Loading...
HomeMy WebLinkAboutMinimum Housing, Building/Property Maintenance - 07/29/1992 s , . � CODE ENFORCEMENT DIVISION � Department of Community Development City of Oshkosh o.�KO.� �I OLAT I ON C�R I ON THE WATER / RECT I ON NaT CE � Date Inspected JULY 29, 1� OCCUPANCY INSPECTED TW'0 FA�IILY DWEl1ING BEING USm AS ROOMING HOUSE ADDRESS IO� W ST �fH AV NUE OWNERS h'EiME ADDRESS NORTH MAIN STREET NOTICE DELIVERED/EXPLAINED TO MAILED FOLLOWING COMPLAINTS cc • ITEM # ORDER FINDINGS OF INSPECTION 1 . 16-35A ( 6 ) SAFE AND CLEAN DWELLING UNITS AND PREMISES. NO OWNER SHALL RENT TO ANY OTHER PERSON FOR OCCUPANCY OR ALLOW ANY PERSON TO OCCUPY ANY DWELLING UNIT UNLESS IT IS SAFE AND CLEAN, AND COMPLIES WITH ALL PROVISIONS OF THE MINIMUM HOUSING CODE AND PROPERTY MAINTENANCE CODE. ?: .1�-39 �P) THE L'6^IE!!ING IS ��Il�JG �S� �,`S ,^, R�M��:G '�JS� E•�ITri �e�E �IRSi r�� �F(`:��� � I.�-4O �C) FLOOR LIVING UNITS HAVING READY ACCESS' TO EACH OTHER� THE SECO!`� FlAOR � ' TENANTS HAVE ACGESS TO THE FIRST FLAOR LAUNDRY kJHICH IS IN THE LIVING UNIT Alm NOT A COMMON SPACE� BOTH SECOND FLAOR AND FIRST FLOOR TENAM'S HAVE READY ACCESS TO KITCHEI�! FACILITIES AND BATHROOM FACILITIES ON EACH FLOOR� THE ROOMING MOUSE USE SMALL� CEASE� THE TV�D DWELLING UNITS SHALL BE SEPARATED FROM EACH-0THER PER ZOfJ�NG ORDINANCE DEFINITION OF A TWO FAMILY DµJELLING� A PERMIT WILL BE P,EQUIRED� - 3, 18-79�� THE GARAGE ON THE PREMISES IS DE�'ERLORATED Alm SHALL BE SCRAPED, PRIMED = AND PAINTED AI� ALL DAMAGE TO THE DCTF�2IOR SIDING A(�D DOORS PROPERLY REPAIRED� SECOND FLOOR LIVING UNIT, �FOUR ROOMS RENTED IfmIVIDUALLY) 4� 16-33 (6) CODE COMPLIANT GUARDRAILS ARE REQUIRED ON THE ROOF AREA OUTSIDE THE SECOfm EXIT DOOR� PERMIT REQUIRm� 5, 16--� ��i) A DECK SHALL BE INSTALLED ON THE ROOF AREA AS THE STEP FROM THE LIVING UNIT IS MORE THAN EIGHT INCHES IN HEIGHT Afm FOR PURPOSES OF LOADIIVG ON ` THE ROOF� PERMIT REQUIRED� 6, 18-79�.1B THE UPHOLSTERED SOFA SHALL BE REMOVED FROM THE REAR ROOF AREA� �� IG-� �3) AN EXTERIOR LIGHT SHALL BE INSTALLF� ON THE SECO(m FLOOR EXTERIOR D�O�OR� . �� 16-35 (1) THE SECOND FLOOR REAR EXIT DOOR SHALL BE REF ITH A CORE D00 : Alm DEADBOLT LOCKING DEVICE TO INCLUDE REPLAC E OF TH GE�STORM DOOR� � COMPLIANCE DATE IMMEDIATELY INSPECTOR B � HOUSING,INSPECTOR r _ - � CODE ENFORCEMENT DIVISION � Department of Community Development City of Oshkosh o.r�KO.� �I OLAT I ON C CT I ON Nt?T I C ON THE WATER / ORRE E Date Inspected JULY Zg, 1� OCCUPANCY INSPECTED TWO FAMILY DWELLING BEING USEP AS A ROOMING HOUSE ADDRESS IO5 WEST $fH AVENUE OWNERS NAME .IFRRY KnI�IAI ADDRESS �i� NORTH MAIN STREET NOTICE DELIVERED/EXPLAINED TO MAILED cc • ITEM # ORDER FINDINGS OF INSPECTION 9, 16-35 (3) THE SHOWER STALL BASE IS DETERIORATm WITH CHIPPF� Alm PEELING AREA�, IT APPEARS THAT ATTEMPTS I-IAVE BEEN MADE TO REPAIR IT BY PAINTING MIHHICH HAS FAILED� THE BASE SHALL BE PROPERLY REFINISHED WITH A PERMANENT 7YPE FINISH, 1�, 16-34 (3) A GFI ELECTRICAL WALL RECERTACLE SHOULD BE INSTALLED IN THE VANITY SINK ' RuGi�i GF THC Sr�OtJD F�OuR i�NiT� ll, NFPA S� THERE IS NO GAS SHUTOFF VALVE ON THE SUPPLY OF THE SECAI� FLOOR STOVE� IZ� IG-� �S) THE SECOND FLOOR GAS STOVE IS FILTHY Af�ID SHALL BE CLEANm A(m CHECKm FOR PROPER OPERATION OR REPLACm� �..