Loading...
HomeMy WebLinkAbout21632-Final Electrical Violations (10/08/2013) Cy'i�OF OSHKOSH INSPECTION SERVICES DIVISION ROOM 205 � �215 CHURCH AVE DEPARTMENT OF COMMUNITY DEVELOPMENT � J PO Box 1130 ! OSHKOSH WI 54903-1130 CORRECTION NOTICE OSHKOSH ON THE WATER Issue Date 10/8/2013 Re Issue Date Complies No Address 347 W 15TH AVE Sent to ✓ Owner JEROME R OECHSNER 347 W 15TH AVE OSHKOSH WI 54902 -6515 Required for Occupancy Occupancy Introduction While conducting the final electrtical inspection,the following violations were noted. Item# 1 Code NEC 334.12(B)(4) Complies No Comply By 11/07/2013 Description Types NM and NMS.Types NM and NMS cables shall not be used in wet or damp locations(below grade) Item# 2 Code NEC 406.3(D)(3) Complies No Compty By 11/07/2013 Description Where attachment to an equipment grounding conductor does not exist in the receptacle enclosure,the installation shall comply with(D)(3)(a), (D)(3)(b), or(D)(3)(direct replacement or GFCI w/no E.G. label.)3-prong (grounded)receptacles are installed @ 2 wire locations Item# 3 Code NEC 110.3(B) Complies No Compfy By 11/07/2013 Description (B) Installation and Use Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.-Attachment plug and cord on garbage disposal are not approved , Item# 4 Code NEC 406.8(B)(1) Complies No Comply By 11/07/2013 Description 15-and 20-Ampere Receptacles in a Wet Location 15-and 20-ampere, 125-and 250-volt receptacles installed in a wet location shall have an enclosure that is weatherproof whether or not the attachment plug cap is inserted.-Exterior receptacle box has only a gasketed,flip cover. 21632 Page 1 of 2 Item# 5 Code MHC 16-34A(3)a Complies No Compiy By 11/07/2013 Description Every outlet and fixture shall be properly installed and shall be maintained in a good and safe working condition and shall be connected to the source of the electric power in a safe manner.All living units shall be provided with safe and adequate electrical facilities, fixtures&wiring. Light buibs missing in basement sockets. Receptacle covers not installed. Summarv Please make arrangements to have these violations corrected in the next 30 days. Feel free to contact me with any concerns or questions at 236-5274. Violations must be corrected and approved by the noted compliance dates of each item. Call for reinspections prior to concealment and/or occupancy. Upon completing the corrections,the owner/contractor/agent must sign and date at the bottom of this notice and return it to the Inspection Services Division by the Compliance Date of 11/7/2013 Office hours are Monday through Friday 7:3,0 a.m. -4:30 p.m.or by appointment.To schedule inspections please call the Inspection Request line at 23 1 8 n ' � r�s,permit number(when applicable),and the nature of what needs to be inspected. Signature Date/ � . Inspected by: Adam Krause 236-5274 akrause@ci.oshkosh.wi.us I hereby certify the violations listed on this report have been corrected in compliance with the applicable codes. Print Name Company Signature Date Also Sent to: Bldg ✓ Elec GROVER ELECTRIC 1650 S OAKWOOD RD OSHKOSH WI 54904 -8347 HVAC — — Plbg — �— Designer — — Other — �— Inspector — — i 21632 Page 2 of 2