Loading...
HomeMy WebLinkAboutESL Smoke Detector Compatibility Index , Wide 2-wire compatibility Sensitivity testing built-in CleanMe� maintenance alert system ��� ��:�;�.E3 ity Fire & Life Safety ESL Smoke Detector Com pati bi I ity I ndex ;��: �, . i �� �:, � ��r � : � .�, .,. xra, . . _ a .� �. : _ _ �. imagination at work�,, ! 1; ti ' October 2004 L � INTRODUCTION The ESL Detector Compatibility Index has been compiled in order to provide you with a simple cross reference of the many compatibility listings that ESL or the panel manufacturers have obtained.Underwriters Laboratories,Inc.has confirmed that the ESL,UL-Listed Fire Sensors are electrically compatible with the UL-Listed Control Units as shown in the tables. The Index is organized alphabetically by control unit manufacturer.Each manufacturer's listing specifies a control unit,the applicable loop style(formerly Class A or B wiring►,the control unit compatibility identification,the maximum number of ESL detectors allowable per initiating circuit and the ESL Compatibility Identifier. To use this index: • First,look up the control unit and determine the ESL Compatibility Identifier. • Next,turn to the Identifier Cross Reference List to determine the ESL detectors (and Bases)which are compatible. • We have provided the Identifier Cross Reference List sorted by both Identifier Number and Detector Model Number for your convenience. This listing should provide you with all the information you require for determination of compatibility. It should also be sufficient information to answer any questions raised by the AHJ(Authority Having Jurisdiction►on any projects.Please have the name of the control unit manufacturer and control unit description handy when you call Technical Services at 1-800-648-7424,so we can provide you with the correct information. fire Sensors and Control Units and their compatibility are subject to change without notice. ESL has made every attempt to provide complete,accurate and up-to-date information.We are not responsible for omissions or errors.If you would like ESL to add a new panel to its compatibility listings,please contact ESL Marketing at 1-800-547-2556. Please have the name of the control unit manufacturer and control unit description handy when you call. Note on Four-Wire Detectors: Four-Wire Detector Compatability listings are not required by UL,therefore no Four-Wire Detectors are included in the compatability index.A Four-Wire Detector is considered compatible if the voltage range of the detector equals or exceeds the voltage range of the control panel power supply,and if sufficient current is available to insure the operation of all detectors. Note on Carbon Monoxide Detectors: Carbon Monoxide combatibility listings are not required by UL,therefore no Carbon Monoxide Detectors are included in the compatability index.A Carbon Monoxide Detector is considered compatible if the voltage range of the detector equals or exceeds the voltage range of the control panel power supply,and if sufficient current is available to insure the operation of all detectors. ESL 505 Module CleanMeT"' Interpreter and 2 to 4-Wire Input Converter Module • '��e 505 Module serves as an interface between the ESL '�'1 Series smoke detector and any UL Listed 12/24V DC :�ntrol panel:* • Interprets 521 CleanMeTM'signal for any panel • • AI lows central station to be notified when detector needs � to be cleaned • Converts any current ESL 2-wire smoke detector to 4-wire inputs of any panel • 3 diagnostic LEDs • Ensures 2-wire compatibility with any control panel U� California State Fire Marshal Approved usteo Specifications Operation Voltage 12V-33V DC Standby Current 15mA+/-10% AlarmCurrent 50mA+�-10°� SmokeOetectorTrouble � Luop Trou61e Power/Alarm form A contacts 500mA C�36V DC(resistive) (Blinking Steadyl % 5'" Form C contacts 2 Amps�28V DC or 120V DC(resistive� i L c � ' � L J Number of detectors/module 20 `— - Operating Temperature -20°C to 55°C Humidiry 0-95%non-condensing RFI Immunity 20V/M @ 0-1 ghz Static Immunity 25,000 V Transient Immuniry 2,500 V�1.5J � � ��� �- ��-�%"� Color whitelwhite � ��„ Mounting Mountable to 4°square,double gang boxes ��-� �J �.,�. � i % Material Flame retardant plastic cover IUL-94V-0) , � � Field wiring size 12-24 AWG b ` � Ordering Information Model Description Number 505 Module that interprets the 521's CleanMeT"^signal for any panel and can convert 2-wire 521 Series detectors to 4-wire inputs on these panels CleanMe"is a trademark of GE Security and is protected under the following U.S.Patent No.:5,708,414. *CleanMeT""Compatible control panels that do not require use of the 505 module: ADVENT(GE Security)Panels DMPXR70 DMP XR20 DMP XR200 DMP XR5FUXR5SL Napco Gemini 320012V Burg/Fire Panel Napco Gemini 960012V Burg/fire Panel Silent Knight SK4224 24V FACP , Contents Identifier Cross Reference List(Sorted by IdentifierJ...............................................................................4 Identifier Cross Reference List(Sorted by Model Numberi.....................................................................4 � Ademco.............................................................................................................................................................5 ADTSecurity Sysiems,Inc............................................................................................................................5 ' Advantor...........................................................................................................................................................5 AlisonControl Inc............................................................................................................................................6 AuthCompany..................................................................................................................................................6 Autocal!Corporation,A Division of Thorn Automated Systems..............................................................6 � BurleIndustries...............................................................................................................................................7 ` C&K Systems,Inc..........................................................................................................................................7 ; CerberusPyrotronics......................................................................................................................................7 DetectionSystems,Inc. .................................................................................................................................8 Digita/Monitoring Products,Inc.(DMP/.....................................................................................................8 Digital Security Controls/DSCI.....................................................................................................................9 ' Edwards(Edwards Systems Technolo9Y1...................................................................................................9 Ellenco,lnc.....................................................................................................................................................10 Faraday,Inc....................................................................................................................................................10 ; FederalSignal Corporation..........................................................................................................................11 FireBurglary Instruments............................................................................................................................11 : Firecom,Inc....................................................................................................................................................11 FireControl Instruments...............................................................................................................................11 : Firelite..............................................................................................................................................................11 firstA/ert........................................................................................................................................................12 Gamewell........................................................................................................................................................12 ; GE Securiry(Aritech,Caddx,ESL,ITI,Moose).........................................................................................12 HarringtonSignal..........................................................................................................................................13 Honeywell,Inc...............................................................................................................................................13 ; JohnsonControls,Inc...................................................................................................................................14 Landis&GYR(MCC