CITY OF OSHKOSH INSPECTION SERVICES DIVISION ROOM 205 � L
215 CHURCH AVE DEPARTMENT OF COMMUNITY DEVELOPMENT
� �
PO Box 1130 CORRECTION NOTICE OSHKOSH
OSHKOSH WI 54903-1130 ON THE WATER
Issue Date 9/5/2013 Re Issue Date Complies No
Address 320 PROSPECTAVE
Sent to ✓ Owner JASON E/DONALD D LAPLANTE 448 W 7TH AVE OSHKOSH WI 54902 -5922
Required for Occupancy Occupancy Two Family
Introduction Upon receiving a neighborhood complaint it was noted that construction has commenced without obtaining the required
building permit.
Item# 1 Code NEC 334.15(B) Complies No Comply By 10/05/2013
Description Cable shall be protected from physical damage where necessary by rigid metal conduit, intermediate metal conduit,electrical �
metallic tubing, Schedule 80 PVC rigid nonmetallic conduit, or other approved means. ""`WIRING ENTERING ELECTRICAL
PANEL NEEDS PROTECTION***
t
Item# 2 Code NEC 314.25 Complies No Comply By 10/05/2013
Description Each outlet box shall have a cover,faceplate, lampholder,or luminaire. '""COVERS NEED TO BE INSTALLED ON ALL
ELECTRICAL BOXES""' `
t
Item# 3 Code NEC 314.17(A) Complies No Comply By 10/05l2013
Description Openings through which conductors enter shall be effectively closed. """OPENINGS IN ELECTRICAL BOXES ARE
REQUIRED TO BE PLUGGED PER CODE'*"
Item# 4 Code WI STATS 145.06 Complies No Comply By 10/05/2013
�
Description No person may engage in or work at plumbing in the state unless licensed to do so by the department.This shall not apply to
plumbing work done by a property owner in a one-family building owned and occupied by him or her.
Item# 5 Code MUN 20-8 Complies No Comply By 10/05/2013
Description No person shall perform or permit the performance of any plumbing work, as defined by state statute or regulation adopted by
reference as a part of this Code, unless a permit is first obtained."'"NO PERMIT ON RECORD FOR THE INSTALLATION
OFTWO WATER HEATERS AND THE BATHROOM REMODEL`"*
Item# 6 Code SPS 382.10 Complies No Comply By 10/05/2013
Description Plumbing in connection with all buildings, public and private, intended for human occupancy, shall be installed and maintained
in such a manner so as to protect the health, safety and welfare of the public or occupants and the waters of the state.
*"*CAST IRON FITTING IS CRACKED AND NEEDS TO BE REPLACED'"*
Item# 7 Code SPS 382.31(3)(a) Complies No Comply By 10l05/2013
Description Every trap and trapped plumbing fixture shall be provided with an individual vent, except as otherwise permitted in this chapter.
*'*NO VENT FOR SHOWER AND TOILET ON FIRST FLOOR***
21467 Page 1 of 2
Item# 8 Code SPS 382.60 Complies No Comply By 10/05/2013
Description Piping hangers and anchors shail be securely attached to the building's structure at intervals to support the piping and its
contents, but not at intervals greater than those specified in Table 82.60.*"*NO SUPPORT HANGERS ON SHOWER DRAIN"'*
Item# 9 Code SPS 382.30(9) Complies No Comply By 10/05/2013
Description DRAIN FITTINGS AND CONNECTIONS. Drain fittings,connections, devices and methods of installation shall not obstruct or
retard the flow of water,wastes, sewage or air in the drain system or venting system in an amount greater than the normal
frictional resistance to flow, unless as otherwise permitted in this chapter or unless approved by the department.*"'DRAINAGE
PATTERN FITTINGS NEED TO BE INSTALLED IN DRAIN PIPING FOR SHOWER ALSO PROPER SIZE DRAIN PIPING FOR
SHOWER PER CODE IS 2"*"*
Item# 10 Code MUN 7-43 Complies No Comply By 10/05/2013
Description Before commencing construction, installation, alteration or remodeling of any heating,ventilating,or air conditioning system, or
part of a system,a permit shall first be secured."""NO PERMIT ON RECORD FOR HEATING"""
Item# 11 Code NFPA 54 10.3.1 Complies No Comply By 10/05/2013
Description Unused openings in masonry chimneys shall be sealed."*'OPENING IN CHIMNEY NEEDS TO BE CLOSED/SEAL AROUND
VENTING FOR WATER HEATERS"""
Item# 12 Code UDC 321.15(1) Complies No Comply By 10/05/2013
Description The dwelling and attached structures shall be supported on a structural system designed to transmit and safely distribute the
loads to the soil.'*'FOOTINGS ARE REQUIRED FOR STRUCTURAL SUPPORT OF THE BUILDING AND SHALL BE
INSTALLED PER CODE**"
Summarv The permit must be applied for within the next 10 days to avoid citations. Permit hours are Monday-Friday 7:30am-4:30pm.
If you have questions feel free to contact me at 236-5052.
Violations must be corrected and approved by the noted compliance dates of each item. Call for reinspections prior to concealment ;
and/or occupancy. Upon completing the corrections,the owner/contractor/agent must sign and date at the bottom of this notice
and return it to the Inspection Services Division by the Compliance Date of 10/5/2013
Office hours are Monday through Friday 7:30 a.m. -4:30 p.m.or by appointment.To schedule inspections please call the Inspection
Request line at 236-51 oting the add ess, pe it number(when applicable),and the nature of what needs to be inspected.
Signature Date ^'��
Inspecte by: Jer Fabisch 236-5052 JFabisch@ci.oshkosh.wi.us
I hereby certify the violations listed on this report have been corrected in compliance with the applicable codes.
Print Name Company
Signature Date
Also Sent to: Bldg ! _
�
Elec -- ---- _ _
HVAC _
Plbg -- — _—
Designer .
Other� _ -
Inspector
21467 Page 2 of 2