HomeMy WebLinkAbout0101066-BuildingOSHKOSH
ON THE WATER
Job Address 3229 BELLFIELD DR
Designer
CITY OF OSHKOSH
BUILDING PERMIT -APPLICATION AND RECORD
Owner CREATIVE CUSTOM HOMES
Contractor CREATIVE CUSTOM HOMES, INC
Category 110 - New Single Family
Type ~11 Building (~ Sign O Canopy C) Fence C) Raze
No 0101066
Create Date 03/04~2003
Plan E1-017-0303R
Zoning R-1
Unfinished/Basement
Finished/Living
Garage
Foundation
Occupancy Permit
Park Dedication
Use/Nature
of Work
Class of Const: 8
1453 Sq. Ft. Rooms 4
1453 Sq. Ft. Bedrooms 3
576 Sq. Ft. Baths 2
Poured Concrete (~ Floating Slab (~) Pier
Concrete Block (~) Post (~) Treated Wood
Required Flood Plain No
Required # Dwelling Units 1
qSFR/1 stow home with a 2 car attached garage, 12'x12' rear deck.
Height 18 Ft.
Stories I
Other
Height Permit Not Required
# Structures I
Size IRR
Canopies
Signs
HVAC Contractor MARTENS HEATING & COOLING
EleCtric Contractor VAN ERT ELECTRIC
Fees: Valuation $98,400.00 Plan.,,Approval
Plumbing Contractor HANSON QUALITY PLUMBING
$75.00 Permit Fee Paid
[] Permit Voided
$377.00 Park Dedication $100.00
Date 04/28/2003 Final/O.P. 00/00/0000
In the performance of this work I agree to perform ail work pursuant to rules governing the described construction.
Signature Date
Agent/Owner
Address 1087 VELPAVE GREEN BAY WI 54303 - 0000
Telephone Number 819-2655
OSHKOSH
ON THE WATER
Name CREATIVE CUSTOM HOMES
GRADE STAKE FORM
Address 3229 BELLFIELD DR
Lot 51 Block
Subdivision 1st Add to Village Green Zone
Street Number Lot Dimensions
Building Grade Elevation Stakes Set At Site 03/05/2003 Set By
Grade Stake Number 6904
Create Date 03/04/2003
Ward
D.W.G. BK-586, P~67
b~ Sidewalk Existing
Department of Public Works
I, the undersigned, owner or agent of the above described property agree to have~, grade established before excavation
has commenced.
Wisconsin Department of Industry, WISCONSIN UNIFORM Application No.
Labor and Human Relations
Safety and Buildings Division BUILDING PERMIT 0101066
P.O. Box 2509
Madison, WI 5370%2509 APPLICATION Parcel No.
Wisconsin Statues 101.63, 101.73
r~ Constr [] HVAC [] Elec [] Plbg [] Erosion [] Other:
Owner's Name Mailing Address Telephone No.
CREATIVE CUSTOM HOMES 1087 VELP AVE GREEN BAY WI 54303 - 0000 920-819-4396
~ontractor: L~ Con~_~ Elec[] HVAC ~ Plbg Lic/Cert # Mailing Address '' Telephone No.
CREATIVE CUSTOM HOMES, INC 679085 1087 VELP AVE GREEN BAY WI 54303 - 0 819-2655
Contractor: L_J Con ~ Elec ~ HVAC~ Plbg Li~Ce~ ~ Mailing Address Telephone No.
VAN ERT ELECTRIC 170921 2000 PROGRESS WAY ~UKUANA W~ ~130 - 0 920-766-3888
Contractor: ~ Con L~ Elec~ HVAC ~ Plbg~Lic/Ced~ Mailing Address Telephone No.
MARTENS HEATING & COOLING 8831 P.O. BOX 106 WAU~U WI 54980 - 106 (920) 68~0111
Contractor:~ Con ~ Elec~ HVAC~ Plbg Lic/Ce~ Mailing Address Telephone No.
HANSON QUALITY PLUMBING 550 N BLUEMOUND RD APPLETON WI 54914 -0 730-0205
~;~.: ~¢~ Sq. ft. 1/4, 1/4,Section ,T N,R E(or)W
Building Address Subdivision Name Lot No. Block No.
3229 BELLFIELD DR 1st Add to Village Green 51
Zoning District(s) Zoning Permit No. Front Rear Left Right
~:~, ~ .~ ~ Setbacks ~ ft I fl, fl.
New ~ Repair ~ Single Family Entrance Panel ~ Forced Air Furnace Nat. L.P. Oil Elec. Solid Sola
~ Alteration ~ Raze ~ Two Family Size: 200 amp ~ Radiant Baseboard or Panel Fuel Gas ,
Garage Se~ice: -- ~ Heat Pump Space Htg
~ Addition ~ Move ~ Other (print): ~ Overhead Water Htg
~ Other: :~ Underground ~ Boiler
~ Central Air Conditioning * ~ Dwelling unit will have 3 kilowatt or
~ Site Constructed ~Concrete ~ Other
Unfinished ~ Manufactured ~ Mason~ more installed electric space heating equip.
....................... ~'"' '"'" ' ~ Infiltration control option is: ~ Full sealing
Sewer
of joints. ~ Blower door test. ~ Exterior
~.~ ,,,.~ ,. ,~:~ ~ Treated Wood ~ Municipal a~r infiltration barder.
