HomeMy WebLinkAbout0101755-BuildingOSHKOSH
ON THE WATER
Job Address
Designer
Category
Type ~ B~u_ilding
Zoning R-1PD
Unfinished/Basement
Finished/Living
Garage
Foundation
Occupancy Permit
Park Dedication
2374 SHORE PRESERVE DR
110 - New Single Family
CITY OF OSHKOSH
Required
Required
No 0101755
BUILDING PERMIT APPLICATION AND RECORD
Owner D&J QUALITY CONSTRUCTION Create Date
Contractor D & J QUALITY CONSTRUCTION
Plan E1-065-0503R
Size Irrg
Canopies
Signs
18 Ft.
Class of Const: 8
2389 Sq. Ft. Rooms 6 Height
2389 Sq. Ft. Bedrooms 3 Stories 1
720 Sq. Ft. Baths 3
Poured Concrete (~ Floating Slab ~) Pier {~ Other
Concrete Block (~ Post ~) Treated Wood
Flood Plain No
# Dwelling Units 1
Height Permit Not Required
# Structures I
05/15~2003
Use/Nature
of Work
NSFPJ New single family 1 story with 3 car attached garage and 13' x 25' deck.
HVAC Contractor MCM AIR INC
Electric Contractor WITZKE ELECTRIC
Fees: Valuation $210,375.00 Plan Approval $75.00
Issued By: ~
[] Permit Voided
Plumbing Contractor WATTERS PLUMBING
Permit Fee Paid
$713.00 Park Dedication $100.00
Date 05/27/2003 Final/O.P. 00/00/0000
In the performance of this work,,I a,9,r,.e,~ to perform all,work pursuant to rules governing the described construction.
Address 2415 HICKORY LN OSHKOSH WI 54901 - 0000 Telephone Number
232"0538
OSHKOSH
ON THE WATER
Name D&J QUALITY CONSTRUCTION
GRADE STAKE FORM
Address 2374 SHORE PRESERVE DR
Lot 12 Block
Subdivision North Shore Preserve Zone
Street Number Lot Dimensions
Building Grade Elevation Stakes Set At Site 05/16/2003 Set By
Grade Stake Number 6950
Create Date 05115/2003
D.W.G. BK-588, P-41
Ward
Sidewalk Existing
Department of Public Works
I, the undersigned, owner or agent of the above described property agree to have the grade establish.ed befo_,rpe excavation
Wisconsin'Department of Industry, WlSCO N SI N U N IFC RM Application NO.
L;~bor and Human Relations
Safety and Buildings Division BUILDING PERMIT 0101755
P.O. BOX 2509 APPLICATION Parcel No.
MadisOn, WI 53701-2509
Wisconsin Statues 101.63, 101.73
~ B .~Ee Constr [] Elec [] Plbg [] Erosion [] Other:
HVAC
Owner's Name Mailing Address Telephone No.
D&J QUALITY CONSTRUCTION 2415 HICKORY LN Oshkosh WI 54901 - 0000 232-0538
Contractor: ~j Con[~ Elec'E~] HVAC ~ Plbg Lic/Cert# I Mailing Address Telephone No.
D & J QUALITY CONSTRUCTION 666726 2415 HICKORY LN OSHKOSH WI 54901 - 0 232-0538
Contractor: ~j Con ]~1 Bec [~ HVACL~ Plbg Lic/Cer[# Mailing Address Telephone No.
WlTZKE ELECTRIC M2021 PO BOX 102 155 E PACKER AVE OSHKOSH WI 54903 - 102 920-235-6572
Contractor: b~ Con [_j Elec]~J HVAC [] PIb_c Lic/Cert # Mailing Address Telephone No.
MCM AIR INC 4264 6122 COUNTY ROAD M WINNECONNfW154986 - 9780 (920) 582-4402
Contractor:L_j Con [] Elec[~ HVAC[~ Plbg Lic/Cert # Mailing Address Telephone No.
W/~TTERS PLUMBING 1303 MIDWAY RD, PO BOX 118 MENASHA WI 54952 - 1129 800-801-8125,7;
~ ~Lo Sq. ft 1/4, 1/4,Section ,T N,R E(or)W
Area
Building Address Subdivision Name Lot No. Block No.