PowersJ.......................................................................................................................14 Mirtone............................................................................................................................................................14 . NapcoSecurity Systems..............................................................................................................................15 NationalGua�dian.........................................................................................................................................15 Notifier............................................................................................................................................................16 OpTexMorse,Inc...........................................................................................................................................16 Pem-Ali Fire Extinguisher Corporation......................................................................................................16 PotterElectric Signal Company..................................................................................................................16 ProtectowireCompany.................................................................................................................................16 Radionics,Inc. ...............................................................................................................................................17 Safetech,Inc..................................................................................................................................................17 Scantronic(USAJ,Inc...................................................................................................................................17 Security/Ameritech.......................................................................................................................................18 Secuiron.........................................................................................................................................................18 Silent Knight Security Sysiems...................................................................................................................18 SpectronicsCorporation..............................................................................................................................18 Thorn...............................................................................................................................................................19 Tyco(Simplex-Grinnel,Wormald)...............................................................................................................19 WalterKidde...................................................................................................................................................ZO Westec............................................................................................................................................................Z(I Identifier Cross Reference List(Sorted by IdentifierJ ESL Detector ESL Base Detector Compatib/e Base Compatibility Identifier Compafibility Identi/ier Model Number S09A NA 429AT NA 5216/BXT(SW 1 On) NA S10A NA 429C NA 429CT NA 511 C NA 521 B/BXT(SW 1 Off) NA 521 NB NA 521 NBXT NA 521NCSXT NA S10A S00 711U/UT 701E,701U,702E,702U S10A S00 721U/UT 701E,701U,702E,702UN S11A NA 429CRT NA 429CST NA S11A NA 521CRXT NA 521NCRXT NA 521NCSRXT NA SitA S00 731U 701U,702E,702RE, 702RU,702U Identifier Cross Reference List(Sorted by Model NumberJ Detector ESL Detector Compatible Base ESL Base Model Number Compatibility Identifier Compatibility Identifier 429AT S09A NA NA 429C S10A NA NA 429CT S10A NA NA 429CRT S11 A NA NA 429CST S 11 A NA NA 511 C S 10A NA NA 5218/BXT(SW 1 On� S09A NA NA 5216/BXT(SW 1 Offl S10A NA NA 521CRXT S11A NA NA 521 NB/BXT S10A NA NA 521 NCSXT S10A NA NA 521NCSRXT S11A NA NA 521 NCRXT S11A NA NA 711U/UT S10A 701U,702E,702U S00 721U/UT S10A 701U,702E,702U S00 731U S11A 701U,702E,702RE,702RU,702U S00 Gf Security ESL Compatibility lndex-10/04 subject to change withoui notice Call FaxBack for latesi listings 800-483-2495 4 Ademco Contro/Unit Description Loop Control Detectors ESL Compatibility Style Unit ID# Per Circuit Identifier 4120EC B Household Fire 5 S09A 4140XM B Household fire 10 S09A 414{1XM Series�4140XMP,4140XMPT,4140XMPT-2) B Household Fire 20 S09A 5140XM Series B A 20 S09A FOCUS 200 PLUS B A 10 S09A Vista-15P B Household Fire 20 S09A Vista-20Nista-20P B Household Fire 20 S09A Vista-40 B Household Fire 20 S09A Vista-50 B Household Fire 20 S09A Vista-50PNista-50PEN/Vista-50PUL B Household Fire 20 SD9A Vlsta-100 B Household Fire 10 S09A ADT Security Systems, Inc. Contro!Unit Description Loop Control Detectors ESL Compatibility Style Unit ID# Per Circuit Identifier 4519-013,4519-313 A J1 10 S10A,S00 4520,Zone Model 4520-064 A G1 10 S10A,S00 4520,Zane Model 4520-084 B H1 13 S10A,S00 4520,Zone Model 4520-330 and/or A C1 15 S10A,S00 Zone Model 4520-331 4520,Zone Model 4520-130 A B1 15 S10A,S00 4520,Zane Model 4520-431 A A1 15 S10A,S00 4520,Zone Model 4520-230 A E1 15 S10A,S11A,S00 4520,Zone Model 4520-429 and/or D F1 10 S10A,S00 Zone Model 4520-529 4520,Zone Model 4520-430 and/or A D1 10 S10A,S11A,S00 Zone Model 4520-530 FOCUS 75 B A 20 S09A MCFAP-2Z3,2Z6 D 20 S10A,S00 w or w/o(-220�,Zone Model BPAC or IDCA MCFAP-1Z1,2Z1 B 20 S10A,S00 w or w/o(-220) MCFAP-2Z3,2Z6 B 20 S10A,S00 w or w/a(-220�,Zone Model w or w/o 21DC Unimode 2 Control Unit B,D A 18 S10A,S00 Unimode 4-16,Zone Model IZ-4 and/or B,D A 18 S10A,S00 Zone Model IZ-4A and/or Zone Model IZ8 Unimode 4-16/II,Zone Model IZ4;8 and/or IZM-8 20 Zone ID with or without IZE Unimode 5 B,D 20 S10A,S00 Unimode 10 B,D 20 S10A,S00 Unimode 200,Zone Model M302 B,D 24 S10A,S11A,S00 Safewatch P3000 B 20 StOA/S11A/S00 Ad vantor Control Unit Description Loop Contro/ Detectors ESL Compatibility Style Unit ID# Per Circuit Identi/ier Advantage A 16 S10A,S00 ULF-3000-24 GESecurity ESL Compatibility Index-10/04 subject to change without notice Call FaxBack for latesi listings 800-483-2495 : 5 Alison Control, Inc. � Control Unit Description Loop Control Detectors ESL Compatibility Style Unit ID# Per Circuit Identifier A888-MXXX,Zane Mode1108800-2 B,D 002 25 S10A,S00 A888-MXXX,Zone Mode1108800-2 B,D 002 50 S10,SOO,S02 Aritech (see GE Security) Auth Company Conhol Unit Description Loop Contro/ Detectors ESL Compatibility Sty/e Unit ID# Per Circuit Identifier : AFC 100,Zone Madel PCB 160 B 026 30 S10A,S11A,S00 AFC 100,Zone Madel PCB 173 D 027 30 S10A,S1 tA,S00 AFC 100,Zone Madel PCB 175 B 025 30 S10A,S11A,S00 AFC 400C,Zone Madel SMD-2 B,D 024 30 S10A,S11A,S00 Autocall Corporation, A Division of Thorn Automated Systems Control Unit Description Loop Control Detectors ESL Compatibility Style Unit lD# Per Ciicuit Identifier AC-Ii,Zone Model 5130-074-21 D 01A 20 S10A,511A,S00 AC-II,Zone Model 5200-522 B 01A 20 S10A,S11A,S00 AC-II,Zone Models 5130-106-10 B 01A 30 S10A,S11A,S00 ar5200-433 AC-II,Zone Model 5200-432 D 01A 30 S10A,S11A,S00 AC-II,Zone Model 5200-521 B 01A 12 S10A,S11A,S00 AC-II,Zone Model 5130-521 B 01A 12 StOA,St tA,S00 CD-NA,Zone Model 5200-432 D 01A 30 S10A,S11A,S00 CD-NA,Zone Madel 5200-433 B 01A 30 S10A,St tA,S00 CD-TXA,Zone Model 5130-074-21 D 01A 20 StOA,S11A,S00 CD-TXA,Zone Madel 5200-522 B 01A 20 S10A,S11A,S00 CD-TXA,Zone Model 5130-106-10 B 01A 60 S10A,S11A,S00 or5200-433 CD-TXA,Zone Model 5200-432 D 01A 60 S10A,S11A,SO CD-TXA,Zone Mode15200-521 B 01A 12 S10A,S11A,S00 CD-XA,Zone Made15200-522 B 01A 20 S10A,S11A,S00 CD-XA,Zone Mode15130-074-21 D OtA 20 S10A,S11A,S00 CD-XA,Zone Mode15200-521 B 01A 12 S10A,S11A,S00 CD-XA,Zone Madel 5130-106-10 B 01A 30 StOA,S11A,S00 CD-XA,51200-433 B 01A 30 S10A,S11A,S00 CD-XA,Zane Mode15200-432 D OtA 30 S10A,S11A,S00 MDK,Zone Madel 5130-044-02 B 01A 30 S10A,S11A,S00 MDK,Zone Madel 5130-044-03 B 01A 30 S10A,S11A,S00 MDK,Zone Model 5130-106-10 B 01A 30 S10A,S11A,S00 MD2K,Zane Model 5130-044-02 B 01A 30 S10A,S11A,S00 MD2K,Zone Model 5130-044-03 B 01A 30 S10A,S11A,S00 MD2K,Zone Model 5130-106-10 B OtA 30 S10A,S11A,S00 MDK,Zone Model 5130-044-04 B 01A 30 S10A,S11A,S00 GE Security ESL Compatibility lndex-10/04 subject to change withoui notice Cail FaxBack for latesi lisiings 800-483-2495 6 Autocall Corporation, A Division of Thorn Automated Systems (continuedl Contro/Unit Description Loop Contro/ Detectors ESL Compatibility Style Unit ID# Per Circuii Identifier MDK,Zone Model 5130-044-05 8 OtA 30 S10A,S11A,S00 MD2K,Zone Model 5130-044-04 D 01A 30 S10A,S11A,S00 MD2K,Zone Model 5130-044-05 D 01A 30 S10A,S11A,S00 MEALIN Control Unit,Zone Models B 01A 30 S10A,S11A,S00 5130-106-10 or5200-433 MERLIN Control Unit,Zone Models D 01A 30 S10A,S11A,S00 5130-432 ar5200-432 MP400,Zone Model 5130-074-21 D 01A 20 S10A,S11A,S00 MP400,Zone Model 5130-106-10 B 01A 30 S10A,S11A,S00 MP400,Zone Model 5200-433 B 01A 30 S10A,S11A,S00 MP400,Zone Madel 5200-432 D 01A 30 S10A,S11A,S00 MP400,Zone Madel 5200-521 B 01A 12 S10A,S11A,S00 FIREQUEST 100-12 B 10112A 7 S10A,S00 FIREQUEST 200,Zone Model 2ZX B,D 200A 22 S10A,S11A,S00 FIREQUEST 200,Zone Model 4ZX,4ZXD B 