Loading...
HomeMy WebLinkAbout0089948-Plumbing � CITY OF OSHKOSH No 89948 OSHKOSH PLUMBING PERMIT -APPLICATION AND RECORD ON THE WATER Job Address 117 W NEVADA AVE Owner CHERYL A WINTER Create Date 10/02/2001 Contractor RASMUSSEN PLUMBING Category 410-Residential-Interior Plan Bathtub 1 Shower 0 Ejector/Grind Dip Well F Prep Sink Gar Drain Whiripool Floor Drain Water Softner Drink Ftn Serv Sink Soda Disp Lavatory 1 Lndry Tray Local Waste Wait.St. Shamp Sink Coffee Maker Toilet 1 Lndry Stndp Clothes Wshr Ice Chest Flr/Wst Sink Int Grease Trap Res.Sink Disposal Bidet Exam Sink Catch Basin Ext Grease Trap ' Bar Sink Dishwasher Beer Tap Sculry Sink Wash Ftn Water Heater Sump Pump Dent.Oper. Hand Sink Urinal Site Drain Classrm Sink Lab Sink Plaster Sink Standp Rec Roof Drain Breakrm Sink Sterilizer Surgeons Sink Ice Maker Use/Nature FR/Replace tub,shower,lav and toilet. of Work Size Material Type # Conn.Type Sanitary Sewer Storm Sewer Water Service Valuation $3,000.00 Plan Approval $0.00 Permit Fees $20.00 Issued By �W� Date 10/02/2001 � Permit Voided I In the performance of this work, I agree to perform all work pursuant to rules governing the described construction. Signature Date AgenUOwner Address 1914 GREENBRIAR TRL OSHKOSH WI 54904 -8887 Telephone Number 920-233-6747 WATER DISTRIBUTION DATASHEET � ' Date:October 3,2001 Name: RASMUSSEN PLBG Project: 'REMODEL Street: Street: 117 W NEVADA AVE City: City: 1. 10.4 Gallon per minute buiding demand,predominatly Flush Tank. 2. 64.0 Low pressure at the Main in Street. 3. A Lb loss from a.0 ft difference in elevation from Main in Street to the Water Meter. 4a. 2.0 Lb loss from a 15.0 ft 3/4" Copper Tube Type K AST'M B88 water service from the Main in Street to the curb stop. Pressure loss detemined using a C value of 150,inside diameter of.745 and a velocity of 7.7 ft per sec. 4b. 5.5 Lb loss from a 40.0 ft 3/4" Copper Tube Type K ASTM B88 water service from the curb stop to the Water Meter. Pressure loss detemined using a C value of 150,inside diameter of.745 and a velocity of 7.7 ft per sec. 5. 4.1 Lb loss from a 5/8in Meter 6. 52.4 Lbs of pressure available at the Water Meter. This value is entered in(B)below. The(A)value listed below is determined by using the following formula,then rounding the result up. A_ B-(C+D+E) x 100 F A. 34 Pressure available for uniform loss(psi/100 feet of pipe). B. 52.4 Lbs of pressure available at the Water Meter. C. 20.0 Pressure needed at the controlling fixture.T/S FAUCET D. 7.4 Lb loss resuiting from a 17.0 ft difference in elevation from the Water Meter to the controlling fixture. E. .0 Lb pressure loss due to a WTR SFNR serving the controlling fixture. F. 75.0 Ft Developed length from the 50.0 ft actual length of piping from the Water Meter to the controlling fixture. Maximun Allowable load for Copper Tube Type M, ASTM B88 Nominal Size 1/2 5/8 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4 Actual I.D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935 Value of C 150 150 150 150 150 150 150 150 150 150 Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8 Maximum Gpm 6 0 12.5 21.5 32 45 79 121 174 303 Ma�cimum FM WSFU 0 0 4.5 7 17 39 144 374 731 1835 Maximum FT WSFU 7.5 0 18 34 62 112 270 484 776 1835 � Fixture Listing � " Date:October 3,2001 Name: RASMUSSEN PLBG Project: 'REMODEL Street: Street: 117 W NEVADA AVE City: City: Non Public Use Fixtures Hot Cold Total 1 Automatic Clothes Washer 1.00 1.00 1.50 1 Dishwashing Machine 1.00 .00 1.00 2 Hose Bib, 1/2"diameter .00 6.00 6.00 1 Kitchen Sink 1.00 1.00 1.50 I Bathtub,lavatory and water closet-FT group 2.00 3.50 4.00 Total Water Supply Fixture Units 5.00 11.50 14.00 10.4 