Loading...
HomeMy WebLinkAboutHVAC 11/16/1981� � '.� .. � +,t�'� " StStC Of WISCOIISIII \ Department o( Indushy, Labor and Human Relations November 6, 1987 sncerv a sui�mmcs oivisiom File Number E-99202 Mr. Rollin Benson Marshall Nelson & Associates 2110 West Silver Spring Drive Milwaukee� Wisconsin 53Z09 Dear Mr. Benson: Factory/Warehouse Addition Banner Packaging� Inc., Non Sowle� Owner 3550 Moser Street Oshkosh� Winnebago County Plan Number 81-09-0305-B Volume: 405,000 Cubic Feet $54 Inspection Fee Paid Follin F. Benson� Supervising Engineer 201 E. WaSFinglon Avenue P.O. Box ]969 Mudlson, W�rzconzin 53J0] Heating and ventilating plans have been reviewed by the Department of Industry� Labor and Human Relations for compliance with the important code requirements. The plans are stamped "Conditionally Approved," and construction may proceed subject to local regulations, but all items that are required to be changed by this letter must be corrected before commencing that part of the work. You are hereby advised that the owner as defined in Chapter 101.01 (2) (i) of the Wisconsin State Statutes is responsible for all code requirements not specifically cited herein. Code requirements are set forth in Chapters 50 thr� 64 of the Rules of the Department. The building will be inspected during and after construction by a deputy of this Department to insure complete compliance with Wisconsin Codes. The owner may notify the state building inspector listed below if a final inspection is desired before taking possession of the building. Ind 50.15 Evidence of approval. The architect, professional engineer, designer� builder or owner shall keep at the building� one set of plans bearing the stamp of approval. Ind 64.48 The infrared heaters shall be equipped with a type "B" vent whieh extends at least 2 feet above the roof as well as 2 feet higher than a ridge� peak or wall within 10 feet of a vent as specified in Ind 64.45. 3- vJ-�,� DiLHF�5B0-5544 .., � ' Mr. Rollin Benson November 6, 1g81 Page 2 Ind 63.01(2) and SO.Oi(2)(e) The owner is respo�sible for the submittal of illumination plans as required by Section Ind 63•o1(2). The illumination plans shall be signed and sealed by a Wisconsin registered architect� engineer or electrical tlesigner if the building contains more than 50�000 cubic feet 1❑ volume. Four copies of the Illumination Power Budget form (SBD-5315) may be used i� lieu of four sets of plans on smaller projects without electrical layouts. A fixture schetlule must accompany eaeh plan or form. An illumination submittal requires a$35 fee when submittetl separately or a$10 fee when submitted with other plans. A separate illumination submittal requires a properly signed plan approval application form (SB-718). Sincerely, Jerry Albrecht Staff Engineer JA:TH0904 cc: R-3 Covill� phone 715-3�6-3�93, Friday a.m. i'Oshkosh Building Inspector Mr. Ron Sowle Banner Packaging, Inc. 3550 Moser Street Oshkosh� Wisconsin 549az