200A 22 S10A,S11 A,S00 or COMM CONT.AEV.W FIREQUEST 200,Zone Model U B,D 200X 22 S10A,S11 A,S00 FIREQUEST 200,Zone Model MASTER HALON B,D 200A 22 S10A,S11 A,S00 FIREQUEST 200,Zone Model VSO B,D 200A 30 S10A,S11 A,S00 FIREQUEST 300,Zone Model with or w/o DIB B,D F2 S10A,S11 A,S00 K-101-24 B,D 10124A 30 S10A,S11A,S00 KDR-1000,Zone Madel AIZ or AIZ-2 D 1000A 30 S10A,S11A,S00 KDA-1000,Zone Model BIZ-t,BIZ-2,BIZ-5 B 1000A 30 S10A,S11A,S00 KDR-1000,Zone Model DZM B 10008 30 S10A,S11A,S00 KDR-1000,Zone Model MIZP B 1000C 30 S10A,S11A,S00 Burle Industries All panels No 2-wire fire loops,use 4-wire models or ESL 505 2 to 4 wire converter module C& K Systems �i�c.J Control Unit Description Loop Control Detectors ESL Compatibility Style Unit lD# Per Circuit Identi/ier SYS238 Series B Household fire 12 S09A SYS2316 Series B Household Fire 12 S09A Cerberus Pyrotronics Control Unit Description Loop Control Detectors ESL Compatibility Style Unit ID# Per Circuit Identi/ier CP-2HR A,B,D CP-2HR 30 S10A,S11A,S00 CP-35 A,B,D CP-35 30 S10A,S11A,S00 CP-35,Zone Model ZU-35 A,B,D ZU-35 30 S10A,S1 tA,S00 CP-35,Zone Model ZU-35DS A,B,D ZU-35DS 30 S10A,S1 tA,S00 CP-35,Zone ModeIZU-35TS A,B,D ZU-35TS 30 S10A,S11A,S00 CP-400 B CP-400 30 S10A,S11A,S00 CP-400,Zone Model ZNE-404 B ZN-4�4 30 S10A,S11A,S00 GE Security ESL Compatibility lndex-10/04 subjeci to change without notice Call FaxBack for latest lisiings 800-483-1495 7 Cerberus Pyrotronics (Continued.) : Control Unit Description Loop Control Detectors ESL Compatibility Style Unit ID# Per Circait ldentifier CP-400,Zone Model ZNE-404/S B ZNE404/S 30 S10A,S11A,S00 CP-400,Zone Model 405A D 405A 30 S10A,S11A,S00 CTI-1,Zone Model 30774-02 B 30774-02 25 S10A,S11A,S00 CTI-1,Zone Model 30774-03 B 30774-03 25 S10A,S11A,S00 IXL with CZI-H2S B P/N-02,P/N-03 25 S10A,S00 IXL with CZI-H4S D P/N-01,30774 25 S10A,S00 MX-316 A,B,D MX-316 30 StOA,S11A,S00 MXL,with CZA-1,CZR-4 B,D CZM-1 20 S10A,S00 CZM-4 20 S10A,S00 SXL with or without SZE-4R B Model No. 25 S10A,S00 XL-3,Zone Mode�ZNX-3 A,B,D ZNX-3 30 S10A,S11A,S00 Detection Systems, lnc. Conhol Unit Description Loop Controi Detectors ESL Compatibility SYyle Unit ID# Per Circuit Identifier D7024 Series with D7014/DS9411 D B 20 S10A,S11 A,S00 : DS7090 Series 8 Household Fire 16 S09A DS7090i Series;and DS7090TMi B B1 20 S10A,S00 DS7100 Series B B 16 S09A DS7100 Series with DS7110 B B1 16 S09A DS7400 Series with DS7433 B C 20 S10A DS9400 Series with D7014/DS9411 D B 20 S10A,S11A,S00 Digital Monitoring Products, Inc. (DMPJ . Control Unit Description Loop Control Detectors ESL Compatibility Style Unit ID# Per Circuit Identifier 1512 control,Zone Madel 715,or Zone 5 A A 12 S09A 1812A,Zone Mode1705 B CI-1 10 S10A,S00 1812B,Zone Model 705 B CI-1 10 S10A,S00 1812C,Zone Mode1705 B CI-1 10 S10A,S00 1812D,Zone Mode1705 B CI-1 10 S10A,S00 1812E,Zone Model 705 B CI-1 10 S10A,S00 . 1912 control,Zone Model 715,or Zone 5 A A 12 S09A 1912XR control,Zone Model 715,or Zone 5 A A 12 S09A XR5SL,Zone Model 2-5 on XR5SL control tCleanMe A A 12 S09A XR5FC,Zone Model 2-5 on XR5FC control A A 12 S09A XR20,Zone Model 715,715-8,715-16 A A 12 S09A or zone 10 on XR20 control �CleanMe XR10,Zone Model 715,715-8,715-16 wCeanMe A A 12 S09A or zonel0 on XR10 control � ����••�••� XA200,Zone Model 715,715-5,715-16 A A 12 S09A or zone 9&10 on XR200 NC�eanMe GESecurity ESL Compatibility Index-10/04 subject to change wiihout notice Call FaxBack ior latest lisiings 800-483-1495 8 Digital Security Controls �oscl Control Unit Description Loop Control Detectors ESL Compatibility Style Unit lD# Per Circuit Identifier 4020CF B 30 S09A PC5010 B 15 S09A PC4010CF B FM-1 30 S09A PC4020CF B FM-1 30 S09A PC50101Power832) B PC5.1 30 S09A PC1575 B PC15.1 30 S09A Edwards (Edwards Systems Technology) Control Unit Description Loop Control Detectors ESL Compatibility Style Unit ID# Per Ci�cuit Identi/ier 12118 B,D 001 15 S10A,S11A,S00 12126 B,D 001 15 S10A,S11A,S00 12148 B 001 15 S10A,S11A,S00 2400(2412,2414,2418) B 20 S10A,S00 Zone Model 2400-21DC(2400-2101) 2400(2412,2414,2418) D 20 S10A,S00 Zone Model 2400-2BPA or 2400-IDCA (2400-2104,2400-2105) 57218,Zone Model 5703B-105,or 5703B-405 D 001 20 S10A,S11A,S00 5721 B,Zone Model 5703B-122, B 001 20 S10A,S11 A,S00 or5703B-402,or5703B-406 5751B B,D 001 20 S10A,S11A,S00 5752B,Zone Model 5750B-102 B 001 20 S10A,S11A,S00 57526,Zone Model 57506-105 D 001 20 S10A,S11A,S00 5753B,Zone Model 57506-102 B 001 20 S10A,S11A,S00 5753B,Zone Model 57506-105 D 001 20 S10A,S11A,S00 57548 B 001 20 S10A,S11A,S00 57548-2Z B 001 20 S10A,S11A,S00 5756B B,D 001 20 S10A,S11A,S00 57828 8,D 001 20 S10A,S11A,S00 5800,Zone Model 5703-R2,5703-R5 B,D 001 25 S10A,S11A,S00 6602-B201 B 660201 30 S10A,S11A,S00 6604-B201 B 660201 30 S10A,S11A,S00 6602-B201,Zone Mode16602-B102 D 660201 30 S10A,S11A,S00 6604-B201,Zone Mode16602-6102 D 660201 30 S10A,S11A,S00 6616,Zone Model 6616-301,or 6616-303 B 660201 18 S10A,S11A,S00 6616,Zone Model 6616-304 D 660201 18 StOA,S11A,S00 6632,Zone Mode16616-301,or6616-303 B 660201 18 S10A,S11A,S00 6632,Zone Mode16616-304 D 660201 18 S10A,S11A,S00 8500,Zone Model 8501-X341,or 8501-X381 B 85001 20 S10A,S11A,S00 8500,Zone Model 8501-X342,or 8501-X382 D 85002 20 S10A,S11A,S00 8500,Zone Model 8501-X343,or 8501-X383 8 85003 20 S10A,S11A,S00 8570-ESAC,Zone Model 8572-X201 B 857001 30 S10A,S11A,S00 8570-ESAC,Zone Mode18572-X202 D 857002 30 S10A,S11A,S00 IRC-1,Zone Model 130022 B,D 5876 30 S10A,S11A,S00 IRC-3,Zone Model 130108 or 240113,or 240119 B 3289B 30 S10A,S11A,S00 IRC-3,Zane Mode1130082 B,D 3289A 30 S10A,S11A,S00 GE Security ESL Compatibility Index-10/04 subject to change without notice Call FaxBack for latesi listings 800-483-7495 9 Edwards (Edwards Systems Technology)(Continuedl Control Ueit Description Loop Conho/ Detectors ESL Compatibility Style Unit 1D# Per Circuit ldentifier IRC-3,Zone Model 240205 B 5389 24 S10A,S11A,S00 LSS1,Zone Model 4CLA,4ZEXP B,D 0.0 30 S10A,S00 LSS4,Zone Model 4CLA,4ZPXP B,D 0.0 30 S10A,S00 LSS1/12,Zone Model 4CLA,4ZEXP B,D 0.0 30 S10A,S00 LSS4/12,Zone Model 4CLA,4ZEXP B,D 0.0 30 S10A,S00 RZ812-6MFC,Zone Model 240205 B 5389 24 StOA,S11A.S00 ESL(see GE Security) Ellenco Inc. Cantrol Unit Description Loop Contro/ Detectors ESL Compatibility Style Unit ID# Per Circuit /dentifier PMS,Zone Model MCP-1 B ZEI-01 15 S10A,S00 ' PMS,Zone Model ZE-2A B,D ZEI-04 15 S10A,S00 PMSJR-1 B,D ZEI-03 15 S10A,S00 PMSJA-2 B,D ZEI-03 15 S10A,S00 ECP-2000,Zone Model 401310/401311/401312 B 30 S10A,S00 Farada y, Inc. Contro/Unit Description Loop Controf Detectors ESL Compatibility Style Unit ID# Per Circuit Identifier FA200 B,D 30 S10A,S1 tA,S00 852 B FOS1 30 S10A,S11A,S00 854 B FOS1 30 S10A,S11A,S00 MPC-2000,Zone Model ZN-1,ZN2 and ZN-3 B,D D 15 S10A,S00 7800,Zone Mode17836 B,D B 40 S10A,S11A 12400 B G 25 S10A.S00 1Z500,Zone Model 12503 B M 30 S10A,S00 13200 B F 30 S10A,S00 13400 B G 30 St0A,S00 15108A,151086 B,D A 30 S10A,S11A,S00 15108AL,15108BL B,D FOS2 15 S10A,S11A,S00 15112A,15112B B,D A 30 S10A,S11A,S00 15112AL,151126L B,D fOS2 15 S10A,S11A,S00 15116A,15116B B,D A 30 S10A,S11A,S00 15116AL,15116BL B,D FOS2 30 S10A,S11A,S00 15220A B C 30 S10A,S00 15240A B C 30 S10A,S00 19000A B,D B 30 S10A,S11A,S00 19000A,Zone Model 401126 or 401127 B,D B 40 S10A,S11A,S00 19000A EVAC,Zone Madel 401126 B,D B 30 S10A,S11A,S00 GE Security ESL Compatibiliry Index-10/04 subjeci to change without notice Call FaxBack for latesi listings 800-483-2495 10 Federal Signal Corporation Control Unit Description Loop Control Detectors ESL Compatibility Style Unit ID# Per Circuit Identifier Firelarm 2000 B CP01 25 S10A,S00 Firelarm 3000 B MF24A 30 S10A,S11A,S00 4000,Zone Model 5130-044-02 or 5130-044-03 B 01A 30 S10A,S11A,S00 4000,Zone Model 5130-044-04 or 5130-044-05 D 01A 30 S10A,S11A,S00 6000,Zone Model 5130-044-02 or 5130-044-03 B 01A 30 S10A,S11A,S00 6000,Zone Model 5130-044-04 or 5130-044-05 D 01A 30 StOA.S11A,S00 8000,Zone Model 5130-044-02 or 5130-044-03 B 01A 30 S10A,S11A,S00 B000,Zone Model 5130-044-04 or 5130-044-05 D 01A 30 S10A,S11A,S00 Fire Burglary Mstruments �Fa�il All panels No 2-wire fire loops,use 4-wire models or ESL 505 2 to 4 wire converter module Firecom, Inc. Contiol Unit Description Loop Control Detectors ESL Compatability Style Unit ID# Per Ci�cuit Identi/ier 8500,Zone Mode1791A D 021 15 S10A,S11A,S00 8500,Zane Mode1791VA D 022 15 S10A,S11A,S00 8500,Zone Mode1791B B 020 30 S10A,S11A,S00 8500,Zone Mode1791VB B 023 30 S10A,S11A,S00 Fire Control Instruments Control Unit Description Loop Contro/ Detectors ESL Compatibility Style Unit ID# Per Circuit Identifier FC-72,Zone Model VZM A,B VZM01 25 S10A,S11A,S00 FC-72,Zone Model ZDM A,B ZDM01 25 S10A,S11A,S00 FC-72,Zone Model ZDM-D A,B ZDMD01 25 S10A,S11A,S00 FC-72,Zone Model VZM D VZM01Z 20 S10A,S11A,S00 FC-72,Zone Model ZDM D ZDMD01 20 S10A,S11A,S00 FC-72,Zone Model ZDM-D D ZDMD01 20 S10A,S11A,S00 FC-ID,Zone Model CPD-ID A,B CPDID-1 1 S10A,S11A,S00 FC-ID,Zone Model SLM A,B SLMOt 10 S10A,S11A,S00 SBP-2,Zone Model SBP-2 A,B SBP01 25 S10A,S11A,S00 SBP-4,Zone Model SBP-4 A,B SBP01 25 S10A,S11A,S00 Firelite Control Unit Description Loop Control Detectors ESL Compatibility Sty/e Unit ID# Per Circuit Identifier AE-1 or AE-2 with Zone Model