HomeMy WebLinkAbout21279-Minimum Housing (07/19/2013)
Violation(s) of MUN 16-35A(2) at 803 W Murdock Ave – 7/12/13
Violation(s) of MUN 20-8 & NFGC 10.10.7 at 803 W Murdock Ave – 7/12/13
Violation(s) of NFGC 10.10.7 & MUN 17-36A at 803 W Murdock Ave – 7/12/13
Violation(s) of MUN 17-36A at 803 W Murdock Ave – 7/12/13
Violation(s) of MUN 16-35A(1)(c) at 803 W Murdock Ave – 7/12/13
� CITY OF OSHKOSH INSPECTION SERVICES DIVISION ROOM 205 �
215 CHURCH AVE DEPARTMENT OF COMMUNITY DEVELOPMENT �
PO Box 1130 OSHKOSH
OSHKOSH WI 54903-1130 CORRECTION NOTICE
ON THE WATER
Issue Date 7/19/2013 Re Issue Date _ Complies No
Address 803 W MURDOCKAVE
Sent to ✓ Owner ' PAUL C GIESE N1203 S CREEK DR GREENVILLE WI 54942 -8559
Required for Occupancy � Occupancy
Introduction An inspection of your rental property(living unit)following a tenant complaint revealed the following violations of the Oshkosh
Minimum Housing Code which shall be corrected by the compliance dates specified for each item. If you have any questions
regarding the requirements of this notice please contact me immediately at(920)236-5137.
tem# 1 Code ss 101.647 _ Complies No _ Comply By 07/26/2013
Description The owner of a dwelling shall install a functional carbon monoxide detector in the basement of the dwelling and on each floor
level except the attic, garage, or storage area of each dwelling unit. Except as provided under par. (b)the occupant of the
dwelling unit shall maintain any carbon monoxide detector in that unit. (b) If any occupant gives written notice to the owner that
the carbon monoxide detector is not functional,the owner shall provide,within 5 days after receipt of that notice, any
maintenance necessary to make that carbon monoxide detector functional. **Install the required CO detectors.
Item# 2 _ Code 20-8 Complies No _ Comply By 07/26/2013
Description No person shall perform or permit the performance of any plumbing work without properly obtaining a permit. A licensed
plumber is required for all work to be done in rental units. *"No permit on file for installing a new water heater or sump pump.
Contact your plumber and have them obtain the required permit.
�tem# 3 Code NFGC 10.10.7 _ Complies No Comply By 07/26/2013
Description Joints between sections of connector piping and connections to flue collars or draft hood outlets shall be fastened with sheet
metal screws or other approved means. ''*Install screws on joints of venting and connection to the draft hood.
Item\4 Code MUN 16-35A(2) Complies No Comply By 08/18/2013
Description Every outside stair, every porch, every guardrail and every appurtenance thereto shall be so constructed as to be safe to use
and capable of supporting the load that normal use would cause to be placed thereon, and shall be kept in sound condition&
good repair. '*Install new fasteners on stair platform. The whole top can tip up currently.
It�w.# 5 Code MUN 16-35A(1)(c) Complies No Comply By 08/18/2013
Description All windows in rental dwellings shall be capable of being opened and closed easily and remain open without the use of props.
Windows shall be free of chipped, peeling paint, loose or missing glazing compound, broken panes of glass and be weather
tight. ""One of the windows in a bedroom has been caulked in place and may be the reason the window does not latch.
Remove the caulking and check that the top sash is up all the way and can latch.
� 21279 Page 1 of 2
Item# 6 Code MUN 17-36A Complies No Comply By 08/18/2013
Description All building foundations shall be maintained. *"At inspection some of the foundation walls were found to be deflecting.
Hoirzontai cracks were found in some courses of block. Contact a foundation repair contractor to assess the foundation and
� make repairs to ensure the foundation walls will not deflect further or collapse.
Summarv It is the responsibility of every property owner to confirm compliance with these orders before the compliance date(s)as
specified. Please contact this office on or before the scheduled due date(s)to schedule a re-inspection of the property.
Violations must be corrected and approved by the noted compliance dates of each item. Call for reinspections prior to concealment
and/or occupancy. Upon completing the corrections,the owner/contractor/agent must sign and date at the bottom of this notice
and return it to the Inspection Services Division by the Compliance Date of g/18/2013
Office hours are Monday through Friday 7:30 a.m. -4:30 p.m.or by appointment.To schedule inspections please call the Inspection
Request line at 236-5128 noting the address, it number(when applicable),and the nature of what needs to be inspected.
Signature ��_„,,�_ •� ri��.� Date �
Inspected by: Andrew Prickett 236-5137 aprickett�ci.oshkosh.wi.us
I hereby certify the violations listed on this report have been corrected in compliance with the applicable codes.
Print Name Company
Signature Date
Also Sent to: Bldg I _
Elec - _ — -
HVAC
Plbg -� -- -- — — — — — - _
Designer j _
Other _ - -- — — 54901 ---
Inspector
2�2�9 Page 2 of 2