HomeMy WebLinkAbout20940-Electric (05/22/2013) ;. ° CITY O�OSHKOSH INSPECTION SERVICES DIVISION ROOM 205 � 215 CHURCH AVE DEPARTMENT OF COMMUNITY DEVELOPMENT � PO Box 1130 OSHKOSH osHKOSH wi sasos-„so CORRECTION NOTICE ON THE WATER Issue Date 5/22/2013 Re Issue Date Complies No Address 1636 CENTRAL ST Sent to ✓ Owner ACCU PROPERTIES LLC PO BOX 2664 OSHKOSH WI 54903 -2664 Required for Occupancy Occupancy Introduction WPS personnel informed the inspection department of code violations pertaining to your electrical service. I have verified the violations and now request that you address the situation. Item# 1 Code NEC 230.51 Complies No Comply By 06/21/2013 : Description Service entrance conductors shall be supported by staples or other approved means. 12"from service heads and enclosures, '' 30"intervals. Item# 2 Code Mun Code 11-50 Complies Not Checked Comply By 06/21/2013 Description In the event of damage to an electrical service,whether by storm, deterioration,vandalism, or other causes, all electrical services, 60 Amperes or less shall be replaced with a minimum of 100 Ampere service and comply with current code requirements. Be sure all aspects of your electrical service are in compliance. Item# 3 ode NEC 314.23 Complies No Comply By 06/21/2013 Description En losures within the scope of this article shall be supported in accordance with one or more of the provisions in 314.23(A) through(H).-Meter socket loose on house , coP Y �.����D MAY 3 0 2013 ��hA�T11E�7 OF E�l�lfl�lY1TY DEVELOPME.YI' �§$��'xO�i 3BItY10E5 DI�'ISIQ'V 20940 Page 1 of 2 Item# �4 Code Mun code 11-22 Complies Not Checked Comply By 06/21/2013 Description Electricians licensed with the city required to do wiring on any building that is not a single family residence owned and occupied by the owner.Wiring done for the purpose of rental or sale of such residences is also limited to a licensed electrician Summarv Please contact an electrician to correct the problem in the next 30 days. Feel free to contact me at 920-236-5274 with any questions as well. Violations must be corrected and approved by the noted compliance dates of each item. Call for reinspections prior to concealment and/or occupancy. Upon completing the corrections,the owner/contractor/agent must sign and date at the bottom of this notice and return it to the Inspection Services Division by the Compliance Date of 6/21/2013 Office hours are Mond thr ' y 7:30 a.m. -4:30 p.m.or by appointment.To schedule inspections please call the Inspection � Request line at 2 ' g the ddress, permit number(when applicable),and the nature of what needs to be inspected. Signature �r�/'�`�� Date ���„z� � Inspected by: Adam Krause 236-5274 akrause@ct.oshkosh.wi.us I hereby certify the viotations listed on this report have been corrected in compfiance with the applicable codes. ����7� �' �1�'�-��� �c� � - Prz�pc��+�P 5 �-L� Print ame Company � �� � � S-�- � `� � I Signature Date Also Sent to: Bldg _ Elec _— HVAC _— Plbg _— Designer _— ✓ Other WPS-ERIC STRANGEWAY 3300 N MAIN ST PO BOX 420 OSHKOSH WI 54901 -0420 Inspector 20940 Page 2 of 2 CITY OF OSHKOSH INSPECTION SERVICES DIVISION ROOM 205 215 CHURCH AVE DEPARTMENT OF COMMUNITY DEVELOPMENT � PO Box 1130 OSHKOSH WI 54903-1130 CORRECTION NOTICE OSHKOSH ON THE WATER Issue Date 5/22/2013 Re Issue Date Complies No Address 1636 CENTRAL ST Sent to ✓ Owner ACCU PROPERTIES LLC PO BOX 2664 OSHKOSH WI 54903 -2664 Required for Occupancy Occupancy Introduction WPS personnel informed the inspection department of code violations pertaining to your electrical service. I have verified the violations and now request that you address the situation. Item# 1 Code NEC 230.51 Complies No Comply By O6/21/2013 Description Service entrance conductors shall be supported by staples or other approved means. 12"from service heads and enclosures, 30"intervals. Item# 2 Code Mun Code 11-50 Complies Not Checked Comply By 06/21/2013 Description In the event of damage to an electrical service,whether by storm,deterioration,vandalism, or other causes,all electrical services,60 Amperes or less shall be replaced with a minimum of 100 Ampere service and comply with current code requirements. Be sure all aspects of your electrical service are in compliance. Item# 3 Code NEC 314.23 Complies No Comply By 06/21/2013 : Description Enclosures within the scope of this article shall be supported in accordance with one or more of the provisions in 314.23(A) through(H).-Meter socket loose on house 20940 Page 1 of 2 Item# 4 Code Mun code 11-22 Complies Not Checked Comply By 06/21/2013 Description Electricians licensed with the city required to do wiring on any building that is not a single family residence owned and occupied by the owner.Wiring done for the purpose of rental or sale of such residences is also limited to a licensed electrician Summarv Please contact an electrician to correct the problem in the next 30 days. Feel free to contact me at 920-236-5274 with any questions as well. Violations must be corrected and approved by the noted compliance dates of each item. Call for reinspections prior to concealment and/or occupancy. Upon completing the corrections,the owner/contractor/agent must sign and date at the bottom of this notice and return it to the Inspection Services Division by the Compliance Date of 6/21/2013 Office hours are Mond thr ' y 7:30 a.m.-4:30 p.m.or by appointment To schedule inspections please call the Inspection Request line at 2 ' g the ddress, permit number(when applicable),and the nature of what needs to be inspected. Signature Date ��'�„zr- � Inspected by: Adam Krause 236-5274 akrause@ct.oshkosh.wi.us I hereby certify the violations listed on this report have been corrected in compliance vyith the applicable codes. : Print Name Company Signature Date Also Sent to: Bldg Elec — — HVAC — — Plbg — . Designer — — ✓ Other WPS-ERIC STRANGEWAY 3300 N MAIN ST PO BOX 420 OSHKOSH WI 54901 -0420 Inspector — 20940 Page 2 of 2 Violations at 1636 Central St: Service not properly supported