ZAB B,D A 12 S10A,S11A,S00 MP-12 B A 20 S10A,S00 MP-24 B A 20 S10A,S11A,S00 MP-4424 B,D A 20 S10A,S00 MRF-4424 B,D A 20 S10A,S00 MS-124,MS-424 B A 20 S10A,S11A,S00 MS-4024 B A 20 S10A,S11A,S00 GESecurity ESL Compatibility Index-10/04 subjec[to change without notice Call FaxBack for latesi lisiings 800-483-2495 11 Firelite (Continued) Contiol Unit Description Loop Control Detectors ESL Compatibility Style Unit ID# Per Circuit Identifier MS-424A,Zone Model ANC-2B,CUG2 or WFC B,D A 25 S10A,S11A,S00 MS-4412B B A 20 St0A,S00 MS-4424B B,D A 20 S10A,S00 MS-4824,Zone Model IZ424 B,D A 20 S10A,S11A,S00 MS-5012 B A 20 S10A,S00 MS-5024 B A 20 S10A,S00 MS-5024UD:with or w/o CAC-10F B,D A 20 S10A,S00 MS-5210UD,Zone Model:with or w/o CAC-10F B,D A 20 S09A,S10A,S00,S11A, MS-5224UD,Zone Madel B,D A 20 S10A,S00 MS-9200,Zone Model M302 B,D A 24 S09A,StOA,S00,S11A Sensiscan 2000,Zone Model IZF-S or IZE-A B,D A 30 S10A,S11A,S00 Sensiscan 2000,Zone Model IZ-8F, B,D A 20 S10A,St 1A,S00 or IZE-AF,IZ-4F,IZ-4AF 5000,Zone Model IZ-BF or IMZ-A B,D A 25 S10A,S11A,S00 First Alert Control Unit Description Loop Contro/ Detectors ESL Compatability Style Unit ID� Per Circuit Identifier FA200C B Household Fire 5 S09A,S10A,S11A FA1200C B Household Fire 20 S09A,S10A,S11A FA1500C B Household Fire 20 S09A,S10A,S11A Gamewell Control Unit Description Loop Contro/ Detectors ESL Compatibility Style Unit ID# Per Circuit ldenfifier FLEX 300,Zone Model Z2V D Z2V 25 S10A,S11 A,S00 FLEX 300,Zane Model Z3A D Z3A 25 S10A,S11 A,S00 FLEX 300,Zone Model Z46 B Z4B 25 S10A,S11A,S00 iNS-2,Zone Model 30774-02,or 30774-03 B Model No. 25 S10A,S11A,S00 ZANS 400,Zone Model Z1 B,D 30635 25 S10A,S11 A,S00 GE Security Control Unit Description Loop Contro/ Detectors ESL Compatibility Style Unit ID# Per Circuit ldentifier Aritech-D 5000 B D5000A 20 S09A,S10A,S00 Aritech-D3000,OEM 48 A 20 S09A,S10A,S00 ESL 1501,Zone Model BMB,VTW ar ZEM B,D C01A 20 S10A,S11A,S00 ESL 1503,Zone Model BMB,VTW or ZEM B.D COtA 20 S10A,S11A,S00 ESL 1505,Zone Model BMB,VTW or ZEM B,D COtA 20 S10A,S11A,S00 ESL 1501,Zone Model BMB,VTW ar ZEM B,D COt 20 S10A,S11A,S00 ESL 1503,Zone Model BMB,VTW or ZEM B,D C01 20 StOA,St tA,S00 ESL 1505,Zone Model BMB,VTVU or ZEM B,D C01 20 S10A,S11A,S00 ESL 2500,Zone Model 2501 Zone 1 D 2500 20 S09A,S10A,S00 ESL 2500,Zone Model 2502-ZEM �CleanMe D 2500 20 S09A,S10A,S00 GE Security ESL Compatibility Index-10/04 subjeci fo change withoui notice Call FaxBack for latesi lisiings 800-483-1495 12 GE Security(Continued) Control Unit Description Loop Control Defectors ESL Compatibility Style Unit ID# Per Ciicuit Identi/ier ESL 2500,Zone Model 2504-ZEM A 2500 20 S09A,S10A,S00 ' ESL 505,2 to 4 wire Converter Module �CleanMe B 20 S09A,S10A,S11 A,S00 Concord Hybrid,Zone Model 8Z Expander A 60-734 10 S09A SnapCard 60-757 or 4A Input/2Z Output 60-756 ; Concord AF16,Zone Mode18Z Expander A 60-792-95R-16Z 10 S09A SnapCard 60-757 or 4A Input/2Z Output 60-756 Concord AF32,Zone Mode18Z Expander A 60-792-95R-32Z 10 S09A SnapCard 60-757 or 4A Input/2Z Output 60-756 Concord Commercial,Zone Model 8Z Expander A 60-801 10 S09A SnapCard 60-757 or 4A Input/2Z Output 60-756 Concord Express,Zane Model 8Z B 60-806-95R,60-806 10 S09A SnapCard 60-757 or 4A Input/2Z Output 60-756 Concord Hybrid,Zone Model 8Z Expander with SnapCard A 60-734 10 StOA 60-757 or 10 60-756 and with 60-S10A-MOD Concord RF16,Zone Model 8Z Expander with SnapCard A 60-792-95R-16Z 10 S10A 60-757 or 10 60-756 and with 60-S10A-MOD Concord RF32,Zone Model 8Z Expander with SnapCard A 60-792-95R-32Z 10 S10A 60-757 or 10 60-756 and with 60-S10A-MOD Concord Commercial,Zone Model 8Z Expander with A 60-801 10 S10A SnapCard 60-757 or 10 60-756 and with 60-S10A-MOD Concord Express,Zone Model 8Z Expander with B 60-806-95R,60-806 10 S10A SnapCard 60-757 or 10 60-756 and with 60-S10A-MOD Advent,Zone Model A 60-562 10 S09A 60-757,60-758,60-756 or 60-767 �CleanMe Advent,no Zone Models �C1eanMe A 60-562 20 S09A Advent w/Zone Models 60-757,60-758, A 60-562 10 S10A 60-756 or 60-767 and with 60-S10A-MOD �mleanMe Advent,no Zone Models with a 60-S10A-MOD aCleanMe A 60-562 20 S10A Moose-Z1200 B Z1200A 20 S09A,S10A,S00 Moose-Z2000 B Z2000A 20 S09A,S10A,S00 Moose-Z1250 A Z1250 20 S09A,S10A,S00 Moose-ZX200/210 A ZX200/210 10 S09A,S10A,S00 Maose-ZS300/310 A ZX300/310 10 S09A,S10A,S00 Moose-Z2000,Madel Z2000,Z1200 A ZX2000 20 S09A,S10A,S00 Moose-ZX400/410 A ZX400/410 20 S09A,S10A,S00 Moose-Model ZXEXP A 10 S09A,S10A,S00 NetworX NX-4 B 3800-0001 20 S09A NetworX NX-6 B 3800-0001 20 S09A NetworX NX-8&NX-S-CF B 3800-0001 20 S09A NetworX NX-8E B 3800-0001 20 S09A NetworX 8900 EUL B 3800-0001 20 S09A : Harrington Signal Control Unit Description Loop Contro/ Detectors ESL Compatibility Style Unff ID A� Per Circuit Identi/ier HS-2200 B,D 25 S10A HS-2400 B,D 25 S10A HS-3000B,with 281,481,BIN,BX,BXIN B 30 S10A HS-3000V,with 261,4BI,BIN,BX,BXIN B 30 S10A GE Security ESL Compatibility lndex-10/04 subject fo change without notice Call FaxBack for latest listings 800-483-2495 13 Honeywell, Inc. Control Unit Description Loop Control Detectors ESL Compatibility Style Unit ID# Per Circuit Identifier DELTANET F&S,Zone Model AA A,B,C 001 25 S10A,S11A,S00 DELTANET F&S,Zone Madel AB D,E 001 25 S10A,S11A,S00 SENTARA 324,Zone Model W1065A A,B,C 006 20 S10A,S11A,S00 SENTARA 324,Zone Model W1065A D,E 006 20 S10A,S11A,S00 5900 Series A A 12 S09A 7000 Series B 7K8 10 S09A ITI(see GESecuriryl Johnson Controls, Inc. : Control Unit Description Loop Control Detectors ESL Compatibilily Style Unit ID# Per Circuit ldentifier MULTIPLEX 5000,Zone Madel UZM D VZM01 25 S10A,S11A,S00 MULTIPLEX 5000,Zone Model ZDM D ZDM01 25 S10A,S11A,S00 MULTIPLEX 5000,Zone Model ZDM-D D ZDMD01 25 S10A,S11A,S00 MULTIPLEX 5000,Zone Model VZM A,B VZM01 20 S10A,S11A,S00 MULTIPLEX 5000,Zone Model ZDM A,B ZDMOt 20 S10A,S11A,S00 MULTIPLEX 5000,Zone Model ZDM-D A,8 ZDMD01 20 S10A,St tA,S00 SYSTEM 5000,Zone Model VZM D VZMOt 20 S10A,S11A,S00 SYSTEM 5000,Zone Model ZDM D ZDM01 20 StOA,S1 tA,S00 SYSTEM 5000,Zone Model ZDM-D D ZDMD01 20 S10A,S11A,S00 SYSTEM 5000,Zone Model VZM A,B VZM01 25 S10A,S11A,S00 SYSTEM 5000,Zone Model ZDM A,B ZDM01 25 S10A,S11A,S00 SYSTEM 5000,Zone Model ZDM-D A,B ZDMD01 25 S10A,S11A,S00 Land►s& GYR(MCC PowersJ Conbol Unit Description Loop Contro/ Detectors ESL Campatibility SYyle Unit ID# Per Circuit /dentifier SYSTEM 600/fMS,Zone RCU/533-150 B,D 533150 18 S10A,S11A,S00 . Mirtone Control Unit Description Loop Contro/ Detectors ESL Compatibility Style Unit lD# Per Circuit Identifier ' 7100,ar7112 B A 30 S10A,S11A,S00 7200 B A 30 StOA,S11A,S00 7200,Zone Mode17230 D A 30 S10A,S11A,S00 7600,or 7800 B A 30 S10A,S11 A,S00 7600,Zone Madel 7602 B A 30 S10A,S11 A,S00 7600,Zone Mode17630 or 7640 D A 30 S10A,S11 A,S00 7800,Zone Mode17602 B A 30 S10A,S11A,S00 7800,Zone Mode17630 or 7640 D A 30 S10A,S11A,S00 7900,Zone Models 79045-2,or 79045A-2TA B A 13 StOA,S00 7900,Zone Mode179044A D A 13 S10A,S00 79002U,Zone Model 79096U-2,79045-21A, B A 30 S10A,S11A,S00 79110,79110D,79111 GE Security ESL Compatibility Index-10/04 subject to change wiihout notice CaII FaxBack for latest listings 800-483-1495 14 Mirtone (Continued) Control Unit Description Loop Control Detectors ESL Compatibility Style Unit ID# Per Circuif Idenfi/ier 79008U,Zone Mode179096U-2,79045-21A, B A 30 S10A,S11A,S00 79110,79110D,79111 79029,Zone Mode179096U-2,79045-21A, B A 30 S10A,S11A,S00 79110,79110D,or79111 79030,Zone Mode179096U-2,79045-21A, B A 30 S10A,S11A,S00 79110,79110D,or 79111 79096U,Zone Madel 79096U-2,79045-21A, B A 3D S10A,S11A,S00 79110,79110D,or 79111 79500,Zone Mode179096U-2,79045-21A, 8 A 30 S10A,S11A,S00 79110,79110D,or 79111 79500U-CA,Zone Mode179096U-2,79045-21A, B A 30 S10A,S11A,S00 79110,79110D,or 79111 8000,Zone Models 8070,8071,8072,8073, B A 30 S10A,S11A,S00 8070A,8071A,8072A,8073A 8000,Zone Models 7630 or 7640 D A 30 S10A,S11A,S00 9200,Zone Models 8070,8071,8072,8073, B A 30 S10A,S11A,S00 8070A,8071A,8072A,8073A 9200,Zone Models 7630 or 7640 D A 30 S10A,S11A,S00 9200 Remote,Zone Models 7630,or 7640 D B 30 S10A,S11A,S00 9200 Remate,Zone Models 8070,8071,8072 B A 30 S10A,S11A,S00 8073,8070A,8071A,8072A,or8073A 9500,Zone Models 7630,or 7640 D B 13 S10A,S11A,S00 9500,Zone Models 8070,8071,8072, B A 13 S10A,St tA,S00 8073,8070A,8071 A,8072A,or 8073A NIOOSe(see GE Security) Napco Security Systems Control Unit Description Loop Control Detectors ESL Compatibility Style Unit lD# Per Circuit Identifier MA-1000 Series B Household Fire 10 S09A MA-1008 Series B Household Fire 10 S09A MA-1010 Series B Household Fire 10 S09A MA-1016 Series B Household Fire 10 S09A MA3000 SERIES B MA3000A and 10 S10A,S00 MA3000B MFA-6012,Zone Madel with B,D MF12A 10 S09A or without CA6000 MFA-6024 Series,Zone Model with B,D MF24A 30 S10A,S11A,S00 ar without CA6000 S5500 SERIES B S5000A and 10 S10A,S00 S5000B Gem-P3200 �CleanMe B 6EM-PS 10 S09A Gem-P9600 � `""""` B GEM-PS 10 S09A National Guardian Control Unit Description Loop Control Detectors ESL Compatibility Style Unit ID# Per Circuit /dentifier CONTROLINK 5200,Zone Models ZN-1, B,D D 15 S10A,S00 ZN-2,ZN-3 3100 Series,Zone Model 7433 B C 20 S10A,S00 GE Security ESL Compatibility Index-10/04 subject to