HomeMy WebLinkAbout21784-Building (front steps) 11/22/2013 CITY OF OSHKOSH INSPECTION SERVICES DIVISiON ROOM 205 �
215 CHURCH AVE DEPARTMENT OF COMMUNITY DEVELOPMENT �
PO Box 1130 OSHKOSH
OSHKOSH WI 54903-1130 CORRECTION NOTICE
ON THE WATER
Issue Date 11/22/2013 Re Issue Date _ Complies No
Address 625 W 11TH AVE :
Sentto ✓ Owner MARK/STEPHANIE M LATTERY _ 625 W 11TH AVE OSHKOSH WI 54902 -6309
Required for Occupancy j Occupancy Single Family
Introduction An inspection of your front steps has revealed the following violation(s)of the Oshkosh Municipal Code,which shali be
corrected by the compliance dates specified for each item. It is the responsibility of every property owner to confirm
compliance with these orders before the compliance date as specified.
Item# 1 Code SPS321.04 Complies No Comply By 12/22/2013
Description The handrails/guardrails for the front stairs is not compliant. The handrails will have to comply with current code
requirements. A graspable handrail is required and a guardrail located between 30"-38"of the nosing of the treads.
Handrails and guardrails shall be constructed to prevent the through passage of a sphere with a diameter of 4"or larger. (A
handout is attached to provide additional clarification)
Item# 2 Code SPS321.04 Complies No _ Compty By 12/22/2013
Description Treads and Risers. Risers may not exceed 8 inches in height and treads shall be a minimum of 9 inches wide measured
horizontally from nosing to nosing,with any variation in uniformity in each tread or riser not varying by more that 3/8"for the
entire stairway flight. Open risers are also not allowed for stairways. The risers are off due to the excessive slope on the
porch floor. Please call to discuss.
Summarv Please contact this office and/or schedule an inspection to confirm compliance on or before the scheduled due date. If you
have any questions regarding these orders please feel free to contact me at(920)236-5036.
Violations must be corrected and approved by the noted compliance dates of each item. Call for reinspections prior to concealment
and/or occupancy. Upon completing the corrections,the owner/contractor/agent must sign and date at the bottom of this notice
and return it to the Inspection Services Division by the Compliance Date of 12/22/2013
Office hours are Monday through Friday 7:30 a.m. -4:30 p.m.or by appointment.To schedule inspections please call the Inspection
Request lin t 236- the address, permit number(when applicable),and the nature of what needs to be inspected.
Signature C,,, � �� Date <<I ZG��
Inspected by: Nicole Krahn 236-5036 nkrahn@ci.oshkosh.wi.us
I hereby certify the violations listed on this report have been corrected in compliance with the applicable codes.
Print Name Company
Signature Date
Also Sent to: Bldg ', _
Elec , --- -- - - -- -- ----
_ __ - - —
HVAC -- _ -
----- ----
Plbg �i - - -- _--
Designer 1 - -- -- ---_—
Other I ---- _— - - --- -- — -- .-
Inspector - - ---- - ------ -