HomeMy WebLinkAboutInspection Report - 04/23/1979� �i%
� c��;����ci� r.�nN��.r�; ni�;.,,�.�� ; _, ������,.
�' April 23 , 1979
I '
1NSPECTION REPORT
Addr�•ss of Inspection : ll ''3 No . Sawyer Street , Oshkosh , Wi .
Date of inspection : Apri ] 19 , 1979
For : Russell Beck of Valr�'y Realty & Construction
By ; Merlin G. Raab Assist +�nt Building Inspector
Approximately 3/4 of the area under the house crawl--space -.
with the remainder being full basement . The crawl space has a dirt
floor approximately thre� feet below the floor system. The floor
syst��ms structural suppork members do not meet present code require-
mentr; , but do not appear to sag . The house is supported by a series of
ston�� piers . Floor joists are supported by a series of wood beams
spanning between piers . 'The floor joists are let-in to the beams
sidc� for support . Sever�� l floor joists framing into the north exterior
wall beam have separated or are about to separate from the beam .
Corrective measures should be taken to support floor joists in this :
and any other areas wherr this has occurred .
Other than serveral windows ( Closed at time of inspection) I
found no measns of ventilating the crawl area . I recommend that
several screened and louvered vents be installed .
� Merlin G. Raab
Assist.ant Building Inspector
• P. O. BOX 1130 • OSHKOSH, WISCONSIN 54901