HomeMy WebLinkAbout0100773-BuildingOSHKOSH
ON THE WATER
.lob ,Address 1742 W 5TH AVE
Designer
CITY OF OSHKOSH
BUILDING PERMIT - APPLICATION AND RECORD
Owner GREGORY P WEITZ/GAIL PERDUE
Contractor OWNER
Category 111 - Single Family Addition
No 0100773
Create Date 04/11/2003
Plan
Type I(~ Building (~ Sign (~ Canopy (~ Fence ~ Raze
Zoning Class of Const: Size
Unfinished/Basement 0 Sq. Ft. Rooms 0 Height 0 Ft. ~J Projection
Finished/Living 0 Sq. Ft. Bedrooms 0 Stories Canopies
Garage 0 Sq. Ft. Baths 0 Signs
Foundation O Poured Concrete (~ Floating Slab (~ Pier (~ Other
(~ Concrete Block (~ Post (~ Treated Wood
Occupancy Permit Flood Plain Height Permit
Park Dedication # Dwelling Units 0 # Structures 0
Use/Nature SFR/ Single family addition 32' x 10' (dinette and bathroom). All work shall comply with all building codes. SEPERATE PERMITS REQUIRED
of Work FOR ELECTRIC, PLUMBING, AND HVAC.
HVAC Contractor OWNER
Electric Contractor HOMEOWNER
Fees: Valuation $8,800.00 Plan Approval
Issued By:
Plumbing Contractor HOMEOWNER
$0.00 Permit Fee Paid
$80.00 Park Dedication $0.00
Date 04/11/2003 Final/O.P. 00/00/0000
Permit Voided
In the performance of this work I agree to perform all work pursuant to rules governing the described construction.
Signature
Date
Agent/Owner
OSHKOSH
Address 1742 W 5TH AVE WI 54902 - 0000 Telephone Number 233-9157
OSHKOSH
ON THE WATER
Job Address 1742 W 5TH AVE
CITY OF OSHKOSH
BUILDING PERMIT -APPLICATION AND RECORD
Owner GREGORY P WEITZ/GAIL PERDUE
Designer Contractor OWNER
Category 111 - Single Family Addition
Type · Building O Sign (~ Canopy O Fence O Raze
No 0100773
Create Date 04/11/2003
Plan
Zoning Class of Const:
Unfinished/Basement 0 Sq. Ft. Rooms 0 Height 0 Ft.
Finished/Living 0 Sq. Ft. Bedrooms 0 Stories
Garage 0 Sq. Ft. Baths 0
Foundation · Poured Concrete O Floating Slab O Pier O Other
(~ Concrete Block (~ Post (~ Treated Wood
Occupancy Permit Flood Plain Height Permit
Park Dedication # Dwelling Units 0 # Structures
Size
[] Projection
Canopies
Signs
Use/Nature SFPJ Single family addition 32' x 10' (dinette and bathroom). All work shall comply with all building codes. SEPERATE PERMITS
of Work REQUIRED FOR ELECTRIC, PLUMBING, AND HVAC.
HVAC Contractor OWNER
Electric Contractor HOMEOWNER
Fees: Valuation $6,800.00
Issued By: ~
Plumbing Contractor HOMEOWNER
Plan Approval $0.00 Permit Fee Paid
[] Permit Voided r
$60.00 Park Dedication $0.00
Date 04/11/2003 Final/O.P. 00/00/0000
In the performance of this work I agree ,~o perform all work pursuant to rules governing the described construction.
Signature )~ ,~"~/~/~ Date
Agent/Owner
Address 1742W 5TH AVE OSHKOSH WI 54902 - 0000 Telephone Number
233-9157
WIScheck COMPLIANCE REPORT
Wisconsin Uniform Dwelling Code
WIScheck Software Version 1.0 Release 3
TITLE: ADDITION
COUNTY: Winnebago
HEATING TYPE: Non-Electric
DATE: 4-11-2003
DATE OF PLANS: 4-11-03
PROJECT INFORMATION:
MATT HOLLIS
Permit
Checked by/Date
UDC COMPLIANCE: Passes
Code-Allowed UA = 86
Your Home = 85
1.2% Better Than Code
Area or Cavity Cont. Glazing/Door
Perimeter R-Value R-Value U-Value
UA
CEILINGS 306 38.0 0.0
WALLS: Wood Frame, 16" O.C. 302 13.0 3.7
GLAZING: Windows or Doors, Above Grade 40
DOORS 18
FLOORS: Over Unconditioned Space 306 19.0 3.7
CRAWL: Concrete 56" bt/ 48" bg/ 48" insul. 208
HVAC EQUIPMENT: Furnace, 90.0 AFUE
0.350
0.250
5.0
9
21
14
5
12
24
COMPLIANCE STATEMENT: The proposed building design described here is
consistent with the building plans, specifications, and other calculations
submitted with the permit application. The proposed building has been
designed to meet the requirements of the Wisconsin Uniform Dwelling Code.
