CORRECTION NOTICE
Issue Date 11/16/2000 Compliance Date 12/16/2000 Compliance No
Address 2020 MT VERNON ST Inspected By PLUMBING INSPECTOR
Name Address City State Zip Code
Sent to āf Owner JERRY KOPE,INC P 0 BOX 732 OSHKOSH WI 54903 -0000
u Contractor CJ PLUMBING 117 DIVISION ST NEENAH WI 54956 -
u Other -
U Inspector
u Required for Occupancy Occupancy Notice le First O Final 0 Other
Introduction An inspection of the plumbing on 11/15/00 revealed the following violation(s):
Item# 1 Code Comm 82.31(17)(b)1 Compliance Yes Compliance Date 12/16/2000 IMMEDIATELY
Description A vent stack or a drain stack at least 2 inches in diameter shall be connected upstream of any building drain branch
or building subdrain branch. COMPLIES 11/17/00
Item# 2 Code OMC 20-8(A)5 Compliance No Compliance Date 12/16/2000 IMMEDIATELY
Description RE-INSPECTION FEES REMIT$100.00 DOLLARS TO THE CITY OF OSHKOSH.
Summary
You will be required to call for re-inspection no later than 12/16/00.
DEFICIENCIES MUST BE CORRECTED AND APPROVED BEFORE CONCEALMENT. CALL(920)236-5050 FOR INSPECTION.
Signature Date
Page 1 of 1
INSPECTION SERVICES DIVISION
DEPARTMENT OF COMMUNITY DEVELOPMENT
OSHKOSH CITY OF OSHKOSH,WISCONSIN
ON THE WATER CORRECTION NOTICE
Issue Date 11/16/2000 Compliance Date 12/16/2000 Compliance No
Address 2020 MT VERNON ST Inspected By PLUMBING INSPECTOR
Name Address City State Zip Code
Sent to u Owner JERRY KOPE, INC P 0 BOX 732 OSHKOSH WI 54903 -0000
u Contractor CJ PLUMBING 117 DIVISION ST NEENAH WI 54956 -
LJ Other _ -
Li Inspector
u Required for Occupancy Occupancy Notice 0 First 0 Final 0 Other
Introduction An inspection of the plumbing on 11/15/00 revealed the following violation(s):
Item# 1 Code Comm 82.31(17)(b)1 Compliance No Compliance Date 12/16/2000 IMMEDIATELY
Description A vent stack or a drain stack at least 2 inches in diameter shall be connected upstream of any building drain branch
or building subdrain branch.@@
Item# 2 Code OMC 20-8(A)5 Compliance No Compliance Date 12/16/2000 IMMEDIATELY
Description RE-INSPECTION FEES REMIT$100.00 DOLLARS TO THE CITY OF OSHKOSH.
Summary You will be required to call for re-inspection no later than 12/16/00.
DEFICIENCIES MUST BE CORRECTED AND APPROVED BEFORE CONCEALMENT. CALL(920)236-5050 FOR INSPECTION.
Signature Date
Page 1 of 1
Fixture Listing
Date:January 23,2001
Name: ADAMS(GARY)PLBG Project:NSFR
Street: Street: 2020 MT VERNON ST
City: City:
Non Public Use Fixtures
Hot Cold Total
1 Automatic Clothes Washer 1.00 1.00 1.50
2 Bathtub,with or without shower head 3.00 3.00 4.00
1 Dishwashing Machine 1.00 .00 1.00
2 Hose Bib, 1/2"diameter .00 6.00 6.00
1 Kitchen Sink 1.00 1.00 1.50
2 Lavatory 1.00 1.00 2.00
2 Water Closet,gravity type flush tank .00 4.00 4.00
Total Water Supply Fixture Units 7.00 16.00 20.00
14.0 Gallon per minute demand of the building.Predominatly Flush Tank
15.2 Pressure available for uniform loss.For the table use- 16.0
Maximun Allowable load for Copper Tube Type M, ASTM B88
Nominal Size 1/2 5/8 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4
Actual I.D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935
Value of C 130 130 130 130 130 130 130 130 130 130
Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8
Maximum Gpm 4.5 0 12.5 21.5 32 45 79 121 174 303
Maximum FM WSFU 0 0 4.5 7 16 38 144 369 731 1833
Maximum FT WSFU 5 0 17.5 34 60 110 270 480 776 1833
WATER DISTRIBUTION DATASHEET
Date:January 23,2001
Name: ADAMS(GARY)PLBG Project:NSFR
Street: Street: 2020 MT VERNON ST
City: City:
1. 14.0 Gallon per minute buiding demand,predominatly Flush Tank.
