HomeMy WebLinkAbout2013-Final Inspection �
CITY OF OSHKOSH INSPECTION SERVICES DIVISION ROOM 205 �
' 215 CHURCH AVE DEPARTMENT OF COMMUNITY DEVELOPMENT �
PO Box 1130 CORRECTION NOTICE OSHKOSH
OSHKOSH WI 54903-1130
ON THE WATER
Issue Date 9/10/2013_ Re Issue Date Complies No
Address 822 W 4TH AVE
Sent to ✓ Owner � JAMES H EWING 1215 WALNUT ST OSHKOSH WI 54901 -3653
Required for Occupancy I Occupancy
Introduction While conducting a final inspection the following violations were noted.
Item# 1 Code NEC 314.17(A) Compiies No Comply By 10/10/2013
Description Openings through which conductors enter shall be effectively ciosed.
Item# 2_ Code MEC 334.30 Complies No Compty By 10/10/2013
Description Nonmetallic-sheathed cable shall be supported and secured by staples, cable ties, straps, hangers,or similar fittings
designed and installed so as not to damage the cable, at intervals not exceeding 1.4 m (4 1/2 ft)and within 300 mm(12 in.)
of every outlet box,junction box,cabinet,or fitting.
Item# 3 Code NEC 300.4(B)(1) Complies No Comply By 10/10/2013
Description In both exposed and concealed locations where nonmetallic-sheathed cab�es pass through either factory-or field-punched,
cut, or drilled slots or holes in metal members,the cable shall be protected by listed bushings or listed grommets covering
all metal edges that are securely fastened in the opening prior to installation of the cable. -Cable run through beam flanges
Item# 4 Code SPS 384.20(5)(g) Complies No Comply By 10/11/2013
Description Floor drains shall be provided with removable strainers of suffcient strength to carry the anticipated loads.The floor drain
shall be constructed that it can be cleaned and the drain inlet shall be accessible at all times. '**NO FLOOR DRAIN
STRAINER""
Item# 5 Code SPS 382.40(7) Complies No Comply By 10/11/2013
Description SIZING OF WATER SUPPLY PIPING.The sizing of the water supply system shall be based on the empirical method and
limitations outlined in this subsection or on a detailed engineering analysis acceptable to the department."`*'`NEED TO
HAVE WATER CALCULATION SHEET TO VERIFY PROPER SIZING OF WATER DISTRIBUTION***
Item# 6 Code SPS 21.04 Complies No Comply By 10/11/2013
Description Code compliant exits are required off the front and side doors of the house. This is to include compliant footings, landings,
handrails, guardrails,treads and risers, etc.
Code compliant steps are also required to the basement. Verify tread widths and riser heights.
Item# 7 Code SPS 23.086 Complies No Comply By 10/11/2013
Description Duct support is required for the furnace venting and for the rigid ductwork. (10"round ducts-min 18ga galv. steel x 2"@ 12'
o/c) (up to 60"perimeter rectangle ducts-min 22 ga galv steel x 1"@ 10'o/c) (PVC pipe support max.48"o/c).
21483 Page 1 of 3
Item# � Code SPS 22 Complies No Comply By 10/11/2013
Description Insulation is required to be installed in the boxsills.
Item# 9 Code SPS 21.02 Complies No Comply By 10/11/2013
Description install the wall under the porch joist where the trench footing was installed.
Item# 10 Code SPS 22.37 Complies No Comply By 10/11/2013
Description Draftstop all penetrations through the floor sheathing. Seal the opening into the tub/shower unit.
Item# 11 Code COMM 21.04 Complies No Comply By 10/11/2013
Description Provide additional support for the handrail to the basement.
Item# 12 Code SPS 23.08 Complies No Comply By 10/11/2013
Description A register cover is required for the kitchen vent under the cabinet. Ductwork is required to be connected to the space to bring
the duct out to the toe kick of the cabinet(the underfloor space of the cabinet can not be used as a duct).
item# 13 Code SPS 21.24 Complies No Comply By 10/11/2013
Description All siding is required to be installed by November 1 st as outlined in your letter that we agreed upon. In addition all soffit and
fascia openings are required to be sealed to prevent rodents from entering. Failure to comply will result in citations and ;
court action. '
21483 Page 2 of 3
Item# "14 Code SPS 20 Complies No Comply By 10/11/2013
Description An occupancy permit is required prior to occupancy of this structure. It was noted at the inspection that this structure is being
rented out without final approvals and an occupancy permit.
Summarv Please correct the above violations and request a re-inspection within the next 30 days. Office hours are Monday-Friday
7:30-4:30pm. If you have questions feef free to contact me at 236-5036.
Violations must be corrected and approved by the noted compliance dates of each item. Call for reinspections prior to concealment
and/or occupancy. Upon completing the corrections,the owner/contractor/agent must sign and date at the bottom of this notice
and return it to the Inspection Services Division by the Compliance Date of 10/10/2013
Office hours are Monday through Friday 7:30 a.m.-4:30 p.m.or by appointment.To schedule inspections please call the Inspection
Request line at 236- 128 noting the address, permit number(when applicable),and the nature of what needs to be inspected.
Signature �l �-�1� 1 Date �/ �� ��
Inspected by: Nicole Krahn 236-5036 nkrahn@ci.oshkosh.wi.us
I hereby certify the violations listed on this report have been corrected in compliance with the applicable codes.