and a $100 re-inspection fee will be charged. Attached is a copy of the final inspection checklist. At the final inspection all items on this list must be completed to avoid the $100 re-inspection fee per inspection. When requesting final inspections please note that a minimum of 2 days notice is needed from the time the inspection is ready. Furniture is only allowed to be placed in the center of the garage floor and a minimum of a 3' pathway must be provided around the walls of the garage. At the final inspection no furniture or personal belongings are allowed in the house. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in place due to the electrical inspector needing to look at the power serving the appliances. A 6' stepladder must be on site at the final inspection to provide access to the attic. The building placard must remain on the patio' door or on a kitchen window until occupancy is approved. Occupancy is not allowed prior to the placard having all of the final inspection approved stickers on the backside. If occupancy occurs prior to the inspections being approved daily citations will be issued with no further notice being given. 17. All site grading must be done in accordance with the approved drainage plan on file in the public works office, 3rd floor.