HomeMy WebLinkAbout2011-Building, HVAC & Lighting #R3-3269-0411 City of Oshkosh
Division of Inspection Services
215 Church Avenue
PO Box 1130
Oshkosh WI 54903 -1130
OJHKOIH www.ci.oshkosh.wi.us
ON THE WATER
May 2, 2011
Coutland Morgan Bruce Williams
Courtland Morgan, Architect Sketches, USA
711 N Fielder Rd 325 S Sepulveda Blvd
Arlington, TX 76012 Manhattan Beach, CA 90266
Dave Spring
Horizon Properties
5000 Hakes Drive •
Muskegon, MI, 49441
Site: Plan Number: R3- 3269 -0411
Skechers
3001 S Washburn St. Space E -70
Oshkosh WI 54904
For:
Description: Tenant space alterations
Object Type: Building and HVAC and Lighting
Class of Construction: IIB - 3000 Sq Ft.; sprinklered
Occupancy: M: Mercantile / Retail
Maximum No of Occupants: 85
The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and
Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in Chapter
101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements
Key Item(s) / Conditions:
• IBC 901.2 Fire protection systems shall be installed, repaired, operated and maintained in accordance with this
code and the international fire code. Construction of new walls may require the addition and or relocation of
sprinkler heads to maintain required coverage, and not obstruct spray patterns of fire sprinklers.
• IBC 1011 Exit signs are required to be installed per this section
• IBC 1006.1 Means of egress illumination is required to be installed per this section
• IBC 1006.3 Means of egress illumination is required to be installed per this section. All paths of egress are required
to have adequate emergency lighting to meet the performance requirements of IBC 1006.4. Existing means of
egress emergency lighting is permitted to be maintained in compliance with the code in effect at the time of
construction. Any altered path of egress or new path of egress, and any new emergency lighting being installed is
required to comply with current code requirements.
• IBC 2902.4 Required public toilet facilities. Customers, patrons and visitors shall be provided with public toilet
facilities in structures and tenant spaces intended for public utilization. Provide signage in mercantile area
indicating direction to toilet rooms.
1
page 1 of 3
•
• IBC 2902.1 Minimum number of fixtures. Plumbing fixtures shall be provided for the type of occupancy and in
the minimum number show in Table 2902.1. A service sink is required to be provided. Provide revised plan
detailing area sink will be provided
• IBC 2902.1 Minimum number of fixtures. Plumbing fixtures shall be provided for the type of occupancy and in
the minimum number show in Table 2902.1. Drinking water is required to be provided — this is permitted to be
bottled water dispenser, or drinking fountain.
• Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve rules under
this code and which are made to construction documents that have previously been granted approval by the
department or its authorized representative, shall be submitted to the office that granted the approval. All revisions
and modifications to plans shall be approved in writing by the department or its authorized representative prior to the
work involved in the revision or modification being carried out. A revision or modification to a plan, drawing or
specification shall be signed and sealed in accordance with Comm 61.31(1).
• MUN 30 This review does not include review for signage. Applications for and questions regarding signage
permits should be directed to Todd Muehrer — Zoning Administrator (920) 236 -5057.
SUBMIT:
• IBC 1006.3 Means of egress illumination is required to be installed per this section. All paths of egress are
required to have adequate emergency lighting to meet the performance requirements of IBC 1006.4. Provide
complete emergency lighting plan showing compliance with these requirements prior to installation of
emergency lighting system. — Photometric plans were not included in plan submittal. A copy of the City of
Oshkosh Policy on Emergency Lighting is attached to this letter.
• IBC 2902 Table 2902.1 Minimum Number of Plumbing Facilities. A minimum of one service sink is required to
be provided. IMC 403.3 [Comm 64.0403 (6)] Ventilation rate. Janitor closets. A janitor closet that has only one
service sink may be provided with either natural ventilation via a window or louvered opening with at least 2 square
feet (0.2 m2) of area openable directly to the outside or mechanical exhaust ventilation as specified in Table
64.0403. Plans submitted do not show the required service sink included in building plans. The IMC requires
ventilation of the space containing the service sink. Provide additional details /floor plan showing where the
required service sink will be located and how required ventilation will be provided.
• IMC 403.3.4 Balancing. Ventilation systems shall be balanced by an approved method. Such balancing shall
verify that the ventilation system is capable of supplying the airflow rates required by Section 403. Balancing
report required to be submitted prior to final occupancy being allowed.
• Comm 61.40 (4) Supervision. Prior to the initial occupancy of a new building or addition and prior to the final
occupancy of an alteration of an existing building the supervising professional shall file a compliance statement
form SBD -9720 with this office. Note: Submittal of a compliance statement will be considered as evidence that
the supervising professional has properly addressed all items identified in this plan review letter.
A copy of the approved plans, specifications, and this letter shall be on -site during construction. If plan index sheets were
submitted in lieu of additional full plan sets, a copy of this approval letter and index sheet shall be attached to plans that
correspond with the copy on file with the copy on file in this office.
All permits are required to be obtained prior to commencement of work.
a,;F ,s
page 2 of 3
In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or
additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this
review shall relieve the designer of the responsibility for designing a safe building, structure, or component. The City of
Oshkosh does not take responsibility for the design or construction of the reviewed items.
Inquiries concerning this correspondence may be made to me at the number listed below or the address on this letterhead.
Resp
Brian oe
Building Systems Consultant
(920) 236 -5051
bnoe@ci.oshkosh.wi.us
cc: Property file Fee Required $ 600.00
Fee Received $ 720.00
Refund Due $ 120 00
Being processed
page 3 of 3