Loading...
HomeMy WebLinkAbout0101067-BuildingOSHKOSH ON THE WATER Job Address Designer Category Type Zoning R-1 3233 BELLFtELD DR 110 - New Single Family CITY OF OSHKOSH BUILDING PERMIT -APPLICATION AND RECORD Owner CREATIVE CUSTOM HOMES Create Date Contractor CREATIVE CUSTOM HOMES, INC ~1 Build_!ng. O Sign No 0101067 0310512003 Canopy (~ Fence O Raze Plan E1-018-0303R Class of Const: Size IRR Unfinished/Basement 132 Sq. Ft. Rooms 3 Finished/Living 1824 Sq. Ft. Bedrooms 3 Garage 399 Sq. Ft, Baths 2 Foundation O Poured Concrete ~ Floating Slab (~) Pier ~ Concrete Block (~) Post ~) Treated Wood Occupancy Permit Required Flood Plain No Park Dedication .Required # Dwelling Units Height 20 Ft. Stories Bi-level Other [] ProjectionI Canopies 0 Signs 0 Height Permit Not Required # Structures 1 Use/Nature qSFR/Bi-level home with a 2 car attached garage, and a 4'x6' rear deck. of Work HVAC Contractor MARTENS HEATING & COOLING Electric Contractor VAN ERT ELECTRIC Fees: Valuation $98,900.00 ' Plan Approval Plumbing Contractor HANSON QUALITY PLUMBING $75.00 Permit Fee Paid $377.00 Park Dedication $100.00 Date 04/28/2003 Final/O.P, 00/00/0000 [] Permit Voided J In the performance of this work I agree to perform all work pursuant to rules governing the described construction. Signature Date Agent/Owner GREEN BAY WI 54303 - 0000 Telephone Number Address 1087 VELP AVE 819-2655 OSHKOSH ON THE WATER Name CREATIVE CUSTOM HOMES Lot 52 GRADE STAKE FORM Grade Stake Number 6906 Address 3233 BELLFlELD DR Create Date 03/05/2003 Block Ward Subdivision 1st Add to Village Green Zone Street Number Lot Dimensions LL Sidewalk Existing Building Grade Elevation Stakes Set At Site 03/06/2003 Set By mb 565/40 DePartment of Public Works I, the undersigned, owner or agent of the above described property agree to have the grade established before excavation has commenced. ~,{~ ~' /~..~. ~~ ~'~¢'~J/ 'Wisconsin Department of Industry, wISCONSIN UNIFORM Application No. Labor and Human Relations Safety and Buildings Division BUILDING PERMIT 0101067 P.O. Box 2509 APPLICATION Parcel No. MadiSon, WI 53701-2509 Wisconsin Statues 101.63, 101.73 ~:" ':'3 ~ ~'~,;,~" ¢~'~'~ ~" ~: [] Constr [] HVAC [] Elec [] Plbg [] Erosion [] Other: Owner's Name Mailing Address Telephone No. CREATIVE CUSTOM HOMES 1087 VELP AVE GREEN BAY WI 54303.-..0000 920-819-4396 Contractor: b~J Con~} Elect, HVAC ~ Plbg Lic/Ce~ ¢ Ma ng Address Telephone No. CREATIVE CUSTOM HOMES, INC 679085 1087 VELP AVE GREEN BAY WI 54303 - 0 819-2655 Contractor: ~ Con ~ Elec b~ HVAC~ Plbg Li¢Ce~ ¢ Mailing Address Telephone No. VAN ERT ELECTRIC :170921 2000 PROGRESS WAY KAUKUANA WI 54130 - 0 920-766-3888 Contractor: ~ Con ~ Elec~ HVAC ~ PIb~Lic/Cert¢ Mailing Address Telephone No. MARTENS HEATING & COOLING 8831 P.O. BOX 106 WAUKAU WI 54980 - 106 (920) 68~0111 Contractor:~ Con ~ Elec~ HVAC~ Plbg bi¢Ce~¢ Mailing Address Telephone No. HANSON QUALITY PLUMBING 550 N BLUEMOUND RD APPLETON WI 54914 -0 ~730-0205 , !~, , ~ ~ ~ ~ ..~ Lo Area Sq. ~. 1/4, 1/4,Section ,T N,R E(or)W Building Address Subdivision Name Lot No. Block No. 3233 BELLFIELD DR 1st Add to Village Green 52 Zoning District(s) Zoning Permit No. Front Rear Left Right Setbacks ft. ,~,,,~:.~tt ~ New ~ Repair ~ Single Family Entrance Panel ~ Forced Air Furnace Fuel Nat L.P. Oil Bec. Solid Sola Two Family Size: 200 amF ~ Radiant Baseboard or Panel Gas * ~ Alteration ~ Raze Garage Se~ice: ~ Heat Pump Space Htg ~ ~ ~ ~ ~ ~ ~ Addition ~ Move ~ Other (print): ~ Overhead Water Htg ~ ~ ~ ~ ~ ~ ~ Underground ~ Boiler ~ Central Air Conditioning * ~ Dwelling unit will have 3 kilowatt or ~ Other:~: ,~ ~ '~ ~ O~er more installed electric space heating equip. ~~ ~?¢ ~ Site Constructed ~ Concrete ~ Infiltration control option is: ~ Full sealing Unfinished ~ Manufactured ~ Masonw Sewer of joints. ~ Blower door test. ~ Exterior Basement 132 Sq. ~. ~ Treated Wood ~ Municipal air infiltration barrier. Living Area 1824 Sq. ~. ~ 1-Stow ~ Other ~ Septic ~~ Permit No. Envelope 26294 BTU/HR Garage 399 Sq. ft. ~ 2-Stow ~ Other ~ Seasonal Infilt~tion 15691 BTU/HR Bi.level ~ Pe~anent ~ Municipal Utility ~~ ~ Plus Basement ;~ Other ~ Private On-Site Well $146,900.00 The applicant agrees to comply with all ap~cable codes, statues and ordinances and with the conditions of this permit, understands that the issuance of the permit creates no legal liability, expr~ implied, onthj De~rtment or municipality; and ceAifies that all the above information is accu~te. This permit is issued ~rsuant to the following ~nditions. Failure to comply may result in suspension or APPROVAL CONDITIONS revo~tion of this permit or other penal~ see standard conditions of approval ~ Town ~ Village ~ City ~ Coun~ ~ State of: Municipality Number of Dwelling Location: City Of,~shkosh 7 0 - 2 6 6 Review $75.00 ~ Construction Plan HVAC Name Nicole Krahn inspection ~ Electrical Wis. Permit Seal $30.00 ~ Plumbing Date 3/5/03 Other ~ Erosion Total $105.00 ~ ~ 288720 Cert. No. 248101 SBD-5823 (R. 07/92) OSHKOSH ON THE WATER Job Address 3233 