Loading...
HomeMy WebLinkAbout2012-Minimum Housing Violations , CITY OF OSHKOSH INSPECTION SERVICES DIVISION ROOM 205 � 215 CHURCH AVE DEPARTMENT OF COMMUNITY DEVELOPMENT PO Box 1130 CORRECTION NOTICE osHKOSH OSHKOSH WI 54903-1130 ON THE WATER Issue Date 4/17/2012 Re Issue Date Complies No Address 556 PLEASANT ST Sent to ✓ Owner � CAROLE J SCHMIDT 653 S HILL ST HORTONVILLE WI 54944 -0000 Required for Occupancy ' Occupancy Introduction An inspection of your rental property(living unit)following a tenant complaint revealed the following violations of the Oshkosh Minimum Housing Code which shall be corrected by the compliance dates specified for each item. If you have any questions regarding the requirements of this notice please contact me immediately at(920)236-5137. Item# 1 Code MUN 16-34A(3)(a) Complies No Comply By 05/17/2012 Description Every outlet and fixture shall be properly installed and shall be maintained in a good and safe working condition and shall be connected to the source of the electric power in a safe manner. Install cover plates for any open junction boxes. Discontinue the use of extension cords to provide pernament power for basement lights. Properly abandon electrical wiring (wires found hanging). Install knockout plugs on open junction box knock outs. Properly support NM cable in basement. Install cover plates on outlets where missing. Fix hanging fixtures in closets and outlets that pull out or push into the wall. Contact a licensed electrician. Item# 2 Code MUN 16-33A(7) Complies No Comply By 04/24/2012 IMMEDIATELY Description All dwelling units,vacant or occupied, shall be provided with working, approved smoke detectors one each in the basement first and second floors. Common area smoke detectors(basements)are the sole responsibility of the property owner. The owner shall replace batteries once per year or at the beginning of new tenancies. Written responsibilities shall be given to the occupants concerning smoke detectors. 2nd floor did not have a working smoke detector. Item# 3 Code MUN 16-35A(3) Complies No Comply By 05/17/2012 Description Cracked/damaged/leaking fixtures or other plumbing conditions,which create un-sanitary conditions or unusable fixtures, shall be replaced/repaired by a licensed plumber with permit. Laundry hook up found leaking. Supply piping is undersized. Abandon or repipe. See photo for location. Item# 4 Code MUN 16-35A(1)(a) Complies No Comply By 05/17/2012 Description Every floor,floor covering,wall, ceiling, kitchen counters&tops, cupboards&exterior doors etc shall be kept in good repair. Replace the water damaged ceiling tiles. Item# 5 Code MUN 16-34A(2)(c) Complies No Comply By 05/17/2012 Description All habitable room windows/door windows shall be effectively screened with screens in good serviceable condition. Replace the two torn screens. 18972 Page 1 of 2 Item# 6 Code MUN 17-36D Complies No Comply By 05/17/2012 Description All openings where rodents, pigeons, insects might enter shall be properly and effectively sealed. Repair the holes in the fascia/soffit. Summarv It is the responsibility of every property owner to confirm compliance with these orders before the compliance date(s)as specified. Please contact this office on or before the scheduled due date(s)to schedule a re-inspection of the property. �olations must be corrected and approved by the noted compliance dates of each item. Call for reinspections prior to concealment and/or occupancy. Upon completing the corrections,the owner/contractor/agent must sign and date at the bottom of this notice and return it to the Inspection Services Division by the Compliance Date of 5/17/2012 Office hours are Monday through Friday 7:30 a.m. -4:30 p.m. or by appointment.To schedule inspections please call the Inspection Request line at 236-5128 noting the addr , ermit number(when applicable),and the nature of what eeds to be inspected. Signature Date �/� Inspected by: Andrew Prickett 236-5137 aprickett@ci.oshkosh.wi.us I hereby certify the violations listed on this report have been corrected in compliance with the applicable codes. Print Name Company Signature Date Also Sent to: Bldg ' - Elec ', - ' HVAC ---- — - Plbg - Designer - Other __ _ _ _ - Inspector ' 18972 Page 2 of 2 Violation(s) of MUN 16-34A(3)(a) at 556 Pleasant St – 4/12/12 Violation(s) of MUN 16-35A(3) & 16-34A(3)(a) at 556 Pleasant St – 4/12/12 Violation(s) of MUN 16-34A(3)(a) at 556 Pleasant St – 4/12/12 Violation(s) of MUN 16-34A(3)(a) at 556 Pleasant St – 4/12/12 Violation(s) of MUN 16-34A(3)(a) at 556 Pleasant St – 4/12/12 Violation(s) of MUN 16-34A(3)(a) at 556 Pleasant St – 4/12/12 Violation(s) of MUN 16-34A(3)(a) at 556 Pleasant St – 4/12/12 Violation(s) of MUN 16-35A(1)(a) & 16-34A(3)(a) at 556 Pleasant St – 4/12/12 Violation(s) of MUN 16-34A(2)(c) at 556 Pleasant St – 4/12/12 Violation(s) of MUN 16-34A(3)(a) at 556 Pleasant St – 4/12/12 Violation(s) of MUN 16-34A(3)(a) at 556 Pleasant St – 4/12/12 Violation(s) of MUN 16-34A(3)(a) & 16-33A(7) at 556 Pleasant St – 4/12/12 Violation(s) of MUN 17-36D at 556 Pleasant St – 4/12/12