Loading...
HomeMy WebLinkAbout0100773-BuildingOSHKOSH ON THE WATER .lob ,Address 1742 W 5TH AVE Designer CITY OF OSHKOSH BUILDING PERMIT - APPLICATION AND RECORD Owner GREGORY P WEITZ/GAIL PERDUE Contractor OWNER Category 111 - Single Family Addition No 0100773 Create Date 04/11/2003 Plan Type I(~ Building (~ Sign (~ Canopy (~ Fence ~ Raze Zoning Class of Const: Size Unfinished/Basement 0 Sq. Ft. Rooms 0 Height 0 Ft. ~J Projection Finished/Living 0 Sq. Ft. Bedrooms 0 Stories Canopies Garage 0 Sq. Ft. Baths 0 Signs Foundation O Poured Concrete (~ Floating Slab (~ Pier (~ Other (~ Concrete Block (~ Post (~ Treated Wood Occupancy Permit Flood Plain Height Permit Park Dedication # Dwelling Units 0 # Structures 0 Use/Nature SFR/ Single family addition 32' x 10' (dinette and bathroom). All work shall comply with all building codes. SEPERATE PERMITS REQUIRED of Work FOR ELECTRIC, PLUMBING, AND HVAC. HVAC Contractor OWNER Electric Contractor HOMEOWNER Fees: Valuation $8,800.00 Plan Approval Issued By: Plumbing Contractor HOMEOWNER $0.00 Permit Fee Paid $80.00 Park Dedication $0.00 Date 04/11/2003 Final/O.P. 00/00/0000 Permit Voided In the performance of this work I agree to perform all work pursuant to rules governing the described construction. Signature Date Agent/Owner OSHKOSH Address 1742 W 5TH AVE WI 54902 - 0000 Telephone Number 233-9157 OSHKOSH ON THE WATER Job Address 1742 W 5TH AVE CITY OF OSHKOSH BUILDING PERMIT -APPLICATION AND RECORD Owner GREGORY P WEITZ/GAIL PERDUE Designer Contractor OWNER Category 111 - Single Family Addition Type · Building O Sign (~ Canopy O Fence O Raze No 0100773 Create Date 04/11/2003 Plan Zoning Class of Const: Unfinished/Basement 0 Sq. Ft. Rooms 0 Height 0 Ft. Finished/Living 0 Sq. Ft. Bedrooms 0 Stories Garage 0 Sq. Ft. Baths 0 Foundation · Poured Concrete O Floating Slab O Pier O Other (~ Concrete Block (~ Post (~ Treated Wood Occupancy Permit Flood Plain Height Permit Park Dedication # Dwelling Units 0 # Structures Size [] Projection Canopies Signs Use/Nature SFPJ Single family addition 32' x 10' (dinette and bathroom). All work shall comply with all building codes. SEPERATE PERMITS of Work REQUIRED FOR ELECTRIC, PLUMBING, AND HVAC. HVAC Contractor OWNER Electric Contractor HOMEOWNER Fees: Valuation $6,800.00 Issued By: ~ Plumbing Contractor HOMEOWNER Plan Approval $0.00 Permit Fee Paid [] Permit Voided r $60.00 Park Dedication $0.00 Date 04/11/2003 Final/O.P. 00/00/0000 In the performance of this work I agree ,~o perform all work pursuant to rules governing the described construction. Signature )~ ,~"~/~/~ Date Agent/Owner Address 1742W 5TH AVE OSHKOSH WI 54902 - 0000 Telephone Number 233-9157 WIScheck COMPLIANCE REPORT Wisconsin Uniform Dwelling Code WIScheck Software Version 1.0 Release 3 TITLE: ADDITION COUNTY: Winnebago HEATING TYPE: Non-Electric DATE: 4-11-2003 DATE OF PLANS: 4-11-03 PROJECT INFORMATION: MATT HOLLIS Permit Checked by/Date UDC COMPLIANCE: Passes Code-Allowed UA = 86 Your Home = 85 1.2% Better Than Code Area or Cavity Cont. Glazing/Door Perimeter R-Value R-Value U-Value UA CEILINGS 306 38.0 0.0 WALLS: Wood Frame, 16" O.C. 302 13.0 3.7 GLAZING: Windows or Doors, Above Grade 40 DOORS 18 FLOORS: Over Unconditioned Space 306 19.0 3.7 CRAWL: Concrete 56" bt/ 48" bg/ 48" insul. 