Builder/Designer Date
TITLE: ADDITION
HEATING EQUIPMENT SIZING S~DMMARY
General Information:
Outdoor Design Temperature:
Conditioned Floor Area:
Average Ceiling Height:
Infiltration,Rate:
Equipment Oversizing Factor:
Loads SuInmary:
Conductive Losses:
Infiltration Losses:
Oversizing Factor Losses:
-15 deg
306 ft2
8.0 ft
0.50 Normalized ACH
15.0%
7207 Btu/hr
1873 Btu/hr
1362 Btu/hr
Total Building Heating Load: 10442 Btu/hr
TITLE: ADDITION
WIScheck INSPECTION CHECKLIST
Wisconsin Uniform Dwelling Code
WIScheck Software Version 1.0 Release 3
DATE: 4-11-2003
Bldg.
Dept.
Use
[ ]
[ ]
CEILINGS:
1. R-38
Comments/Location
WALLS:
1. Wood Frame, 16" O.C., R-t3 + R-3.7
Comments/Location
[ ]
[ ]
[ ]
WINDOWS AND GLASS DOORS:
1. U-value: 0.35
Windows must be labeled and rated in accordance with NFRC or
muse use default values from COMM Table 22.05-1.
For windows without labeled U-values, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments/Location
DOORS:
1. U-value: 0.25
Doors must be labeled and rated in accordance with NFRC or
must use default values from COMM Table 22.05-2.
Comments/Location
FLOORS:
i. Over Unconditioned Space, R-19
Comments/Location
[ ]
[ ]
[ ]
CRAWL SPACE WALLS:
1. Concrete 56" bt/ 48" bg/ 48" insul., R-5
Comments/Location
Applies to walls of unventilated crawl spaces.
HVAC EQUIPMENT:
1. Furnace, 90.0 AFUE or higher
Make and Model Number
AIR LEAKAGE:
Joints, penetrations, and all other such openings in the building
envelope that are sources of air leakage must be sealed.
[ ]
Recessed lights must be type IC rated and installed with no
penetrations or installed inside an appropriate air-tight assembly
(COMI~4 22.32).
VENTILATION:
Mechanical ventilation systems must be balanced. Intake air ducts
must be sized to provide a minimum of 40% of the total air that
TITLE: ADDITION
[ ]
[ ]
[ ]
[ ]
[ ]
would be exhausted with all exhaust ventilation in the dwelling
acting simultaneously (COMM 23.02(3)).
VAPOR RETARDER:
Required on the warm-in-winter side of all non-vented framed
ceilings, walls, and floors.
MATERIALS IDENTIFICATION:
Materials and equipment must be identified so that compliance can
be determined. Manufacturer manuals for all installed heating
and cooling equipment and service water heating equipment must be
provided. Insulation R-values, glazing U-values, and heating
equipment efficiency must be clearly marked on the building plans
or specifications.
DUCT INSULATION:
Ducts in unconditioned spaces must be insulated to a minimum of R-5
(COMM 22.17).
TEMPERATURE CONTROLS:
Thermostats are required for each separate HVAC system. A manual or
automatic means to partially restrict or shut off the heating and/or
cooling input to each zone or floor shall be provided (COMM 22.15).
HUMIDITY CONTROL:
A humidistat is required when humidifying or dehumidifying (COMM 22.16).
[ ~
PIPE INSULATION:
All heating pipes in unheated spaces and all cooling pipes in
uncooted spaces must be insulated with a material providing
a minimum thermal resistivity of R-4 (COMM 22.19).
.... NOTES TO FIELD (Building Department Use Only)
I-t0 u~ e_.
i_. ¢.~ ~c
!
I//q " I 0
an~ acceptable plan drawing. With tim.local ins
Ibis drawing may be detailed by a designer and submitted as part of a
for plan review. (Fa - Fiber bending stress of selected lumber.
species information may bc noted.)
SLOPE:
qG:
RIDGE BOARD
- TIES
AFTERS/TRUSSES:
CtlUTES: ~
PROT:
COVERING:
SHEATilING:
VENEER:
PLATE: _,.~- ~( (~
COURSE:
FDTN. INSUL:
INSUL. PROT:
FDTN..TYPE:
FDTN. THICKNESS
BACKFILL:
DRAIN TILES:
BLEEDERS:
- CEILING FINISH
- VAPOR BARRIER
- INSULATION
- JOISTS
- WALL FRAMING
- INSULATION
__ - VAPOR BARRIER
- INT. WALL FINISH
- BEAM
FINISH FLOOR
FLOOR DECK
JOISTS
CEILING HT:
-COLUMN
'-.o"'t.,.; -
FDTN. liT:
FLOOR
BASE COIJRSE
FOOTING