HomeMy WebLinkAbout20853-Plumbing (05/02/2013) CITY OF OSHKOSH INSPECTION SERVICES DIVISION ROOM 205 � 215 CHURCH AVE DEPARTMENT OF COMMUNITY DEVELOPMENT � PO Box 1130 OSHKOSH OSHKOSH WI 54903-1130 CORRECTION NOTICE ON THE WATER Issue Date 5/2/2013 Re Issue Date Complies No . Address 1535 SANDERS ST Sent to ✓ Owner LOREN R DIECK 1535 SANDERS ST OSHKOSH WI 54902 -6361 Required for Occupancy Occupancy Single Family Introduction The following violations were noted at the plumbing inspection. Item# 1 Code Mun 20-8 Complies No Comply By 06/01/2013 Description No person shall perform or permit the perFormance of any plumbing work, as defined by state statute or regulation adopted by reference as a part of this Code, unless a permit is first obtained. '*'NO PERMIT FOR PLUMBING ON RECORD FOR THE INSTALLATION OF THE SUMP PIT AND PUMP IN BASEMENT'** Item# 2 Code SPS 382.36(5)(a) Complies No Comply By 06/01/2013 Description Segregation of wastewater. Stormwater or clearwater piping may not connect to a sanitary drain system. "**NO DRAIN TILE IS ALLOWED TO DISCHARGE INTO THE SANITARY SEWER/NEED TO PLUG THE STORM DRAIN TILE THAT IS GOING INTO THE FLOOR DRAIN IN THE BASEMENT**' 20853 Page 1 of 2 Item# 3 Code SPS 382.36(8) Complies No Comply By 06/01/2013 Description An interior sump shall be provided with an airtight cover when installed less than 1"above the finished floor level.Vents serving a solid covered sump shall terminate a minimum of one inch above finished floor.'**SUMP PIT IN BASEMENT NEEDS TO HAVE A SEALED COVER WITH A VENT EXTENDED FROM IT PER CODE*"' Summarv The permit must be applied for within the next 10 days to avoid citations. Permit hours are Monday-Friday 7:30am-4:30pm. If you have questions feel free to contact me at 236-5052. Violations must be corrected and approved by the noted compliance dates of each item. Call for reinspections prior to concealment and/or occupancy. Upon completing the corrections,the owner/contractor/agent must sign and date at the bottom of this notice and retum it to the Inspection Services Division by the Compliance Date of 6/1/2013 Office hours are Monday through Friday 7:30 a.m. -4:30 p.m.or by appointment.To schedule inspections please call the Inspection Request line at 2 -5128 no ' g the ddress, permit number(when applicable),and the nature of what needs to be inspected. Signature � Date �''�� Ins cte y: Jerry Fabisch 236-5052 JFabisch�ci.oshkosh.wi.us I hereby certify the violations listed on this report have been corrected in compliance with the applicable codes. Print Name Company Signature Date Also Sent to: Bldg _ Elec _ HVAC _ Plbg _ Designer _ Other � - Inspector 20853 Page 2 of 2