208 HVAC EQUIPMENT: Furnace, 90.0 AFUE 0.350 0.250 5.0 9 21 14 5 12 24 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the requirements of the Wisconsin Uniform Dwelling Code. Builder/Designer Date TITLE: ADDITION HEATING EQUIPMENT SIZING S~DMMARY General Information: Outdoor Design Temperature: Conditioned Floor Area: Average Ceiling Height: Infiltration,Rate: Equipment Oversizing Factor: Loads SuInmary: Conductive Losses: Infiltration Losses: Oversizing Factor Losses: -15 deg 306 ft2 8.0 ft 0.50 Normalized ACH 15.0% 7207 Btu/hr 1873 Btu/hr 1362 Btu/hr Total Building Heating Load: 10442 Btu/hr TITLE: ADDITION WIScheck INSPECTION CHECKLIST Wisconsin Uniform Dwelling Code WIScheck Software Version 1.0 Release 3 DATE: 4-11-2003 Bldg. Dept. Use [ ] [ ] CEILINGS: 1. R-38 Comments/Location WALLS: 1. Wood Frame, 16" O.C., R-t3 + R-3.7 Comments/Location [ ] [ ] [ ] WINDOWS AND GLASS DOORS: 1. U-value: 0.35 Windows must be labeled and rated in accordance with NFRC or muse use default values from COMM Table 22.05-1. For windows without labeled U-values, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments/Location DOORS: 1. U-value: 0.25 Doors must be labeled and rated in accordance with NFRC or must use default values from COMM Table 22.05-2. Comments/Location FLOORS: i. Over Unconditioned Space, R-19 Comments/Location [ ] [ ] [ ] CRAWL SPACE WALLS: 1. Concrete 56" bt/ 48" bg/ 48" insul., R-5 Comments/Location Applies to walls of unventilated crawl spaces. HVAC EQUIPMENT: 1. Furnace, 90.0 AFUE or higher Make and Model Number AIR LEAKAGE: Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be type IC rated and installed with no penetrations or installed inside an appropriate air-tight assembly (COMI~4 22.32). VENTILATION: Mechanical ventilation systems must be balanced. Intake air ducts must be sized to provide a minimum of 40% of the total air that TITLE: ADDITION [ ] [ ] [ ] [ ] [ ] would be exhausted with all exhaust ventilation in the dwelling acting simultaneously (COMM 23.02(3)). VAPOR RETARDER: Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors. MATERIALS IDENTIFICATION: Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R-values, glazing U-values, and heating equipment efficiency must be clearly marked on the building plans or specifications. DUCT INSULATION: Ducts in unconditioned spaces must be insulated to a minimum of R-5 (COMM 22.17). TEMPERATURE CONTROLS: Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided (COMM 22.15). HUMIDITY CONTROL: A humidistat is required when humidifying or dehumidifying (COMM 22.16). [ ~ PIPE INSULATION: All heating pipes in unheated spaces and all cooling pipes in uncooted spaces must be insulated with a material providing a minimum thermal resistivity of R-4 (COMM 22.19). .... NOTES TO FIELD (Building Department Use Only) I-t0 u~ e_. i_. ¢.~ ~c ! I//q " I 0 an~ acceptable plan drawing. With tim.local ins Ibis drawing may be detailed by a designer and submitted as part of a for plan review. (Fa - Fiber bending stress of selected lumber. species information may bc noted.) SLOPE: qG: RIDGE BOARD - TIES AFTERS/TRUSSES: CtlUTES: ~ PROT: COVERING: SHEATilING: VENEER: PLATE: _,.~- ~( (~ COURSE: FDTN. INSUL: INSUL. PROT: FDTN..TYPE: FDTN. THICKNESS BACKFILL: DRAIN TILES: BLEEDERS: - CEILING FINISH - VAPOR BARRIER - INSULATION - JOISTS - WALL FRAMING - INSULATION __ - VAPOR BARRIER - INT. WALL FINISH - BEAM FINISH FLOOR FLOOR DECK JOISTS CEILING HT: -COLUMN '-.o"'t.,.; - FDTN. liT: FLOOR BASE COIJRSE FOOTING