HomeMy WebLinkAbout08275 (6/13/03)-Housing violations
Address verification photo
only
No violation in photo
Violation(s) of 16-35A (6) & 16-35A (3)
Cracked/damaged/leaking fixtures or other
plumbing conditions, which create un-
sanitary conditions shall be
replaced/repaired by a licensed plumber
with permit.
Plumbing leak from second floor
Taken by Bruce LuedtkeTaken by Bruce Luedtke
JUNE 12, 2003 1 1 JUNE 12, 2003 1 1
Stairways in two family dwellings
shall be equipped with proper handrails
& guardrails installed in accordance
with COMM 21.04
Includes basement steps
Intermediate rails
required
Violation(s) of 16-33A (6) & 16-34A (3)a
All living units shall be provided with safe and
adequate electrical facilities , fixtures & wiring.
Taken by Bruce LuedtkeTaken by Bruce Luedtke
JUNE 12, 2003 1 2 JUNE 12, 2003 1 2
Installation of a new electric water heater
requires a permit, licensed plumber and
licensed electrician
Violation(s) of 20-8A, SS145.06 & 16-34A (3)a
No permit on file for
this 1999 waterheater
Taken by Bruce LuedtkeTaken by Bruce Luedtke
JUNE 12, 2003 1 3 JUNE 12, 2003 1 3
Wiring of an electric
waterheater requires
a licensed electrician
Violation(s) of 16-34A (3)a
Taken by Bruce LuedtkeTaken by Bruce Luedtke
JUNE 12, 2003 1 4 JUNE 12, 2003 1 4
All living units shall be provided with safe and adequate electrical
facilities , fixtures & wiring. Adequate numbers of electrical
receptacles are required to prevent extension cord use.
Violation(s) of 16-34A (3)a
Taken by Bruce LuedtkeTaken by Bruce Luedtke
JUNE 12, 2003 1 5 JUNE 12, 2003 1 5
Waterheater venting to be
properly installed.
CO HAZARD
Violation(s) of 16-35A (4)
Taken by Bruce LuedtkeTaken by Bruce Luedtke
JUNE 12, 2003 1 6 JUNE 12, 2003 1 6
All living units shall be provided with safe and adequate
electrical facilities , fixtures & wiring. Adequate numbers of
electrical receptacles are required to prevent extension cord use.
Violation(s) of 16-34A (3)a
Taken by Bruce LuedtkeTaken by Bruce Luedtke
JUNE 12, 2003 1 7 JUNE 12, 2003 1 7
All dwelling units, vacant or occupied, shall be provided with working,
approved smoke detectors one each in the basement first and second
floors. Common area smoke detectors (basements) are the sole
responsibility of the property owner. The owner shall
.
replace batteries once per year or at the beginning of new tenanciesWritten
responsibilities shall be given to the occupants concerning smoke detectors.
No smoke detector found in the basement
Violation(s) of 16-33A (7)
Smoke detectors not to be installed
in the kitchen
Taken by Bruce LuedtkeTaken by Bruce Luedtke
JUNE 12, 2003 1 8 JUNE 12, 2003 1 8
All windows in rental dwellings shall be
capable of being opened and closed easily and
remain open without the use of props.
Windows shall be free of chipped, peeling
paint, loose or missing glazing compound,
broken panes of glass and be weather tight.
Violation(s) of 16-35A (1)c
Potential lead hazard
Taken by Bruce LuedtkeTaken by Bruce Luedtke
JUNE 12, 2003 1 9 JUNE 12, 2003 1 9
All windows in rental
dwellings shall be capable of
being opened and closed easily
and remain open without the
use of props. Windows shall
be free of chipped, peeling
paint, loose or missing glazing
compound, broken panes of
glass and be weather tight.
Violation(s) of 16-35A (1)c
Plumbing
permit?
Taken by Bruce LuedtkeTaken by Bruce Luedtke
JUNE 12, 2003 1 10 JUNE 12, 2003 1 10
All windows in rental
dwellings shall be capable
of being opened and
closed easily and remain
open without the use of
props. Windows shall be
free of chipped, peeling
paint, loose or missing
glazing compound, broken
panes of glass and be
weather tight.
Violation (s) of 16-35A (1)c
Taken by Bruce LuedtkeTaken by Bruce Luedtke
JUNE 12, 2003 1 11 JUNE 12, 2003 1 11
All windows in rental dwellings shall be capable of being opened
and closed easily and remain open without the use of props.
Windows shall be free of chipped, peeling paint, loose or missing
glazing compound, broken panes of glass and be weather tight.
Violation(s) of 16-35A (1)c & 16-33A (6)
Stairways in
single family
dwellings shall
be equipped with
proper handrails
& guardrails
installed in
accordance with
COMM 21.04
Taken by Bruce LuedtkeTaken by Bruce Luedtke
JUNE 12, 2003 1 12 JUNE 12, 2003 1 12
Three foot
platform
required or
removal of
the door
Violation(s) of 16-33A (6) & 17-36A
The exterior of every structure including chimneys shall be maintained by the
owner in good repair and all exterior surfaces thereof be kept painted or
covered with exterior siding for purposes of preservation and appearance.
Taken by Bruce LuedtkeTaken by Bruce Luedtke
JUNE 12, 2003 1 13 JUNE 12, 2003 1 13