change without notice Call FaxBack for latest lisiings 800-483-2495 15 NefinrorX(see GE Security) Notifier ' Control Unit Description Loop Contro/ Detectors ESL Compatibility Style Unit ID# Per Circuit Identi6er AFC-90,Zone IZA424 B,D A 20 S10A,S00 AFM-200,Zone Model IMMX-2,or M3-TW B,D A 25 S10A,S00 AFP-1010,Zone Model IMMX-2,or M3-NV B,D A 25 S10A,S00 AFP-200,Zone Madel IMMX-2,or M3-TW B,D A 25 S10A,S00 AM-2020,Zone Model IMMX-2,or M3-TW B,D A 25 S10A,S00 SFP-2,SFP-4,SFP-6&SFP-8 B,D A 24 S10A,S11A,S00 SFP-400 B,D A 25 S10A,S00 : SGL-1000,SGL-4000 B A 24 S10A,S11A,S00 System 500,Zone Model IZ-BF,or B,D A 20 S10A,S00 IZ-4F,IZE-AF,IZ-4AF S500,Zone Madel IZM-8 or IZE-A B,D A 30 S10A,S11A,S00 S5000 ar S500,Zone Model IZM-8 or IZE-A B,D A 30 S10A,S11A,S00 XP Transponder,Zone Model XPM-8 B,D A 40 S10A,S00 4800,Zone Madel 2Z2W-A or 4Z2W-B B A 24 S10A,S11A,S00 4885,Zone Model 2Z2W-A or 4Z2W-B B A 24 S10A,S1 tA,S00 Optex Morse, Inc. Conhol Unit Description Loop Control Detectors ESL Compatibility Style Unit ID# Per Circuit ldentifier G824 Series B 5000-04t18 10 S10A,S00 MDC Series No 2-wire fire loops,use 4-wire models ar ESL 505 2 ta 4 wire converter module : Pem-All Fire Extinguisher Corporation Control Unit Description Loop Contro/ Detectors ESL Compatibility Style Unit ID# Per Circuit ldentifier PEM-5000,Zone Model IMZ-8,IZE-A B,D A 30 S10A,S11A,S00 Potter Electric Signal Company Conhol Unit Description Loop Control Detectors ESL Compatibility Style Unit ID A� Per Circuit ldentifier PFC 100 B A 15 S10A,S00 PFC t00R,PFC-2000,PFC-4000 B,D A 25 S10A,S00 PFC 2000A B,D A 20 S10A,S00 System One/15,Zone Model BAIN,BAIXN, B,D PNV 30 S10A,S00 BBIN,BBIXN,BZAI,BZAIX,BZN-21AX,BZBI,BZBIX System One/15,Zone Model VAIN,VAIXN, D PV 30 S10A,S00 VBIN,VBIXN,VZAI,VZAIX,VZBI,BZBIX,VZN-21AX � Protectowire Company Control Unit Description Loop Control Detectors ESL Compatibility SYyle Unit ID# Per Circuit Identi/ier ACR-1600,Zone Model ZM-2200 A,D ZM-2200 10 S10A,S11A,S00 GE Security ESL Compatibility Index-10/04 subjeci to change wiihoui notice Call FaxBack for latesi listings 800-483-2495 f6 Radionics, Inc. Control Unit Description Loop Control Detectors ESL Compatibility Style Unit ID# Per Circuit Identifier D2012,Zone 1 A 10 S11A D2012U,Zone 1 A 10 S11A 02112 with or w/o D125B A A 5 S09A,S10A,St 1A D2112-01 10 S09A,S10A,S11A D2212 B 5 S09A D2212B,Zone 1 A 10 S11A D2412,Zone 1 A 10 S11A D2412U,Zone 1 A 10 S11A D2412EU A 10 S11A D2812 A A/B 5/15 S09A,S10A,S11A D2812U,Zone 1 A 10 S11A D4112 A B 12 S09A D6112 A B 12 S09A D7112,Zone Model D125,ar D1256(12V) A A 12 S09A D7112,Zane Model D1256�24V� A A 48 S10A,S00 D7212,Zone Model D125,or D1256(12V) A A 12 S09A D7212,Zone Model D1256�24V) A A 48 StOA,S00 D8112,Zone Model D125,or D125B(12V) A A 12 S09A D8112,Zone Model D1256(24V) A A 48 S10A,S00 , D9112,Zone Model D125,ar Dt 25B�12V) A A 12 S09A D9112,Zane ModeID1256124V) A A 48 S10A,S00 D9412 with or w/o D125B SO DS22128 A A 10 S10A,S11A D7412 Safetech, Inc. Control Unit Description Loop Contro/ Detectors ESL Compatibility Style Unit ID# Per Circuit Identifier S1000 B,D 40 S10A,S11A,S00 S1005 B 40 S10A S1010 B 40 S10A ' S2000,Zone Madel CCA-1,CCA-3,or DZM B,D CO2 40 S10A,S11A,S00 S2000,Zane Madel DZS B,D CO2A 40 S10A,S11A,S00 S3000 1�IeanMe B,D 40 S10A,S11A,S00 Scantronic (USA), INC. Control Unit Description Loop Control Detectors ESL Compatibility Style Unit ID# Per Circuit Identifier AV9000 Series,Zone FM2000 B Household Fire 20 S09A ELB,Zone FM2000 B Household Fire 20 S09A EL16,Zone FMZ000 B Household Fire 20 S09A SC1600 Series,Zone FM2000 B Househald Fire 20 S09A SC8000 Series,Zone FM2000 B Household Fire 20 S09A GE Security ESL Compatibiliry lndex-10/04 subject to change without notice Call FaxBack for latesi listings 800-483-2495 17 �� � f Securitylink/Ameritech Conhol Unit Description Loop Control Detectors ESL Compatibility Style Unit ID# Per Circuii Identifier AM-100 B Household Fire 20 S09A SL 150 B Household Fire 20 S09A Secutron Control Unit Description Loap Control Detectors ESL Compatibility Style Unit ID# Per Circuit Identifier MR-2900,with MR-2928 or 2938 B,D 40 S10A,S11 A Silent Knight Security Systems ConlrolUnitDescription Loop Control Detectors ESLCompatibility Style Unit lD# Per Circuit ldentifier 2820,Zone Model 7181 A B 10 S10A,S00 4720,Zone Model 7181 A B 10 S10A,S00 5104,Zone Mode17181 A B 10 S10A,S00 5107,Zone Mode17181 A B 10 S10A,S00 5204�12V) A 12C 12 S10A,S00 : 5204�12V) A 12C 15 S11A 5204124V� A 24C 15 S10A,S00 5204124V) A 24C 15 S11A 5207,Zone Mode17181 A B 10 S10A,S00 5207�12V) A 12D 15 S10A,S00 5207(24V) A 24D 20 S10A,S00 5207,Zone Model 5210 B 24A 10 S10A,S11A,S00 5208 w/5217 Zone Expander B,D 24F 40 S10A,S11A C6000 A 24EE 25 S09A,S10A,S11A,S00 C6000 B 24EE 25 S09A,S10A,S11A,S00 ' SK2224 B 24F 40 S09A,S10A,S11A,S00 SK4224 1CIeanMe B,D 24FF 30 S11A,S10A SK6324 B 24F 30 S10A,S11A Simplex-Grinnell(See TycoJ Spectronics Corporation Control Unit Description Loop Control Detectors ESL Compatibility Style Unit ID# Per Circuit Identifier 320 or 324 Zone Model 320/LC/OS-24 B Model# 12 S10A,S00 624/MX,Zone Model ADS or MX/OSRP B Model# 12 S10A,S00 624/MX,Zone Model MX/OSH or MX/10-10H B Model# 20 S10A,S11A,S00 624/MX,Zone Model MX/10-10 B,D Model# 10 S10A,S11A,S00 640 or 641,Zone Madel MX8/WIB,OSS,S2 B Model# 12 S10A,S00 640 or 641,Zone Madel S2A D Model# 12 StOA,S11A, 640 or 641,Zone Model MX8/WIBH or S2W B Model# 20 S10A,S00 640 ar 641,Zone Madel S2WA D Model# 20 S10A,St 1A,S00 FASA,Zone Model FASA B,D Model# 20 S10A,S11A,S00 GE Security ESL Compatibility Index-10/04 subject to change wiihout notice Call FaxBack for latest lisiings 800-483-2495 18 . Thorn Automated Systems Control Unit Description Loop Control Detectors ESL Compatibility Style Unit ID A� Per Circuit Identifier FIREQUEST 100-12 B 10112A 7 S10A,S00 FIAEQUEST 100-24 B,D 10124A 30 S10A,S00 FIREQUEST 200,Zone Model 2ZX B,D 200A 22 S10A,S11A,S00 FIREQUEST 200,Zone Model 4ZX,4ZXD B 200A 22 S10A,S11A,S00 or COMM CONT REV.W FIREQUEST 200,Zone Model U B,D 200X 22 S10A,S11A,S00 FIREQUEST 200,Zone Model MASTER HALON B,D 200A 22 S10A,S11 A,S00 FIREQUEST 200,Zone Model VSD B,D 200A 30 S10A,S11A,S00 FIREQUEST 300 B,D F2 20 S10A,S11A,S09A K-101-24 B,D 10124A 30 S10A,S11A,S00 KDA-1000,Zone Model AIZ or AIZ-2 D 1000A 30 S10A,S11A,S00 KDR-1000,Zone Model BIZ,BIZ-2,BIZ-5 B 1000A 30 S10A,S11A,S00 KDR-1000,Zone Model DZM B 1000B 30 S10A,S11A,S00 KDR-1000,Zone Model MIZP B 1000C 30 S10A,S11A,S00 ryCO Control Unit Description Loop Control Detectors ESL Compatibility Style Unit ID# Per Circuit Identifier Simplex 2001-8001,Zone Model 2001-1017 or B Model# 15 S10A 2001-1019 Simplex 2001-8001,Zone Model 2001-1018 or D Model# 15 S10A 2001-1020 or 2001-1027 Simplex 2001-8005,Zone Model 2001-1017 or B Madel# 15 S10A 2001-1019 Simplex 2001-8005,Zone Model 2001-1020 or D Model# 15 S10A 2001-1027 Simplex 2120,Zone Models 2120-0523,2120-0535, B Model# 30 S10A,S11A, ' 2120-7011 with 2120-0117 2120-7012 with 2120-0117,2120-7013 with 2120-0117 2120-7014 with 2120-0117,2120-7015 with 2120-0117 2120-7019 with 2120-0117,2120-7022 with 2120-0117 2120-7023 with 2120-0117,2120-7024 with 2120-0117 Simplex 2120,Zone Models 2120-7031 with D Model# 30 S10A,S11A, 2120-0117 2120-7032 with 2120-0117 Simplex 2120,Zone Models 2120-7031 with D Model# 30 S10A,S11A, 2120-7033 with 2120-0117 Zone Models,2120-7806,2190-9144, 2190-9145,2190-9153,2190-9154 Simplex 4001-9403,Zone Model 4001-9403 or B,D Model# 15 StOA Simplex 4001-9403,Zone Model 4001-9813 Simplex 4001-9404,Zone Model 4001-9404 or B,D Model# 30 S10A,S11A, Simplex 4001-9813,Zone Model 4001-9813 Simplex 4002,Zone Model 4002-5001, B,D Model# 15 S10A 4002-5002 or4002-7001 Simplex 4002,Zone Model 4002-5003, B,D Model# 15 S10A 4002-5004 or 4002-7002 Simplex 4100,Zone Model 4100-5001, B,D Model# 30 S10A,S11A, 4100-5002,4100-7001 or4100-7002 Simplex 4100,Zone Model 4100-5011,4100-5012, B,D Model# 30 S10A,S11A, 4100-7011 Wormald Autopulse 1000 B SZBt 50 S10A,S11A GESecurity ESL Compafibility Index-10/04 subject to change without notice Cal/FaxBack for latesf listings 800-483-2495 19 . TyCO (ContinuedJ Control Unit Description Loop Contro/ Detectors ESL Compatibility Style Unit ID# Per Circuit ldentifier Wormald Autopulse 2000 B M661 50 S10A,S11A,S00 Wormald Autopulse 2000 D M6D1 50 S10A,S11A,S00 Wormald Autopulse 3000 B M681 50 S10A,S11A,S00 Wormald Autopulse 3000 D M6D1 50 S10A,S11A,S00 Wormald Autopulse 4000 B M2061 50 S10A,S11A,S00 Wormald Autopulse 4000 D M20D1 50 S10A,S11A,S00 Multizone 6P B M661 50 S10A,S11A,S00 Multizone 6P D M6D1 50 S10A,S11A,S00 Multizone 20M B M20B1 50 S10A,S11A,S00 Multizone 20M D M20D1 50 S10A,S11A,S00 Multizone 20P B M20B1 50 S10A,S11A,S00 Multizone 20P D M20D1 50 S10A,S11A,S00 Walter Kidde Control Unit Description Loop Contro/ Detectors ESL Compatibility Style Unit ID# Per Circuit Identifier 295100,Zone Model MIZP B,D 10124A 30 S10A,S1 tA,S00 295101,Zone Model MIZP B,D 10124A 30 S10A,St tA,S00 Westec Conhol Unit Description Loop Control Detectors ESL Compatibility Style Unit ID# Per Ciicuit ldentifier MS-5000 Zone Model with or w/o MS5041/MS5042 A W 10 S10A,S11A,S00 Wormald US, Inc. (See TycoJ GESecurity ESL Compatibility