2374 SHORE PRESERVE DR North Shore Preserve 12
Zoning District(s) Zoning Permit No. Front Rear Left Right
Setbacks ft. ft. ft. ft
]_~ New [] Repair [] Single Family Entrance Panel ~j Forced Air Furnace Fuel Nat. L.P. Oil Elec. Solid Sola
;E~ Alteration [] Raze ~ Two Family Size: 200 amp [] Radiant Baseboard or Panel Gas ·
E~ AdditionL~ Garage Service: E~ Heat Pump Space Htg [] [] [] [] [] ~
[] Move [] Other (print): [] Overhead [] Boiler Water Htg [] [] [] [] [] []
[] Other: ......... ~ ...... .,.,. ~ [] Underground
~ ........ , ............ [] Central Air Conditioning * ~ Dwelling unit will have 3 kilowatt or
~~ [] Site Constructed ~] Concrete ~~~Ot~er more installed electric space heating equip.
Infiltration control option is: [] Full sealing
Unfinished [] Manufactured ~] Masonry Sewer of joints. [] Blower door test. [] Exterior
Basement 2389 Sq. ft. ~ Treated Wood [] Municipal air infiltration barrier.
Living Area 2389 Sq. ft. '"[~"'~'~;~$'~~ Other
Garage 720 Sq. ft. [] 2-Story ~ [] Septic
Permit No. Envelope 43347 BTU/HR
[] Other [] Seasonal ~~ Infiltration 35596 BTU/HR
[] Plus Basement [] Other [] Private On-Site Well $240,000.00
The applicant agrees to comply with all applicable cod, es, st~.~es and ordinance~nd with the conditions of this permit, understands that the issuance of
the permit creates no legal liability, express or imp~lJ~¢8, f~"fhecl~eJ~ent o~nicipality; and certifies that all the above information is acc~urate. ~
~ Th's~permit is issued pursuant to the following conditions. Failure to comply may result in suspension or
APPROVAL CONDITIONS
revocation of this permit or other penalty
SEE "STANDARD CONDITIONS OF APPROVAL" SHEET
! ~' .~ ~ [] Town [] Village [] City [] County bJ State of: Municipality Number of Dwelling Location:
City Of Oshkosh 7 0 - 2 6 6
-¢' Construction
Plan Review $75.00 __
HVAC Name JOHN ZARATE
Inspection ~_ Electrical
Wis. Permit Seal $30.00 [] Plumbing Date 5/21/03
Other [] Erosion
Total $105.00 ~----} 292145 Cert. No. 70330
SBD-5823 (R. 07/92)
OSHKOSH
ON THE WATER
Job Address
PARKLAND DEDICATION FEE COLLECTION RECORD
2374 SHORE PRESERVE DR
D&J QUALITY CONSTRUCTION
Date 05/27/2003
Name
Address 2415 HICKORY LN
Oshkosh WI 54901
Subdivision North Shore Preserve
Lot 12
Building Permit Number 0101755
Number of Dwelling Units
Number of Structures
Fee Required
Owner's Signature ~
Inspector's Signature
$100.00
Fee Paid
Date
Date
O/HKO/H
ON THE WATER
City of Oshkosh
Division of Inspection Services
215 Church Avenue
PO Box 1130
Oshkosh WI 54903-1130
Office 920-236-5050
Fax 920-236-5084
PLAN REVIEW
Project Address:2374 SHORE PRESERVE DR
Submitted By:D&J QUALITY CONSTRUCTION
Plan Number:E1-065-0503R
Reviewed By: JZ
Phone: 920-236-5119
Date Reviewed: 5/21/2003
Phone Number: 232-0538
[--] Mailed
[~] Faxed
[5~ Delivered Date:
Result of Plan Review:
[5~ Conditionally Approved
[--] Withheld Pending Approval of Additional Information
[---] Not-Approved, Plans Returned for Revisions
Conditions Noted on Plan Review
4)
5) Smoke detectors are required in each bedroom.
1) Minimum natural light shall be provided to all habitable rooms.
