HomeMy WebLinkAboutCN - piping and outlets (07/01/93) CODE ENFORCEMENT DIVISION
DEPARTMENT OF COMMUNITY DEVELOPMENT
CITY OF OSHKOSH, WISCONSIN
VIOLATION / CORRECTION NOTICE
JULY 2 , 1993 DATE INSPECTED JULY 1 , 1993
OCCUPANCY INSPECTED RESIDENTIAL (SINGLE FAMILY)
ADDRESS 2 218 MT. VERNON
OWNERS NAME SHOWCASE CUSTOM HOMES
ADDRESS '?755 ALGOMA BLVD OSHKOSH 54901
NOTICE DELIVERED/EXPLAINED TO: MAILED FOLLOWING INSPECTION
cc: D. HANSEN PLBG 680 W. 3RD OSHKOSH 54901
ITEM # ORDER FINDINGS OF INSPECTION
1 ILHR82 . 21 EXCEPT AS PROVIDED IN SUBS. (12) AND (17) , VENT PIPING SERV-
(15)b. 2 . ING A WALL-OUTLET FIXTURE MAY NOT OFFSET HORIZONTALLY LESS
THAN 36 INCHES ABOVE THE FLOOR, BUT IN NO CASE LOWER THAN
THE ELEVATION OF THE HIGHEST FLOOD LEVEL RIM OF ANY FIXTURE
SERVED BY THE VENT. (KITCHEN SINK)
2 ILHRB2 . 21 REINSPECTIONS. WHENEVER THE PLUMBING OFFICIAL FINDS THAT
(1) (b) 5 . THE WORK OR INSTALLATION DOES NOT PASS ANY INITIAL TEST OR
INSPECTION, THE NECESSARY CORRECTIONS SHALL BE MADE TO COM-
PLY WITH THIS CHAPTER. THE WORK OR INSTALLATION SHALL THEN
BE RESUBMITTED FOR INSPECTION TO THE PLUMBING INSPECTOR.
DEFICIENCIES MUST BE CORRECTED AND APPROVED BEFORE
CONCEALMENT. CALL (414) 236-5050 FOR IN 'ECTI.N.
COMPLIANCE DATE: IMMEDIATELY INSPECTOR: WALTER J. CALLIES