Index-10/04 subject to change wiihoui notice Call faxBack for latest listings 800-483-2495 20 � � � � — ...... �:��;,.,,;:; �,.,,. ESL 500N Series Low-profile two-and four-wire photoelectric smoke detectors Overview The ESL 500N series two-and four-wire conventional photoelectric smoke detectors bring together trusted technology and a full line of features to meet the demands of every type of application.The 500N offers sounder models in two-and four-wire applications,specifically / to meet residential code requirements.The 521 NCSXT has the additional benefit of low current draw which makes it compatible with a wide variety of control panels.The ESL 500N series also offers ��� ¢ ; � choices for optional auxiliary relays and isolated heat sensors,not � 4 � available before in the ESL 500 series. � �f ESL offers CleanMeO,dust compensation,field replaceable optical chambers,multiple criteria heat algorithms,and self-diagnostics features. Outstanding Features The ESL 500N series detectors work on the light-scattering principle. A pulsed infrared light-emitting diode serves as the light source,and a high-speed photo diode as the sensing element.This design has Standard Features superior protection agains false/nuisance alarms caused by dust, insects,AF,and ambient light.The proprietary optical chamber is field replaceable. ° Built-in sounder available in two-and four-wire models • Patented CleanMe�feature A confirmed alarm causes the LED to light continuously.The unit • Built-in dust compensation indicates trouble by flashing the LED every second.This meets the • Field-replaceable optical chamber NFPA 72 field sensitivity testing requirements.Units with built-in 85dBa sounders emit a temporal 3 pattern when in alarm and will emit a steady tone when ihe input power is reversed. All wiring terminates in clamp-type screw terminals.The detectors mount to a standard single-gang electrical box,a 4-inch octagonal box,a 4-inch square electrical box,or WIREMOLD No.5739 fixture box. i � Speciticar�ons E/echica/ Environmental •Power supply,6/12 V operation:6.0 to 20 VDC polarity sensitive •Operating temperature,thermal models:32 to 100°f�0 to 37°C) •Power supply,12/24 V operation:8.5 to 33 VDC polarity sensitive •Operating temperature,nonthermal models:32 to 120°F�0 to 50°C) •Maximum ripple p-p 16/12/24 V�:10%(V p-p) •Storage temperature:-4 to 158°F�-20 to 70°C) •Typical average standby current:70 uA ✓` ✓ Operating humidity range:0 to 95%noncondensing .Typical alarm current(6/12/24 V►:up to 60 mA max.if not limited by Physical control panel •Detector head dimensions:5.5 in.(140 mm►dia.;2 in.�50 mm)high •Auxiliary relay contacts:1.0 A C�?30 VDC;Form C •Mounting dimensions:5.25 in.(133 mm)dia.;0.3 in.(8 mm)high •Alarm contacts:500 mA C�?36 VDC(resistive) •Weight:9.6 oz.(272 g) Features •Construction:ABS plastic •RFI immunity:20 V/m min.;1 to 1000 MHz Color:White head and base •Field wiring size:12 to 24 AWG;16 to 22 recommended Packaging:10 detectors per carton ,Heat detector,rate of rise:15°F/min(8.3°C/min)and>105°F Regulatory (40.6°C) •UL,CUL,CSfM •Heat detector,fixed threshold:135°F(57.2°C) •UL 2-wire compatibility identifiers:S10A,S11 A •Drift compensation adjustment:1.0%ft.max. •Reset time:1 sec.min. •Photoelectric sensitivity:3.1%+0.5 to 1.0% Related Diagram Ordeiing Infom►ation 521 NCRXT 2-wire,CleanMe,heat sensor,aux.relay,8.5 to 33 VDC, S11A 521 NCSXT 2-wire,CleanMe,heat sensor,sounder,8.5 to 33 VDC, S10A 521 NCSRXT 2-wire,CleanMe,heat sensor,sounder,aux.relay,8.5 to 33 VDC,S11A � --� � �-- , �. 541 NB 4-wire,6 to 33 VDC � E JI I 1 1 1 I I� ,� N o� `r 541 NBXT 4-wire,heat sensor,6 to 33 VDC v � �� / / ; 541 NCSRXT 4-wire,heat sensor,sounder,aux.relay,8.5 to 33 VDC � --_ 541NCSXTE 4-wire,heat sensor,sounder,end of line relay,8.5 to 33 VDC 541 NCSRH 4-wire,isolated heat sensor,sounder,aux.relay,8.5 to 33 VDC 541 NCRXT 4-wire,heat sensor,aux.relay,8.5 to 33 VDC 541 NCXTE 4-wire,heat sensor,end of line relay,8.5 to 33 VDC 541 NCSXT Photoelectric 4-wire smoke detector,sounder,8.5 to 33 VDC ��� 503-665-5700 Asia Europe �S[,(�,� GESgCp�/fi/ 888-G6SECURITY te1652-2907-8108 te1+44-113-238-1668 � (437-3287) fax 652-2142-5063 fax+44-113-253-8121 faxback 800-483-2495 Australia Latin America emailinfoQgesecuriry.com te1+61-3-9259-4700 te1305-267-4301 www.GESecurity.com www_gesecurity.com fax+613-9259-4799 fax305-267-4300 As a comparry of innovation,GE Securiry reserves[he right m change pmduct specifications wiMout notice.Por the latest pmduct specifications,visit GE Securiry online at www.GESeariry.com or contaci your GE Security sales representative. IPS-ESL 500N Series-2005-04-27 03:55:47 Neleased:D.042005 � , ESL 500 Series Note Please refer to the ESL Compatibility Index for a complete S m o ke Detecto r 1�sting of p trol panels and proper identifiers.For a copy of the Com atibili Index,call 1-800-648-7424 or visit www.sentrol.com for a copy to down load.Remember, Installation Instructions 4-wire smoke detectors do not require a comparibility listing. Description A WARNING This document is intended for licensed electricians/ The ESL 500 Series Smoke Detectors offer 2-wire,4-wire,12VDC, alarm installers.Interlogix csnnot provide technical and 24VDC detectors for fire system applications. support to unqualified persons. Depending on the model,the smoke detector pmvides the following features: If you have questions,call Interlogix st 1-800-648-7424. Detector/base lock Discourages unauthorized removal of the smoke detector by requiring Selecting a Location a screwdriver to remove the detector from the base. Selecting a suitable location is critical to the operarion of smoke C1eanMe� detectors.T'his equipment should be installed in accordance with Enables the control panel to receive a waming signal via a 505 the National Fire Protection Association's(NFPA)Standard 72. module,or C1eanMe compatible panel,indicating that the optical A-8-1.2.1.a Where to Locate the Required Smoke Detectors in chamber needs to be replaced.This feature is available on the 521/ Existing Consnuction.The major threat from fire in a family 528 Series 2-wire detecto�only. living unit occurs at night when everyone is asleep.The The detecto�ship with the C1eanMe feature tumed off.To tum on principal threat to persons in sleeping areas comes from fires in the CleanMe signal move DIP switch 2 on the back of the detector to �e remainder of the unit.Therefore,a smoke detector(s)is best the"on"position.See Figure 1. located between the bedroom areas and the rest of the unit.In units with only one bedmom area on one floor,the smoke o" l /��\ detector(s)should be located as shown in Figure 2 A. 1.On=A(6-12V)range � G /.-'��� ' In family living units with more than one bedroom area or with : Off=C(12-24V)range � �'�� bedrooms on more than one floor,more than one smoke detector � z.o�=CleanMe signal on i is required,as shown in Figure 2 B. OR=CIeanMe signal ofl I �i . (521/528 Saries only) �\ I �o o� Note � NO COM NC / ' Tuming the CleanMe signal � � on witlaut usfng fhe 505 � module and/or compatible �� penel will aeete a trouble Relay(CRXT)unit only Dining Kipy�en gedrop� Bedrop� . � signal. R� � � Correct Incorrect 2 A � • Figure 1.Switches u��R� �,�,,, � Self�tiagnostics Includes automatic sensirivity testing.Once a day and immediately upon first power up,each 500 Series detector performs a full N� a� �' �°`°°m diagnostic test that includes a dynamic test of the sensing chamber � ' and internal electronics.This meets NFPA 72 field sensitivity testing Z e � requirements without the need for external meters. `"'"B`�°°"' �°'°°'" • � Drift compensstion The detectors automatically adjust sensitivity,up to a ma�cimum of eaa�m 1.0%/ft.,as the detectors become dirty. � Using the 2-wire 521/528 Series with a panel that does not have 2- wire capabilities : The ESL 505 module can convert the 2-wire 521/528 Series to a 4- wire input on the control panel.The 521/528 Series is UL Listed as compatible with the 505 module and will be fully UL compliant with � • �� any UL listed 24 VDC control panel and panels that do not operate 2 c ��� '�� below 12V.Each 505 module will accommodate up to 20 ESL 521/ • 528 Series smoke detectors.See the 505 module installation a�"m° i °ia"� instructions for more information. ! Selectable voltage range for UL 2-wire compa6bility ea��c ' 1'he 500 Series 2-wire smoke detectors have a DIP switch that allows the installer to choose between 12/24V operation and 6/12V �=Required srtake deteGors operation.See Figure 1 and Specifications. �_�d�ba,ai s�ace deieao�s�y��red r���co�sw�o� Figure 2.Detector placement ESL 500 Series 1 In addition to smoke detectors outside of the sleeping areas,the Installing the Detector installation of a smoke detector on each additional story of the family All wiring must conform to the Narional Electric Code(NEC) living unit,including the basement,is required.These installations and/or local codes having jurisdiction.Use 12 to 24 AWG wire are shown in Figure 2 C.The living area smoke detector should be to install the detector. installed in the living room or near the stairway to the upper level,or in both locations.The basement smoke detector should be installed in 1. If you are using the detectodbase lock,remove the detector close proximity to the stairway leading to the floor above.Where ��kout and break off the tab on the mounting base.See installed on an open-joisted ceiling,the detector should be placed on the bottom of the joists.T'he detector should be positioned relative to Figure 3. the stairway to intercept smoke coming from a fire in the basement 2• Remove the red plastic cover from the detector.The before the smoke enters the stairway. detector is shipped with a cover for protection against construction site dust. A-B-I.Z.I.b Where to Locate the Required Smoke Detectors in New Construction.All of the smoke detectors specified in A-8-1.2.1.a for 3. Run system wiring to the detector location and mount existing construction are requued and,in addition,a smoke detector electrical boxes if necessary. is required in each bedroom. 