Loading...
HomeMy WebLinkAbout20735-Minimum Housing, Electric & Plumbing (04/04/2013) CITY OF OSHKOSH INSPECTION SERVICES DIVISION ROOM 205 � 215 CHURCH AVE DEPARTMENT OF COMMUNITY DEVELOPMENT PO Box 1130 CORRECTION NOTICE OSHKOSH OSHKOSH WI 54903-1130 ON THE WATER Issue Date 4/4/2013 Re Issue Date Complies No Address 1229 SCHOOLAVE Sent to ✓ Owner DANIEL H KRIZ 247 W SOUTH PARK AVE A OSHKOSH WI 54902 -6537 Required for Occupancy Occupancy Two Family Introduction An inspection of your property following a complaint revealed the following violations of the Oshkosh Municipal Code,which shall be corrected by the compliance dates specified for each item. Item# 1 Code Mun 16-34A (3)a Complies No Comply By 05/04/2013 Description Every outlet and fixture shall be properly installed and shall be maintained in a good and safe working condition and shall be connected to the source of the electric power in a safe manner.All living units shall be provided with safe and adequate electrical facilities, fixtures&wiring. Adequate numbers of electrical receptacles/fixtures are required to prevent extension cord use.""*OUTLET HANGING OUT OF BOX IS NON CODE COMPLYING*** Item# 2 Code NEC 334.15(C) Complies No Comply By 05/04/2013 Description NM cable used on a wall of an unfinished basement shall be permitted to be installed in a listed conduit or tubing. Conduit or tubing shall utilize a nonmetallic bushing or adapter at the point the cable enters the raceway. Metal conduit and tubings and metal outlet boxes shall be grounded.**"NM CABLE SUPPLYING THE OUTLET FOR THE DRYER IS NOT SUPPORTED OR PROTECTED PER CODE*** Item# 3 Code MUN 16-35A(3) Complies No Comply By 05/04/2013 Description Cracked/damaged/leaking fixtures or other plumbing conditions,which create un-sanitary conditions or unusable fixtures, shall be replaced/repaired by a licensed plumber with permit. **'LEAKING PIPES FROM UPSTAIRS UNIT CAUSING DOWNSTAIRS UNIT TO BE DAMAGED BY WATER/SEWAGE*** Item# 4 Code MUN 16-35A(1)a Complies No Comply By 05/04/2013 Description Every floor,floor covering,wall,ceiling, kitchen counters&tops, cupboards&exterior doors etc shall be kept in good repair. ***FLOOR NEXT TO BATHTUB ROTTED AWAY/CEILING AND WALL IN KITCHEN IS BEING DAMAGED BY WATER FROM UPSTAIRS PLUMBING`"' Item# 5 Code MUN 16-35A(6) Complies No Comply By 05/04/2013 Description No owner or operator shall rent to any other person for occupancy or allow any person to occupy any dwelling unit or premises unless it is safe and clean and complies with all provisions of the Minimum Housing Code and Property Maintenance Code. Item# 6 Code SPS 382.10 Complies No Comply By 05/04/2013 IMMEDIATELY Description Plumbing in connection with all buildings, public and private, intended for human occupancy, shall be installed and maintained in such a manner so as to protect the health, safety and welfare of the public or occupants and the waters of the state. """SEVERAL SINKS AND TOILET NOT WORKING, DRAINING PROPERLY/WATER SERVICE IN BASEMENT BEFORE WATER METER IS LEAKING AND NEEDS TO BE REPAIRED PER CODE'** 20735 Page 1 of 2 Item# 7 Code SPS 382.30(11)(g)2 Complies No Comply By 05/04/2013 Description Storm water and clear water connections.'Except as provided in s. SPS 382.36(3), storm drain piping and clear water drain piping may not discharge to a sanitary building drain which connects to a publicly-owned treatment works.***FLOOR DRAIN IN BASEMENT HAS STORM WATER LEAKING INTO IT AND NEEDS TO BE CORRECTED PER CODE""* Summarv It is the responsibility of every property owner to confirm compliance with these orders before the compliance date as specified. Please contact this office on or before the scheduled due date. �olations must be corrected and approved by the noted compliance dates of each item. Call for reinspections prior to concealment and/or occupancy. Upon completing the corrections,the owner/contractor/agent must sign and date at the bottom of this notice and return it to the Inspection Services Division by the Compliance Date of 5/4/2013 Office hours are Monday through Friday 7:30 a.m. -4:30 p.m.or by appointment.To schedule inspections please call the Inspection Request line at 23 -5128 noting e a ress, permit number(when applicable),and the nature of what needs to be inspected. r Signature Date �� � I ected y: Jerry Fabisch 236-5052 JFabisch@ci.oshkosh.wi.us I hereby certify the violations listed on this report have been corrected in compliance with the applicable codes. Print Name Company Signature Date Also Sent to: Bldg _ Elec _ HVAC . Plbg . Designer _ Other _ Inspector 20735 Page 2 of 2