2. 50.0 Low pressure at the Main in Street.
3. .0 Lb loss from a.0 ft difference in elevation from Main in Street to the Water Meter.
4a. 1.1 Lb loss from a 15.0 ft 1" Copper Tube Type K ASTM B88 water service from the Main in Street to the curb stop.
Pressure loss detemined using a C value of 130,inside diameter of.995 and a velocity of 5.8 ft per sec.
4b. 5.9 Lb loss from a 50.0 ft 1" PE Tubing CTS ASTM 2737 AWWA C901 water service from the curb stop to the Water Meter.
Pressure loss detemined using a C value of 150,inside diameter of.860 and a velocity of 7.7 ft per sec.
5. 2.9 Lb loss from a 3/4in Meter .
6. 40.0 Lbs of pressure available at the Water Meter. This value is entered in(B)below.
The(A)value listed below is determined by using the following formula,then rounding the result up.
A= B-(C+D+E) x 100
F
A. 16 Pressure available for uniform loss(psi/100 feet of pipe).
B. 40.0 Lbs of pressure available at the Water Meter.
C. 20.0 Pressure needed at the controlling fixture.MASTER BATHRM
D. 5.2 Lb loss resulting from a 12.0 ft difference in elevation from the Water Meter to the controlling fixture.
E. .0 Lb pressure loss due to a no pressure loss devices serving the controlling fixture.
F. 97.5 Ft Developed length from the 65.0 ft actual length of piping from the Water Meter to the controlling fixture.
Maximun Allowable load for Copper Tube Type M, ASTM B88
Nominal Size 1/2 5/8 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4
Actual I.D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935
Value of C 130 130 130 130 130 130 130 130 130 130
Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8
Maximum Gpm 4.5 0 12.5 21.5 32 45 79 121 174 303
Maximum FM WSFU 0 0 4.5 7 16 38 144 369 731 1833
Maximum FT WSFU 5 0 17.5 34 60 110 270 480 776 1833
Plumbing Permit Work Card
Job Address 2020 MT VERNON ST Permit Number 0081775 Create Date 10/03/2000
Owner JERRY KOPE,INC Contractor CJ PLUMBING
agory 410-Residential-Interior Plan Value $5,700.00
Bathtub /12 Shower Ejector/Grind Dip Well F Prep Sink Gar Drain
Whirlpool Floor Drain 1 1 Water Softner Drink Ftn Sery Sink Soda Disp
Lavatory /r 2 Lndry Tray Local Waste Wait.St. Shamp Sink Coffee Maker
Toilet / 1 2 Lndry Stndp f 1 Clothes Wshr Ice Chest Fir/Wst Sink Int Grease Trap
Res.Sink / 1 Disposal / 1 Bidet Exam Sink Catch Basin Ext Grease Trap
Bar Sink Dishwasher / 1 Beer Tap Sculry Sink Wash Ftn
Water Heater / 1 Sump Pump / 1 Dent.Oper. Hand Sink Urinal
Site Drain Classrm Sink Lab Sink Plaster Sink Standp Rec
Roof Drain Breakrm Sink Sterilizer Surgeons Sink Ice Maker
Use/Nature
of Work
NSFR
Size Material Type # Conn.Type
Sanitary Sewer lā..=__, ___
fiv s A lā 91..E/ li 1 i l S.
Storm Sewer
vi
Water Service
Date 00/00/0000 Type Inspector J Approved
(ia 4t),) ol ' F-ct,,_..e,-e-c 31.° --') I-1 -5 (:.) i
7 6 0K_
to 3s-r
vi (/ .(49 i9/ā ---;:', /---:), 211,LbA, kl-irt\
ID as 0
0 do 361 it-- ve_ 1 III`7
GA