�'� 16-35 (1) THE KITCHEN SINK CABINET IN THE SECOfm FLOOR UNIT IS SEVERELY DAMAGED ; �; ON THE BOTTOM DUE TO WATER LEAKING� THE CABINET SHALL BE REPLACm� ; , ! 14, 16-35 (3) UNAPPROVED MATERIALS SHAVE BEEN USm TO MAKE A WASTE REPAIR UVDER THE KITCHEN SINK WHICH HAS ALSO CRE4TED AN OPEN SEWER, PU�'1BER REQUIRED� � '" 1 ; .1.5, 16-34 (3) GFI ELECTRICAL WALL RECEPTACLES SHOULD BE INSTALLFD OVER THE KITCHEN � , SINK� 16, 1E-35 (1) THE TOILET ROOM FLOOR COVERING IN THE 5EC0[m FL�R TOILET ROOM SHALL BE � REPLACED TO A SURFACE CAPABLE OF BEING CLERNm A(VD KEPT SANITARY� 1 v� 16-34 (2c) THE SCREEN IN THE SECOND FLOOR TOILPTRO'OM SHALL BE REPLACm� A WIN- 4 :; DOWS IN THE LIVING UNIT SHALL BE E�UIPRF� WITH SCREENS EQUAL TO�� OF THE FLOOR AREA OF THE ROOMS THEY SERVE� Ig. 16-3j U) A NUN�ER OF SMOKE DETECTORS ARE IMPROPERLY INSTALLm IN THE ROOMS AI� THE HALLWAYS AND STAIRWELLS OF BOTH LIVING ITS� 19, 16-35 (1) THE SECO(� FLOOR KITCHEN FLOOR CARPET SHALL B R PLACm� T & DI TY, f IMMEDIATELY �� COMPLIANCE DATE INSPECTOR L � HOUSING IN PECTOR 1 1 { �'�� r � CODE ENFORCEMENT DIVISION � Department of Community Development City of Oshkosh o.�Ko..r� �I OLAT I ON C RR CT I ON N�T I CE ON 7HE WATER / V H JJ Date Inspected JULY 29, 1� OCCUPANCY INSPECTED 11^IO FAMILY DWELLING BEING USEP P.S ROOMING HOUSE ADDRESS IOS WEST �TH AVENUE OWNERS NAME ADDRESS NORTH MAIN STREET NOTICE DELIVERED/EXPLAINED TO cc : ITEM # ORDER FINDINGS OF INSPECTION ZO, 16-35 (1) THE WATER DAMAGF� SUBFLOOR NEXT TO THE KITCHEN SINK OF THE SECOIVD FLOOR ; LIVING UNIT SHALL BE REPLACFS: Z�� 16-37 (5) THE FIRST Afm SEC01� FLOOR UNITS ARE INFESTm H1ITH COCKROACHES. A PRO— " FESSIONAL EXTERMINATOR SHALL BE CONTRACTm TO ELIMINATE THE ROACHES� A = COPY OF THE EXTERMINATION BILL WILL BE REGUIRED FOR COMPLIANCE� _ FIRST FLOOR LIVING UNIT �FOUR ROOMS RENTm II�IVIDUALLY) �� 16-33 (9) THE LOWER REAR DOOR INTO THE DVdELLING SHALL BE EQUIPPm WITH A DEADBOLT S LOCKING DEVICE� �� 16-33 (6) A CODE COMPLIANT HAI�RAIL SHALL BE INSTALLm ON THE OPEN SIDE OF THE B�ASFJ`1ENT STEPS� Z4, 16-35 (c) THE BROKEN PANE OF GLASS IN THE LOWER KITCHEN SOUTH WINDOW SHALL BE RE— PLACED� �� 16-35 (3) THE LOWER R4THROOM SINK IS RUSTING OUT AROUND THE DRAIN AND SHALL BE REPLACEl� PER INSTRUCTIONS FROM THE PLUN�ING INSPECTOR� 26, 1Cr35 (1) THE DAMAGED FRONT DCTERIOR DOOR TO THE BUILDING SHALL BE REPLACm� ADDITIONAL SECOIm FLOOR VIOIJ�TIONS v� 16-35 (1) THE ROOM DOOR ON ROOM � 5 IS DAMAGED AND SHALL BE REPLACED� ; ; � ; 2g, 16-35 (1) THE ROOM DOOR ON ROOM � IS DAMAGED Alm SHALL BE REPLACm� � . ALL REC�UIRED PERMITS SHALL BE OBTAINm ON OR BEFO AUGUST � Ig�, � INSPECTIONS WILL BE MADE TO ASSURE COMPLIANCE� H BUILDI SPECTOR � ; SHALL BE CONTACTED FOR RECIUIREMENTS OF LIVING NIT SEPARA ONS� IMMEDIATELY UFD � COMPLIANCE DATE INSPECTOR HOUSING SPECTOR