BELLFIELD DR Name Address 1087 VELP AVE Subdivision 1st Add to Village Green Building Permit Number 0101067 Number of Dwelling Units Fee Required PARKLAND DEDICATION FEE COLLECTION RECORD CREATIVE CUSTOM HOMES Date 04/28~2003 GREEN BAY Wi 54303 Lot 52 1 Number of Structures $100.00 Fee Paid Owner's Signature ~~~~~~~ Inspector's Signature Date Date CITY OF OSHKOSH Project Address ~..t~:::~ Permit # Please read the following information and sign at the bottom to acknowledge that you have read and agree to comply with these conditions. o All habitable rooms must be provided with 8% light and 3.5% Ventilationl BedrOomS ' located on the second floor or below ground level must be provided with egress windows in addition to the light and ventilation requirements. Basement windows are also required to haVe window well areas in accordance with ILHR 21.03. Garage spaces shall be separated from the dwelling unit in accordance with ILHR 21.08. The door and frame assembly between the dwelling unit and an attached garage shall be labeled by an independent testing a~ency as having a minimum fire-resistive rating of 20 minutes. All drywall joints are required to be taped/sealed unless the joints are fitted so that the gap is no more than a dimes thickness (1/20-inch) and backed by solid wood or drywall with the joints staggered. All penetrations in exterior walls must be sealed prior to the insulation inspection. This includes holes in the top and bottom plates, gaps around heating ducts, and holes in the return air spaces. Smoke detectors are required on every floor and within 6' of all bedrooms. The smoke detectors are required to be hardwired and interconnected. Hydromassage tubs are required to have an access panel to motor. Theaccess panel must be accessible without removing ~he flnlSh Ofthehou~e. ' Ail overframing must be designed by the truss manufacturer, according to standards Set by the truss plate institute, or structural calculations must be provided prior to the rough building inspection. Truss plans must be submitted and approved prior to framing the roof. Truss plans inclUding the truss iayoiit rnus~ be provided 0n site 'at the roUgh building inspection. In addition to the truss plans, microlam calculations must be provided on site at the rough building inspection for all microlams with point load~ 6h ~th-~m~ Calculations must be provided for all cantilevered floors with point loads. Floor trusses and JI s must be designed for the cantdevered areas. 10. 11. 12. 13. 14. 15. 16. The property owner and applicant is responsible for compliance with ILHR 21.125 (Erosion Control). When installing access drives, a minimum of 2"-3" diameter, stone is required in addition to a miffim~. ~urn_gf..6.!.l depth, 30'-50' length, and 14'-20' width. Erosion control measures must be.maintained url~til the,' !awn:i~'~establishe~.:.i . ...... , ............ ~ All storm sewer inlets must be protected with approved erosion control devices. Tracking (i.e. sediment) must be removed from the stre..e[.ot ~end. p[~.e.a, gh.~o~r~ay. Repair any siltation or erosion damage to adjoining surfaces and drainageways resulting from land development or disturbing activities. The building placard must be posted on site at all times. Onc~..the rough framing is up the placard must be posted on the patio door or on a kitchen window. !f t_he placard is not present at any inspection, stop work orders will be posted. Additional placards can be obtained through our department if the cards are misplaced. All mechanicals.m~sl, be..roughed in prior to requesting the rough building inspection. If on the inspection the mechanicals are not roughed in, the inspection will fail and a $100 re-inspection fee will be charged. Attached is a copy of the final inspection checklist. At the final inspection all items on this list must be completed to avoid the $100 re-inspection fee per inspection. When requesting final inspections please note that a minimum of 2 days notice is needed from the time the inspection is ready. Furniture is only allowed to be placed in the center of the garage floor and a minimum of a 3' pathway must be provided around the walls of the garage. At the final inspection no furniture or personal belongings are allowed in the house. Appliances such as the.s~ov¢, refrigerator, washer, and dryer are not to be set in place due to the electrical ig~pector needing to look at the power serving the appliances. A 6' stepladder must be on siteat the final~ inspection to provide access to the attic. The building placard must remain on the patio door or on a kitchen window until occupancy is approved. Occupancy is not allowed prior to the placard having all of the final inspection approved stickers on the ba~ks~iO~,_[~.99c~upancy occurs prior to the inspections being approved daily citations will be issued with no fm-ther not!~e..~,¢ing given. 17. public works office, 3rd floor. All site grading must be done in accord .ance with. t~!~ approved drainage plan on file in the Lo~ ~O0a'