HomeMy WebLinkAbout0154191 - HVAC (replace 2 furnaces) CITY OF OSHKOSH No 154191 10 OSHKOSH HVAC PERMIT -APPLICATION AND RECORD ON THE WATER Job Address 600 S MAIN ST Owner BROOKLYN OFFICE CONDOMINIUMS Create Date 01/17/2013 Contractor ANDERSON HVAC LLC Category 512-Ind.&Comm-Both Plan Inspector Nicole Krahn Fuel H Gas ❑ Oil ❑ Electric ❑ Solar Ell Solid System ❑ New 1 �✓] Replace ❑ Other 1 0 Forced Air Eicliant -- Steam ❑ A/C Vent ❑ Electric I H Hot Water -1 ❑ Suppl. H Con. Burner '', Chimney Type 0 Chimney O Chimney B • Direct Vent 0 Not Applicable Heat Loss I0 As Approved • Existing 0 Not Applicable Value BTU Rate As Per Plan _ 0 Variable • Other Value Use/Nature COMM/REMOVE AND REPLACE 2 FURNACES DUE TO BAD HEAT EXCHANGERS, ELECTRICIAN IS JP ELECTRIC **debit acct of Work Fees: Valuation $7,400.00 Plan Approval $0.00 Permit Fee Paid $142.00 Issued By: (51 -- Date 01/17/2013 ❑ Permit Voided I Parcel Id# In the performance of this work, I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement,the City strongly urges the permit applicant to contact the easement holder(s)and to secure any necessary approvals before starting such activity. Signature Date Agent/Owner Address 2070 ABRAHAM LANE OSHKOSH WI 54904 -7733 Telephone Number 920-230-6963 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number,Type of Inspection (i.e. Footing, Service, Final,etc.),Access into Building if Secure(how do we gain entry),your Name and Phone Number. Unless specified otherwise,we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. Wentz, Sandra From: HVAC PERMIT APPLICATION [Permit App_HVAC @ci.oshkosh.wi.us] Sent: Wednesday, January 16, 2013 9:27 Aril- To: Inspections, Inspections Subject: HVAC Permit Application HVAC PERMIT APPLICATION Date:1/16/2013 9:26:53 AM Permit Fee Account System: YES Job Address: 600 S Main St Owner: Cindy Kuettner Contractor: Anderson HVAC LLC Use Category: Commercial Fuel: Gas System: Replace Type: Forced Air Is Chimney Being Lined? No Liner Size: Manufacturer: Chimney Type: Direct Vent Heat Loss: Existing BTU Rate Other: Description of all Remove and replace 2 furnaces due to bad heat exchangers work being done: Value (Including labor and 7,400.00 all materials including light fixtures): Master Elelctrician: JP Electric 1