Loading...
HomeMy WebLinkAbout20894-Elec, Bldg, HVAC (05/14/2013) CITY OF OSHKOSH INSPECTION SERVICES DIVISION ROOM 205 � 215 CHURCH AVE DEPARTMENT OF COMMUNITY DEVELOPMENT � PO Box 1130 OSHKOSH WI 54903-1130 CORRECTION NOTICE OSHKOSH ON THE WATER Issue Date 5/14/2013 Re Issue Date Complies No Address 705 E PARKWAY AVE Sent to ✓ Owner KEEN CAPITAL MANAGEMENT LLC 815 S KELLER PARK DR APPLETON WI 54914 -854T Required for Occupancy Occupancy Introduction While conducting the final inspections,the following violations were noted. Item# 1 Code DSPS 321.04(1)(c) Complies No Comply By 06/13/2013 Description Treads and Risers. Risers may not exceed 8 inches in height and treads shall be a minimum of 9 inches wide measured horizontally from nosing to nosing,with any variation in uniformity in each tread or riser not varying by more that 3/16 inch. Front entry steps Item# 2 Code DSPS 321.04 Complies Comply By O6/13/2013 Description Guardrai�s. All openings befinreen floors, and open sides of landings, platforms, balconies or porches that are more than 24" above grade or a floor shall be protected with guardrails that measure a minimum of 36"above the floor.All stairs with 3 or more riser shall have graspable handrails 30-38"above the nosing. Item# 3 Code DSPS 321.22 Complies No Comply By O6/13/2013 Description Ccolumns and beams-unless designed by structural anafysis-columns shall bear on a footing pad and be secured, intermediate beams shall be installed with lateral restraint and be secured properly-basement shoring Item# 4 Code NEC 314 Complies No Comply By 06/13/2013 Description An electrtical junction box in the basement is missing a cover Item# 5 Code DSPS 323.02 Complies No Comply By 06/13/2013 Description Incomplete ducting-a heating contractor shall connect the 1st floor register to the furnace Item# 6 Code MHC 16.35(1)(a) Complies No Comply By O6/13/2013 Description Every floor,floor covering,wall, ceiling, kitchen counters&tops,cupboards&exterior doors etc shall be kept in good repair-Kitchen floor incomplete in doorway+access panels on tub need to be installed. 20894 Page 1 of 2 Item# 7 Code DSPS 321.05(3) Complies No Comply By 06/13/2013 Description Safety glazing is required at stairs and landings as follows:Within 4 feet vertically of a tread or landing in a stairway and within one foot horizontally of the near edge of the tread or landing and;within 4 feet vertically of the floor and 3 feet horizontally of the nosing of the top or bottom tread of a stair Summarv Please correct the above violations and request a re-inspection within the next 30 days. Office hours are Monday-Friday 7:30-4:30pm. If you have questions feel free to contact me at 236-5274. �olations must be corrected and approved by the noted compliance dates of each item. Call for reinspections prior to concealment and/or occupancy. Upon completing the corrections,the owneNcontractoNagent must sign and date at the bottom of this notice and return it to the Inspection Services Division by the Compliance Date of 6/13/2013 Office hours are Monday throu ' a 7:30 a.m. -4:30 p.m.or by appointment To schedule inspections please call the Inspection Request line at 236- 2 n t th�dress, permit number(when applicable),and the nature of what needs to be inspected. Signature s� ,.� Date Inspected by: Adam Krause 236-5274 akrause@ci.oshkosh.wi.us I hereby certify the violations listed on this report have been corrected in compliance with the applicable codes. Print Name Company Signature Date Also Sent to: Bldg _ Elec _ HVAC _ Plbg _ Designer _ Other .— Inspector 20894 Page 2 of 2