Gailon per minute demand of the building.Predominatly Flush Tank 33.4 Pressure available for uniform loss.For the table use-34.0 Maximun Allowable load for Copper Tube Type M, ASTM B88 Nominal Size 1/2 5/8 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4 Actuai I.D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935 Value of C I50 150 150 150 150 150 150 150 150 150 Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8 Maximum Gpm 6 0 12.5 21.5 32 45 79 121 174 303 Ma�cimum FM WSFU 0 0 4.5 7 17 39 144 374 731 1835 Ma�cimum FT WSFU 7.5 0 18 34 62 I 12 270 484 776 1835 r �* Fixture Listing ° Date:September 26,2001 Name: �� ��$ �'v 5 5 f w �� �-Y�Gr . �� ^�T�'ti' �( Project• Street: / '�l �K �j.Qp.ti ���• .�4-� � Street: /I � � /�'e' `i q�� ���: h � �t�os � �s sy�o Y C�Ty: o s h��s�� Non Public Use Fiztures Hot Cold Total 1 Automatic Clothes Washer 1.00 1.00 1.50 I Dishwashing Machine 1.00 .00 1.00 2 Hose Bib, 1!2"diameter .00 6.00 6.00 1 Kitchen Sink 1.00 1.00 1.50 1 Bathtub,lavatory and water closet-FT group 2.00 3.50 4.00 Total Water Supply Fixture Units 5.00 11.50 14.00 10.4 Crallon per minute demand of the building.Predominatly Flush Tank 12.6 Pressure available for uniform loss.For the table use- 13.0 Maaimun Allowable load for Copper Tube Type M, ASTM B88 Nominal Size 1/2 5/8 3/4 1 1 1/4 1 1/2 2 2 I/2 3 4 Actual L D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935 Value of C 130 130 130 130 130 130 130 130 130 130 Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8 Maximum Gpm 4.5 0 11 21.5 32 45 79 121 174 303 Ma�cimum FM WSFLJ 0 0 4 7 16 38 144 369 731 1833 Matcimum FT WSFLJ 5 0 15 34 60 110 270 480 776 1833 • WATER DISTRIBUTION DATASHEET � Date:September 26,2001 Name: �� (`A"S W``.C..l s.`ti- V '�j �C, Project: W l ^--� r Street: 1� �y .,e2,,, �p P� �t� � Street: � �� � � �� V /�'�`� City: �� � �D� City: �.s��� ,Sn 1. 10.4 Gallon per minute buiding demand,predominatly Flush Tank. 2. 52.0 Low pressure at the Main in Street. F � 3. 1.3 Lb loss from a 3.0 ft difference in elevation from Main in Street to the Water Meter. 4a 2.7 Lb loss from a 15.0 ft 3/4° Copper Tube Type K ASTM B88 water service from the Main in Street to the cwb stop. Pressure loss detemined using a C value of 130,inside diameter of.745 and a velocity of 7.7 ft per sec. 4b. 7.1 Lb loss from a 40.0 ft 3/4" Copper Tube Type K ASTM B88 water service from the curb stop to the Water Meter. Pressure loss detemined using a C value of 130,inside diameter of J45 and a velocity of 7J ft per sec. 5. 4.1 Lb loss from a 5/8in Meter 6. 36.9 Lbs of presswe available at the Water Meter. This value is entered in(B)below. The(A)value listed below is determined by usi�g the foliowing formula,then rounding the result up. A— B C+D+E x 100 A. 13 Pressure available for uniform loss(psi/100 feet of pipe). B. 36.9 Lbs of pressure available at the Water Meter. C. 20.0 Pressure needed at the controlling fixture.pres bal D. 7.4 Lb loss resulting from a 17.0 ft difference in elevation from the Water Meter to the controlling fixture. E. .0 Lb pressure loss due to a serving the controlling fixture. F. 75.0 Ft Developed length from the 50.0 ft actual length of piping from the Water Meter to the controlling fixture. Maximun Allowable load for Copper Tube Type M, ASTM B88 Nominal Size 1/2 5/8 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4 Actual I.D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935 Value of C 130 130 130 l30 130 130 130 130 130 130 Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8 Marimum Gpm 4.5 0 11 21.5 32 45 79 121 174 303 Maacimum FM WSFU 0 0 4 7 16 38 144 369 731 1833 Maximum FT WSFU 5 0 15 34 60 110 270 480 776 1833