Loading...
HomeMy WebLinkAbout20110 - Property Maint (09/21/12) CITY OF OSHKOSH 215 CHURCH AVE INSPECTION SERVICES DIVISION ROOM 205 PO Box 1130 DEPARTMENT OF COMMUNITY DEVELOPMENT OSHKOSH WI 54903-1130 CORRECTION NOTICE OSHKOSH Issue Date 9/21/2012 ON THE WATER Re Issue Date Address 3740 GLENSHIRE LN Complies No Sent to Lij Owner BRANDON/RACHEL HARMON 3740 GLENSHIRE LN OSHKOSH WI 54904 -8513 Required Introduction While conducting the inspection to restore electricity, the following violations were noted. pancy Item# 1 Code NEC 550.10(B) Complies No Comply By 10/21/2012 Description B) Power-Supply Cord. If the mobile home has a power-supply cord, it shall be permanently attached to the distribution panelboard or to a junction box permanently connected to the distribution panelboard, with the free end terminating in an attachment plug cap.A suitable clamp or the equivalent shall be provided at the distribution panelboard knockout to afford strain relief for the cord to prevent strain from being transmitted to the terminals when the power-supply cord is handled in its intended manner. Item# 2 Code Mun code 11-44(A)� ) Complies No Comply By 10/21/2012 Description Should any electrical equipment be found unsafe or dangerous to persons or property,the person owning or using such electrical equipment shall be notified in writing by the Electrical Inspector the need to make the equipment safe-melted device and box at laundry location shall be repaired/replaced as needed. • Summary Please contact an electrician to correct the problem in the next 30 days. Feel free to contact me at 920-236-5274 with any questions as well. Violations must be corrected and approved by the noted compliance dates of each item. Call for reinspections prior to concealment and/or occupancy. Upon completing the corrections, the owner/contractor/agent must sign and date at the bottom of this notice and return it to the Inspection Services Division by the Compliance Date of 10/21/2012 Office hours are Monday through Friday 7:3 a.m. -4:30 p.m. or by appointment. To schedule inspections please call the Inspection Request line at 236 12 notrn 8l .e a ss, permit number(when applicable),and the nature of what needs to be inspected. Signature ���'�"C-- / Date ��. /.../. Inspected by: Adam Krause 236-5274 akrause @ci.oshkosh.wi.us I hereby certify the violations listed on this report have been corrected in compliance with the applicable codes. Print Name Company Signature Date Also Sent to: Li Bldg — .J Elec I — - - HVAC I — U Plbg I _ - �] Designer - J Other _ - - HI Inspector 20110 Page 1 of 1