Basement 1453 Sq. ff. ~ ~ Other
1-Stow
Living Area 1453 Sq. ff. ~ 2-Stow ~ Septic
Permit No. Envelope 0 BTU/HR
:Garage 576 Sq. ~. ~ Other ~ Seasonal ~~~ Infiltration 0 BTU/HF
~ Permanent ~ Municipal Utility
~ Plus Basement ~ Other
~ Private On-Site Well $146,900.00
The appli~nt agrees to comply with all applicable codes, statues and ordinan~s and with the conditions of this permit, understands that the issuance of
the permit creates no legal liability, expr~ implied, on the Depa~ent or municipality; and ~difies that all the above information is accurate.
APPROVAL CONDITIONS This permit is issued p~ant to Che f~llowing conditions. Failure to comply may result in suspension or
revocation of this permit or other penalty
see standard conditions of approval
; ~'¢~ ~'~";~ ~ Town ~ Village ~ Ci~ ~ County ~ State of:
',~ ', * ~:~ Municipality Number of Dwelling Location:
City Of Oshkosh~ 7 0 - 2 6 6
Plan Review $75.00 ~ Construction
Inspection~ HVAC Name Nicole Krahn
~ Electrical
Wis. Permit Seal $30.00 ~ Plumbing Date 3/4/03
Other ~ Erosion
Total $105.00 ~ 288719 Cert. No. 248101
SBD-5823 fR. 07/92)
OSHKOSH
ON THE WATER
Job Address
PARKLAND DEDICATION FEE COLLECTION RECORD
3229 BELLFIELD DR
CREATIVE CUSTOM HOMES
Date 04~28/2003
Name
Address 1087 VELP AVE
GREEN BAY WI 54303
Subdivision 1st Add to Village Green
Lot 51
Building Permit Number 0101066
Number of Dwelling Units
Number of Structures
Fee Required $100.00 Fee Paid
Owner's Signature ~"~') ~ ~.,~/,.,4/'
Inspector's Signature
Date
Date
CITY OF OSHKOSH
STANDARD CONDITIONS OF APPROVAL
Project Address -'~'~'Z~--'~ ~~'~"~ Permit#
Please read the following information and sign at the bottom to acknowledge that yOU have read
and agree to comply with these conditions.
All habitable rooms must be provided with 8% light and 3.5% ventilation. Bedrooms
located onthe second floor or below ground level must be provided with egress windows
in addition to the light and ventilation requirements. Basement windows are also
required to have window well areas in accordance with ILHR21.03. '
Garage spaces shall be separated from the dwelling unit in accordance with ILHR 21.08.
The door and frame assembly between the dwelling unit and an attached garage shall be
labeled by an independent testing agency as having a minimum fire-resistive rating of 20
minutes. All drywall joints are required to be taped/sealed unless the joints are fitted so
that the gap is no more than a dimes thickness (1/20-inch) and backed by solid wood or
drywall with the joints staggered.
Ail penetrations in exterior walls must be sealed prior to the insulation inspection. This
includes holes in the top and bottom plates, gaps around heating ducts, and holes in the
return air spaces.
Smoke detectors are required on every floor and within 6' of all bedrooms. The smoke
detectors are required to be hardwired and interconnected.
Hydromassage tubs are required to have an access panel to motor. The access panel must
be 'accessible without removing the finish of the house.
0
All overframing must.be designed by the truss matiufacturer, according to standards set
by the truss plate institute, or structural calculations must be provided prior to the rough
building inspection.
7. Truss plans must be submitted and approved prior to framing the roof.
Truss plans including the tress layout must be provided on site at the rough building
inspection. In addition to the truss plans, microlam calculations must be prOvided on site
at the rough building inspection for all microlams with point loads on them.
Calculations must be provided for all cantilevered floors with point loads. Floor trusses
and TJI's must be designed for the cantilevered areas.
10.
The property owner and applicant is responsible for compliance with ILHR 21.125
(Erosion Control). When installing access drives, a minimum of 2"-3" diameter stone is
required in addition to a minimum of 6" depth, 30'-5~q' length, and 14'-20' width. ErOsion
control measures must be maintained ~ii:t,he l:~awn'i~,establi~hed., i,~
11.
All storm sewer inlets must be protected with approved erosion control devices. Tracking
(i:e. sediment) must be removed from the street at the end of each workday. Repair any
siltation or erosion damage to adjoining surfaces and drainageways resulting from land
development or disturbing activities.
12.
The building placard must be posted on site at all times. Once the rough framing is up
the placard must be posted on the patio 'doOr or on akitCh~n'wihd0'~vi" i~tfi~'~pl~/~ai/d'i~ fi6't .............................
present at any inspection, stop work orders will be posted. Additional placards Can be
obtained through our department if the cards are misplaced.
13.
All mechanicals must be roughed in prior to requesting the rough building irisPectionl If
on the inspection the mechanicals are not roughed in, the inspection Wil[faii and'as 100
re-inspection fee will be charged.
14.
Attached is a copy of the final inspection checklist. At the final inspection all items on
this list must be completed to avbid fl/~ $100 re'inspection £eeper iii~5~ti6fi.
15.
When requesting final inspections please note that a minimum of 2 days notice is needed
from the time the inspection is ready. Furniture is only allowed to be placed in the center
of the garage floor and a minimum of a 3' pathway must be provided around the walls of
the garage. At the final inspection no furniture or personal belon~ing~ ~e~aii0w~d in'the .........
house. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in
place due to the electrical inspeCtor needing to look at' the~ p6w~r's~rvin~"{he ~applian~es~2
A 6' stepladder must be on site at the final inspection to provide access to the attic.
16.
The building placard must remain on the patio dooi' or on a kitchen window until
occupancy is approved. Occupancy is not allowed prior to the placard having all of the
final inspection approved stickers on the backside. If occupancy occurs prior to the
inspections being approved daily citations will be issued with no further notice being
given.
17.
All site grading must be done in accordance with the approved drainage plan on file in the
public works office, 3rd floor.