4. Line up and attach the gasket(if the detector comes with a gasket)and mounting base to the electrical box,wall or A-S-1.2.1.c Are More Smoke Detectors Desirable? ceiling using the screws provided.Use the wall anchors if The required number of smoke detectors might not provide reliable necessary.See Figure 5. eady warning protection for those areas separated by a door from the 5. Strip the system wires and connect them to the appropriate areas protected by the required smoke detectors.For this reason,it is recommended that the householder consider the use of additional ���nals on the detector.See Figure 6. smoke detectors for those areas for increased protection.The 6. Attach the detector to the mounting base as follows: additional areas include the basement,bedrooms,dining room, -Line up the raised tab on the side of the detector with the furnace room,utility room,and hallways not protected by the arrow on the mounting base.See Figure 4. required smoke detectors.The installation of smoke detectors in -Insert the smoke detector into the base and turn kitchens,attics(finished or unfinished),or garages is not normally clockwise approximately 15 degrees.It should snap recommended,as these locations occasionally experience conditions firmly into place. that can result in improper operation '7. Apply power. Important:Regulations pertaining to smoke detector installations g• Test the detector.See Smoke Testing the Alarm. vary from state to state.For more information,contact your local fire departrnent or local authority having jurisdiction. In addition to NFPA 72,use the following location guidelines to optimize performance and reduce the chance of false alarms from the , detector: � � ��� ����� ���^� • Locate ceiling-mounted smoke detectors in the center of a room ' � ?� or hallway at least 4 inches(lOcm)from any walls or partitions. � • Locate wall-mounted smoke detectors so the top of the detector is 4 to 12 inches(10 to 30cm)below the ceiling. ,���1� �' �,`� • Do not locate detectors in or near bathrooms or kitchens. � � � • Locate in a suitable environment as follows: -Temperature between 32°F(0°C)and 100°F(37°C) -Humidity between 0 and 95%non�ondensing Figure 4.Mounting • Locate away from air conditioners,heating registers,and any other ventilation source that may interfere with smoke entering the detector. • Mount smoke detectors on a firm permanent surface. Smoke Testing the Detector Smoke detectors should be tested in place annually using smoke ♦ or canned aerosol simulated smoke. Follow the instructions on �_�� the canned smoke or use the following steps to test the detector '������-, with smoke: �������` I r ��'���� � * 1. Hold a smoldering punk oc cotton wick close to the smoke entry openings. ' 2. Gently direct the smoke into the detector for 20 seconds or �_�_� untii an alarm is indicated. �—� ` Be sure to extinguish the smoke source after testing! The --" detector LED should stay on and an alazm should be indicated at Figure 3.DetectoNbase lock the control panel. Use the system reset switch to reset the detector. 2 ESL 500 Series Models without gaskets: Models with gaskets: 511 C,511 AFT,518C,518AFT,521 B, 521 CRXT,528CRXT,541 C,541 CXT, 521 BXT,528B.5286XT 541 AXT,548C,548CXT,548 AXT � � �.� � >� � - � � � x � '9' � ������i �' ,����'�'��,'-. � `1 � �' �`'.�. � ; � �� �� � �� ��, �� �� � � ry f � : \ �� I'/ syny �/ . /// � - /�� � � / � �F..`� � � :/ ��� /, � �//, � Figure 5.Detector installation 511/518/521/528 Series 2-wir+e wiring diagram 2-wire O EOL . initiating + Device CIlCUIf — O . � Listed Alartn Control O O �O O — + _ �. Note:The 521/528 Series are polarity sensitive. Model 511G518C Model 521CRXT/528CRXT 511AFT/518AFT � Note:The 511/518 Senes are not CleanMe First Last � compatible. Detector 5218/5288 pet�a � 521 BXT/5288XT � p O - AWaming:The system may not operate if the � detector is not connected to the control unit - initia6ng device dreuit as spedfied in the . detector a control unit IiteraW2. 541/548 Series 4wire wiring diagram ESL 2D4-12l24V �. Power Power + Supervision . _ O O O O Relay — f- — + Listed PJarm Conirol Model 541 C/548C 541AXT.548AXT Mode1541CXT/548CXT Note:The 541/548 Series are not First Last � CleanMe compatible Detector O Detec[w O O❑ .. Initiating O � Circuit O EOL Resistor � Figure 6.Wiring diagrams Understanding the LED Removing the Detector The LED on the detector indicates the status of the detector as To remove the detector from the mounting base,grasp the : follows: detector and turn it counterclockwise appro�cimately 15 degrees. F7ashing every 9 seconds=Normal operation. The detector should snap off of the mounting base. On=Detects smoke,sending an alarm. Off or flashing once every 1.5 seconds=Trouble or maintenance To remove the detector from t6e mounNng base when the is required.Test the detectoc See Testing the Detector Sensitivity. detectodbase lock is used,insert a small screwdriver into the locking tab slot on the side of the base and press in while simulta- neously turning the detector counterclockwise I S degrees. See Figure 8. ESL 500 Series g Testing the Detector Sensitivity The detector provides a sensitivity test that allows you to check the ' detector sensitivity using a test magnet and the LED indicator on the j�� \ detector as follows: � �� � 1. Hold the test ma et u to the raised TEST letters on the to of % V`� � p p p the detector for 2 seconds. See Figure 7. Once the test starts, I � \ / the alarm LED flashes one to nine times. �> � 2. Count the number of times the LED flashes and use the following table to determine the status of the detector sensitivity Figure 7.Testing the detector and what action to take,if any. Flashes Obscuration Indication Action (Approx) 1 NIA Unserviceable Reset unit and rerun hardware fault sensitivity test.If the error detected. persists,replace the unit. 2-3 N/A Detector is not Clean the unit.Reset unit sensitive enough. and rerun sensitivity test. — If the error persists, replace the unit. � 4 3.6%/ft Detector is within N/A 5 3.1%/ft normal sensitivity range. j/,l_� 6 2.6%/ft �' 7 2.1°/a/fl � �� 8-9 N/A Detector is too Verify that the smoke � sensitive. chamber is snapped -- down securely.Clean unit. After the test: Figure 8. Unlocking the detector If the sensitivity is within timits and all other tests pass,the detector goes into alarm and must be reset from the control panel. If the sensitivity is not within limits or an unserviceable hardware fault has been detected,the detector LED flashes every 1.5 seconds until the detector is serviced. t, � Cleaning the Detector � ;�__L Clean the detector cover with a dry or damp(water)cloth as needed F to keep it free from dust and dirt. f / � When necessary,clean the detector interior and replace the optical �__ chamber as follows: 1. Disconnect the alarm notification appliances,service release devices and extinguishing systems. Figure 9.Removing the detector cap 2. Slide a flat-blade screwdriver into the slot on the detector cap and gently push the handle down to pry the cap up and off. See Figure 9. 3. Press in on the sides of the optical chamber and pull it up and away from the detector and discard. See Figure 10. 4. Use a vacuum to remove dust and diR from the optical chambe� base. 5. Line the new optical chamber up with the optical chamber base and snap it down into place. oPUCai cr,amne� 6. Replace the detector cap as follows: -Line the tabs on the cap with the slots on the detector. -Insert the cap into the smoke detector and turn clockwise Optical chamber base approximately 15 degrees. It should snap firmly into place. 