HomeMy WebLinkAbout9784-Electric (12/20/2004) INSPECTION SERVICES DIVISION ROOM 205 CITY OF OSHKOSH DEPARTMENT OF COMMUNITY DEVELOPMENT 215 CHURCH AVE OSHKOSH CORRECTION NOTICE PO Box 1130 OSHKOSH WI 54903 -1130 ON THE WATER Issue Date 12/20/04 Compliance Date 1/19/05 IMMEDIATELY Compliance No Address 3465 MOSER ST Name Address City State Zip Code Sent to u Owner GNC OSHKOSH LLC 3465 MOSER ST OSHKOSH WI 54901 -0000 j Required for Occupancy Occupancy Industrial Introduction While conducting a routine electrical inspection the following violations were noted and reviewed with Mike OIk from Buss Electric. I told Mike that if the violations were corrected within 30 days, I would not issue a correction notice. Item # 1 Code NEC 110.16 Compliance No Compliance Date 01/19/2005 IMMEDIATELY Description Electrical equipment that is likely to require examination, adjustment, servicing, or maintenance shall be marked with field installed "Arc Flash Warning Labels" 12/20/04 Last Updated Item # 2 Code NEC 210.4 Compliance No Compliance Date 01/19/2005 IMMEDIATELY Description When more than one nominal voltage system exists in a building each ungrounded conductor shall be identified and that identification shall be permanently posted at each branch circuit panelboard. 12/20/04 Last Updated Item # 3 Code NEC 110.14 Compliance No Compliance Date 01/19/2005 IMMEDIATELY Description Parallel terminations shall be made with terminals listed for the pupose (grounding) 12/20/04 Last Updated Item # 4 Code NEC 250.8 Compliance No Compliance Date 01/19/2005 IMMEDIATELY Description Sheet metal style screws shall not be used to connect grounding conductors to enclosures 12/20/04 Last Updated Item # 5 Code NEC 250.97 Compliance No Compliance Date 01/19/2005 IMMEDIATELY Description For circuits over 250V to ground, the electical continuity of metal raceways shall be ensured when concentric k.o.'s are used. 12/20/04 Last Updated Item # 6 Code NEC 250.4 Compliance No Compliance Date 01/19/2005 IMMEDIATELY Description Electrically conductive materials that are likely to become energized shall be connected together and to the electric supply source in such a manner that establishes an effective ground path. (equipment grounds in the MCC's shall be connected to the 12/21/04 enclosure) Last Updated 9784 Page 1 of 3 �� INSPECTION SERVICES DIVISION ROOM 205 CITY OF OSHKOSH [/ . DEPARTMENT OF COMMUNITY DEVELOPMENT 215 CHURCH AVE OSHKOSH CORRECTION NOTICE PO Box 1130 ON THE WATER OSHKOSH WI 54903 -1130 Issue Date 12/20/04 Compliance Date 1/19/05 IMMEDIATELY Compliance No Address 3465 MOSER ST Name Address City State Zip Code Sent to u Owner GNC OSHKOSH LLC 3465 MOSER ST OSHKOSH WI 54901 -0000 Introduction u Required for Occupancy Occupancy Industrial While conducting a routine electrical inspection the following violations were noted and reviewed with Mike OIk from Buss Electric. I told Mike that if the violations were corrected within 30 days, I would not issue a correction notice. Item # 7 Code NEC 314.17 Compliance No Compliance Date 01/19/2005 IMMEDIATELY Description Where the Tray Cable enters a metallic enclosure the cable shall be be installed per NEC 314.7 (A), (B) &(D). (fittings are required) 12/21/04 Last Updated 9784 Page 2 of 3 INSPECTION SERVICES DIVISION ROOM 205 CITY OF OSHKOSH DEPARTMENT OF COMMUNITY DEVELOPMENT 215 CHURCH AVE OSHKOSH CORRECTION NOTICE PO Box 1130 ON THE WATER OSHKOSH WI 54903 -1130 Issue Date 12/20/04 Compliance Date 1/19/05 IMMEDIATELY Compliance No Address 3465 MOSER ST Name Address City State Zip Code Sent to u Owner GNC OSHKOSH LLC 3465 MOSER ST OSHKOSH WI 54901 - 0000 Introduction u Required for Occupancy Occupancy Industrial While conducting a routine electrical inspection the following violations were noted and reviewed with Mike Olk from Buss Electric. I told Mike that if the violations were corrected within 30 days, I would not issue a correction notice. Item # 8 Code COMM 16.11 Compliance No Compliance Date 01/19/2005 IMMEDIATELY Description Materials, equipment and products which do not comply with the requirements of this chapter shall not be used unless approved in writing by the Department of Commerce Safety & Buildings or by a qualified independent third party. (Electrical 12/20/04 machinery, controls, motor control centers, etc.) This was discussed with the electrician on 8/3/04. Last Updated Summary To avoid any further inconvenience please correct the above noted violations immediately. Any questions or concems please feel free to contact me at 920 - 236 -5046. Violations must be corrected and approved within 30 days unless otherwise noted. Call for reinspections prior to concealment and /or occupancy. Upon completing the corrections, the owner /contractor /agent must sign and date at the bottom of this notice and return it to the Inspection Services Division by the Compliance Date of 1/19/05 Office hours for obtaining permits are Monday through Friday 7:30 -8:30 a.m. and 12:30 -1:30 p.m. or by appointment. To schedule inspections please call the Inspection Request line at 236 -5128 noting the address, permit number (when applicable), and the nature of what needs to be inspected. Signature Date / ap-1/6 9 Aka Ins •''ggr : Kevin Benner 236 -5046 kbenner@ci.oshkosh.wi.us I hereby certify the violations listed on this report have been corrected in compliance with the applicable codes. Print Name Company Signature Date Also Sent to: a Bldg • Elec BUSS ELECTRIC INC W6166 GREENVILLE DR GREENVILLE WI 54942 -9676 u HVAC - • Plbg _ ▪ Designer ✓j Other OCCUPANT 3465 MOSER ST OSHKOSH WI 54901 -0000 _J Inspector 9784 Page 3 of 3