2) 1 ~ 32" wide door shall be provided to a least 1 full bathroom.
3) Beam calculations shall be provided (prior to pouring the basement floor or framing
inspection) for any beams or headers over 6' in length or that have point loads imposed on.
Verify post pad sizes upon review of the beam calculation for the basement beam.
CITY OF OSHKOSH
STANDARD CONDITIONS OF APPROVAL
Project Address 2 37 ~ SP~OP.,~ PP-~ ~eRv e- Permit #
Please read the following information and sign at the 'bottom to acknowledge that you have read
and agree to comply with these 'conditions.
All habitable rooms must be provided with 8% light and 3.5% ventilation. Bedrooms
located on the second floor or below ground level must be provided with egress windows
in addition to the light and ventilation requirements. Basement windows are also
required to have window well areas in accordance with ILHR 21.03.
Garage spaces shall be separated from the dwelling unit in accordance with ILHR 21.08.
The door and frame assembly between the dwelling unit and an attached garage shall be
labeled by an independent testing agency as having a minimum fire-resistive rating of 20
minutes. All drywall joints are required to be taped/sealed unless the joints are fitted so
that the gap is no more than a dimes thickness (1/20-inch) and baCk6d by S01id WoOd or
drywall with the joints staggered.
o
All penetrations in exterior walls must be sealed prior to the insulation inspection. This
includes holes in the top and bottom plates, gaps aroutid heating ducts, and holes in the
return air spaces.
Smoke detectors are required on every floor and within 6' of all bedrooms. The smoke
detectors are required to be hardwired and interconnected.
Hydromassage tubs are required to haVe an acCess panel to mOtor. The acceSs panel must
be accessible without removing the finish of the house.
o
All overframing must be designed by the tress manufacturer, according to ~tandards set
by the truss plate institute, or structural calculations must be provided prior to the rough
building inspection.
7. Truss plans must be submitted and approved prior to framing the roof.
o
Truss plans including the truss layout must be provided on site at the rough building
inspection. In addition to the truss plans, microlam calculations must be provided on site
at the rough building inspection for all microlams with point loads on them.
Calculations must be provided for all cantilevered floors with point loads. Floor trusses
and TJI's must be designed for the cantilevered areas.
10.
11.
12.
13.
14.
15.
16.
The property owner and applicant is responsible for compliance with ILHR 21.125
(Erosion Control). When installing access drives, a minimum of 2"-3" diameter stone is
required in addition to a minimum of 6" depth, 30'-50' length, and 14'-20' width. Erosion
control measures must be maintained until the lawn is established.
All storm sewer inlets must be protected with approved erosion control devices. Tracking
(i.e. sediment) must be removed from the street at the end of each workday. Repair any
siltation or erosion damage to adjoining surfaces and drainageways resulting from land
development or disturbing activities.
The building placard must be posted on site at all times. Once the rough framing is up
the placard must be posted on the patio door or on a kitchen window. If the placard is not
present at any inspection, stop work orders will be posted. Additional placards can be
obtained through our department if the cards are misplaced.
All mechanicals must be roughed in prior to requesting the rough building inspection. If
on the inspection the mechanicals are not roughed in, the inspection will fail and a $100
re-inspection fee will be charged.
Attached is a copy of the final inspection checklist. At the final inspection all items on
this list must be completed to avoid the $100 re-inspection fee per inspection.
When requesting final inspections please note that a minimum of 2 days notice is needed
from the time the inspection is ready. Furniture is only allowed to be placed in the center
of the garage floor and a minimum of a 3' pathway must be provided around the walls of
the garage. At the final inspection no furniture or personal belongings are allowed in the
house. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in
place due to the electrical inspector needing to look at the power serving the appliances.
A 6' stepladder must be on site at the final inspection to provide access to the attic.
The building placard must remain on the patio' door or on a kitchen window until
occupancy is approved. Occupancy is not allowed prior to the placard having all of the
final inspection approved stickers on the backside. If occupancy occurs prior to the
inspections being approved daily citations will be issued with no further notice being
given.
17. All site grading must be done in accordance with the approved drainage plan on file in the
public works office, 3rd floor.