HomeMy WebLinkAbout19824 - Final on duplex (8/7/12) CITY OF OSHKOSH INSPECTION SERVICES DIVISION ROOM 205 215 CHURCH AVE PO Box 1130 DEPARTMENT OF COMMUNITY DEVELOPMENT OSHKOSH WI 54903-1130 CORRECTION NOTICE OSHKOSH ON THE WATER Issue Date 8/7/2012 Re Issue Date Address 815 W 10TH AVE Complies No Sent to ./ Owner _1 HAROLD BEYER 406 PAWLING ST APT 1 MADISON WI 53704 -5047 L Required for Occupancy Occupancy Two Family Introduction The following violations were noted at the time we did a consult for the final on the duplex.A plumbing permit must be issued to the plumber who is going to be responsible for the plumbing install. Item# 1 Code SPS 382.40(5) Complies No Comply By 09/06/2012 The discharge pipe serving a water heater relief valve shall be installed to drain by gravity flow to a floor served by a floor drain or to a receptor in accordance with s. Comm 82.33. The outlet of the discharge pipe shall terminate within 6"over the floor or receptor, but not less than a distance equal to twice the diameter of the outlet pipe. The outlet of the discharge pipe may not be threaded. "NO DRIP TUBE FOR RELIEF VALVE ON WATER HEATER" Item# 2 Code MUN 20-8 Complies No Comply By 09/06/2012 Description No person shall perform or permit the performance of any plumbing work, as defined by state statute or regulation adopted by reference as a part of this Code, unless a permit is first obtained. " NO PERMIT ON RECORD FOR THE WATER HEATER REPLACEMENT IN BASEMENT" Item# 3 Code SPS 384.20(5)(g) Complies No Comply By 09/06/2012 Description Floor drains shall be provided with removable strainers of suffcient strength to carry the anticipated loads. The floor drain shall be constructed that it can be cleaned and the drain inlet shall be accessible at all times. " NO STRAINERS ON FLOOR DRAINS IN BASEMENT" Item# 4 Code SPS 384.20(4)(a) Complies No --_ Comply By 09/06/2012 IMMEDIATELY The outlet passageway of a fixture shall be free from impairments and of suffcient size to insure proper discharge of the fixture contents under normal conditions. The outlet connection of a fixture which directly connects to the drain system shall be an air and watertight seal. "DRAIN FOR LAUNDRY AND KITCHEN SINK ON FIRST FLOOR NOT CONNECTED PROPERLY TO DRAIN STACK" Item# 5 Code SPS 382.40(8)(f) Complies No --- Comply By 09/06/2012 _ Description All plumbing fixtures, appliances and appurtenances with 3/8"or larger inlet openings and with solenoid actuated quick closing valves shall be provided with water hammer arrestors. "SHOCK ARRESTORS NEED TO BE ADDED TO BASEMENT LAUNDRY WATER SUPPLY" Item# 6 Code MUN 24-6.1 Complies No Comply By 09/06/2012 Description No person(s) shall discharge or cause to be discharged, any polluted waters such as stormwater, groundwater, roof runoff, subsurface drainage or cooling water to any sanitary sewer. "CROSS CONNECTION BETWEEN STORM AND SANITARY SEWER SYSTEM " Item# 7 Code SPS 382.41(3) Complies No Comply By 09/06/2012 IMMEDIATELY ----------- Description A high hazard cross connection situation shall be considered to exist at a water supply hose bibb, faucet,wall hydrant, sill cock or other outlet which terminates with hose threads allowing a hose to be attached. "CROSS CONNECTION PROTECTION NEEDS TO BE INSTALLED ON OUTSIDE HOSE FAUCET AND BASEMENT SINK" 19824 Page 1 of 2 Item# 8 Code SPS 382.31(3)(a) ---_.— Complies No -- __ Comply By 09/06/2012 Description Vents. Every trap and trapped plumbing fixture shall be provided with an individual vent, except as otherwise permitted in this chapter. Vents and venting systems shall be designed and installed so that the water seal of a trap shall be subject to a maximum pneumatic pressure differential equal to one inch of water column. " DRAIN PIPING IN BASEMENT FOR FIRST FLOOR FIXTURES DOES NOT MEET CODE" Item# 9 Code MUN 16-35A(5)O Complies No ---- ---- ----- Comply By 09/06/2012 Description No owner, occupant or operator shall cause any required service, facility, equipment or utility to be removed from, shut off or discontinued for any occupied dwelling unit except for temporary interruption as may be necessary while repairs are in progress. The owner shall give notice to the occupants of any service shutdown. " ELECTRICAL OUTLETS IN BASEMENT NOT SEALED PROPERLY" Item# 10 Code 7-43 7 MUN 43 Complies No Comply By 09/06/2012 Description Before commencing construction, installation, alteration or remodeling of any heating, ventilating, or air conditioning system, or part of a system, a permit shall first be secured." NEED TO PULL PERMIT FOR INSTALLATION OF NC UNIT" Summary Please correct the above violations and request a re-inspection within the next 30 days. Office hours are Monday-Friday 7:30am-4:30pm. If you have questions feel free to contact me at 236-5052. Violations must be corrected and approved by the noted compliance dates of each item. Call for reinspections prior to concealment and/or occupancy. Upon completing the corrections,the owner/contractor/agent must sign and date at the bottom of this notice and return it to the Inspection Services Division by the Compliance Date of 9/6/2012 Office hours are Monday through Friday 7:30 a.m. -4:30 p.m. or by appointment. To schedule inspections please call the Inspection Request line at 236-5 noting the dress, ermit number(when applicable), and the nature of what needs to be inspected. Signature Date 8- 7- (a Inspecte by: erry Fabisch 236-5052 JFabisch @ci.oshkosh.wi.us I hereby certify the violations listed on this report have been corrected in compliance with the applicable codes. Print Name Company Signature Date Also Sent to: i_j Bldg. Elec — — - I HVAC ---------- ---------------- Plbg . — --- ------------------------------ Designer — - Li Other — — - — --------------------- Inspector 19824 Page 2 of 2