7. Test the detector sensitivity(See Testing the Detector Sensitiviry). �it�T 1 8. Reconnect all alarm notification appliances,service j` �— Detector cap release devices and extinguishing systems. Important:The control panel alarm and all aiixiliary functions should be verified for a complete test of the system. Figure 10.Removing the optical chamber 4 ESL 500 Series Maintaining the Detector Limited Warranty These smoke deteCtors are designed for easy field Service and ESL is a brand name of Interlogix,Inc.The manufacturer wacrants this maintenance. When installed and used properly,they require smoke alarm to be&ee from defects in material and workmanship under minimal maintenance. conditions of normal use for a term of 3 years from the date of mauufacture. During the wartanty period,if an Interlogi�c product or any of its compo- The smoke detector should be tested monthly. See Testing the nents becomes defective,it will be repaired or replaced without chazge. Detector Sensitivity and Smoke Testing the Detector. Out-0f-warranty units will be repaired at the discretion of the manufacturer, if not,a card will be forwarded to the customer suggesting a replacement Fire Prevention and Esca @ unit and che cosc of that unit. P This warranty does not apply to units which have been subject to abuse, The pwpose of an early warning smoke detector is to detect the presence of misuse,negligence or accident,or to which any modifications,alterations fire in its early stages and sound an alarm giving the cecupants time to exit oc repairs have been made or attempted. the premises safely. This warranty is extended only to the original purchaser of the smoke alaRn and may be enforced only by such person.During the warranty period,if Avoid Fire Hazards the alarm or any warranted components thereof becomes defecrive,at the No detection device can procect life in all situations.Therefore,safeguards manufacturer's discretion,it will be replaced or repaired without chazge if should be taken to avoid potentially dangerous situations as follows: retumed in accordance with the following inshuctions: • Do not smoke in bed. Obtain a Retum Authorization Nutnber by calling 1-800-648-7422 or 503- • Do oot leave c6ildren home alone. 692-4052,then carefully pack it in a well padded and insulated carton and • Never clean with flammable liquids such as gasoline. retum,postal charges prepaid to: • Properly sWre materials.Use general good housekeeping techniques to Customer Service ; keep your home neat and tidy. A cluttered basement,attic,or ofher Interlogix,Inc. storage area is an open invitation to fire. 12345 SW Leveton Drive '15�alatin,OR 97062-9938 • Use combustible materials and electrical appliances carefully and only A note should be included advising the nature of fhe malfunction.Caze for their intended uses.Do not overload electricaloutlets. must be exercised in the ro r kin of alamis retumed under fhis P Pe P� B • Do not store explosive and/or fast burning materials in your home. W,�ty as Interlogix will not be responsible for warranty repairs to • Even after proper precautions ttave been taken,fires can start. equipment damaged because of improper packing. �p�Pa�, T6e above warranty is in lieu of all other eapress warranties,aod impGed warrantles of inerchantability and fitness for a particular purpose are timited in duration for a period of 3 years from the date of In Case of Fire manufacture.Under oo circumstances shall manufacturer be liable to In the event of a fire,you should do the following: the purchaser or any other person for iucidental or wnsequential • Leave immediately.Dodt stop to pack or search for valuables. damages of any nature,including without limitation damages for • In heavy smoke,hold your breath and stay low,crawl if necessary.The personal injury or damages to property,and however occasiooed, clearest air is usually near the floor. whether alleged as resulting from breac6 of warranty by maaufac- • If you have to go through a closed door,carefully feel the door and door ��y the negligence of manufacturer or otherwise.Manufacturer's knob to see if undue heat is present. If they seem cool,brace your foot �ability will in oo event eaceed the purc6ase price of the produc�Some against the bottom of the door with your hip against the door and one states do not allow IimitaHons on how long an implied warranty Iasts, hand against the top edge.Open it slightly.If a rush of hot air is felt, or the eaclusion or limitatiou of incidental or consequenHal damages, slam the door quickly and latch it. Unvented fire tends to build up �the above limitations and exclusions may not apply to you.Unless a considerable pressure.Be sure all membeis of the household realize and �ooger period is required by applicable law,any acHon against understands this dangec manufacturer in connection with this smoke slarm must be commenced • Use your neighbor's phone or a street fire alarm box to call the fire �thin one year after the cause of acHon has occurred. deparfinent.The job of extinguishing the fire should be left to the No agent,employee or representative of the Manufacturer nor any other professionals. person is authorized to modify this warranty in any respect.Repair or replacement as stated above is the exclusive remedy of the purchase hereunder.This warranty gives you specific legal rights and you also have Be Prepared other rights which vary from state to state. Practice the following steps to prepaze you and your family in the event of a fire: WARNING • Perform fire drills regularly.Use them to asswe recognition of an alazm Limitations of smoke detectors signal. Smoke detectors aze very reliable,but may not work under all condirions. • D�aw a floor plan and show two exits&om each room.It is important No smoke detector provides total protection of life or property.Smoke that children be instructed carefully,because they tend to hide in times detectors are not a substitute for life insurance. of crisis. Smoke detectors require a source of power to work. • Establish one meering place outside the home.Insist that everyone meet This smoke detector will not operate and the alarm will not sound if the there during an alum.This will eliminate the tragedy of someone detector is not installed properly. reentering ihe house for a missing member who is actually safe. Smoke detectors may not be 6eard. A sound sleeper or someone who has • If you have children and/or physically challenged people residing in �ken drugs or alcohol may not awaken if the detector is installed outside a yow household,use window decals to help emergency personnel ��m.Closed or partially closed doors and distance can block sound. identify the sleeping quarters of these individuals. This detector is not designed for the hearing impaired. Smoke detectors may not always activate and provide waming early enough.Smoke detectors only activate when enough smoke reaches the AWARNING detector.If a fire starts in a chimney,wall,roof,on the other side of closed : Smoke detectors CANNOT provide warnings for fires resulting doors,or on a different level of the property enough smoke may not reach from eaplosions,smoking in bed or other fumiture,ignitioo of �e detector for it to alarm. flammable tiquids,vapors and gases,children playing with Smoke detectors are a significant help in reducing loss,iajury and even : matches or lig6ters. death.However,no matter how good a detection device is,nothing works perFectly under every circumstance and we must wam you that . Failure to properly install,test,and maintain a smoke detector you cannot eapect a smoke detector to ensure that you will never suffer system may cause it to fail resulHng in loss of life and/or aoY damsge or injury. PraPerty• ESL 500 Series 5 , .. , , Specifications Voltage DIP switch 1 ON for standard 12V operation(6.5-20 VDC),polarity sensitive ' DIP switch 1 OF'F for standard 24V operation(8.5-33 VDC),polarity sensitive Ma�cimum ripple(pk to pk) 10%(V p-p) Typical average standby current 70 uA(12/24V) : Typical alarm current(12/24V) up to 60mA max.if not limited by control panel Awc.relay contacts 2A @ 30VDC Alarm contacts SOOmA @ 36VDC(resistive) Photoelectic sensirivity 3.1%+0.5- 1.0% Operating termperature 32°to 100°F(0°to 37°C) Operating humidity range 0 to 95%non-condensing RFI immunity 20V/m minimum;0-1000MHz Color white head and base Field wiring size 12-24 AWG Detector packaging 10 detectors per carton Heat detector specifications rate of rise- 15 F/min and>105 F(83 C/min and>40.6 C) UL 2-wire compatibility identifier: 521/528-DIP switch 1 ON S09A 521/528-DIP switch] OFF S10A,S11A(RX models) 511/518 S10A Drift compensation adjustment 1.0%/ft.max Detector head dimensions 5 in.(12.7cm)diameter;2 in.(Scm)height Mounting dimensions 4.75 in.(121 cm)diameter,0.3 in.(O.8cm)height Reset time I second minimum Listings: 511/521/541 UL 268 518/528/548 ULC Product Ordering Model Description 511 C/518C 2-wire,photcelectric,6.5-33 VDC S11AFT/518AFT 2-wire,photoelectric,6.5-33VDC,rate of rise heat sensor 521B/528B 2-wire,photoelectric,6.5-33VDC 521BXT/528BXT 2-wire,photoelectric,8.5-33VDC,multi-criteria algorithms,fixed/rate of rise heat 521CRXT/528CRXT 2-wire,photcelectric,8.5-33VDC,awc.relay,multi-criteria al orithms,fixed/rate of rise heat 541G548C 4-wire,photcelectric,8.5-33VDC 541CXT/548CXT 4-wire,photoelectric,8.5-33VDC,multi-criteria algorithms,fixed/rate of rise heat 541AXT/548AXT 4-wire,photcelectric,6-20VDC,multi-criteria algorithms,fixed/rate of rise heat Accessories: 505 Module that interprets the 521/528 models C1eanMe signal for panel and can conveR 2-wire 521models to 4-wire inputs on the paneL 401 Test magnet in plastic shell for pole mounting SM-200 Smoke!in a can�(canned smoke)for functional testing of smoke detectors 211 Replacement optical chambers(set of 10)