Loading...
HomeMy WebLinkAbout0145500-Building (relocation of tank pad) CITY OF OSHKOSH No 145500 OSHKOSH BUILDING PERMIT - APPLICATION AND RECORD ON THE WATER Job Address 2541 W 20TH AVE Owner PEPSI COLA BOTTLING CO OSHKOSH Create Date 04/08/2011 Designer Contractor CHA TECH SERVICES Category 211 - Alteration Industrial Plan S3- 3256 -0411 Type • Building 0 Sign 0 Canopy O Fence 0 Raze Zoning Class of Const: Size Unfinished /Basement Sq. Ft. Rooms Height Ft. ❑ Projection I Finished /Living Sq. Ft. Bedrooms Stories Canopies Garage Sq. Ft. Baths Signs Foundation • Poured Concrete 0 Floating Slab 0 Pier O Other O Concrete Block O Post 0 Treated Wood Occupancy Permit Not Required Occupancy Fee $0.00 Flood Plain No Height Permit Not Required Park Dedication Not Required # Dwelling Units 0 # Structures 0 Use /Nature IND/ Relocation of CO2 / Nitrogen tank pad 11' x 22' x 2 -6" deep as per plans located on existing asphalt area. of Work HVAC Contractor Plumbing Contractor Electric Contractor Fees: Valuation $9,000.00 Plan Approval $0.00 Permit Fee Paid $81.00 Park Dedication $0.00 Issued By: Date 04/18/2011 Final /O.P. 00 /00 /0000 ❑ Permit Voided Parcel Id # 1328580000 In the performance of this work I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit appli : ion within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure an = essary approval .- or- std ng such activity. I have read and underst- • / - for - pentioned i .rma Signature ' �' Date `�"� a /�� Agent/Owner Address 270 PEACHTREE ST NW, STE 1500 ATLANTA GA 30303 - 0000 Telephone Number (678) 954 -5000 To schedule inspections please call the Inspection Request line at 236 -5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. City of Oshkosh Inspection Services Division P O Box 1130 • Oshkosh, WI 54903-1130 Phone: (920) 236 -5050 Fax: (920) 236-5084 Building Permit Application �� If you are a contractor participating in the Permit Fee Account System and have adequate funds, check here if you want this processed through vour• account (l JOB ADDRESS f 1,3 1 ' Ave, asi-Vcost4 OWNER E+E+'tAgf6S L+E i s+t7i‘y CONTRACTOR - Tr-e-44 Ill �L I am the: 0 Owner OR 1.1i( Contractor USE CATEGORY ❑Single Family ❑Duplex ❑Multi- Family ❑Rental ( Commercial ❑industrial Work being done: Addition i - _s Deck /Porch /Patio E Driveway/Parking .i External Remodeling [1 Fence/Hedge/Kennel :1 Garage/1}tility Structure E:: Handicap Ramp ;:::Hot Tub /Spa Internal Remodeling Sign/Canopy /Awning Stair /Handrail Stove /Fireplace 0 Swimming Pool 0 Wrecking Permit Other 2 / I 7 K eize- ovdt4. For Extemai Remodeling, Wrecking Permit, and Internal Remodeling please see Chapter NR 447 of the Wisconsin Administrative Code and Notification Form 4500 -113 on the DNR Asbestos Program website; htto : /ldnr.wi.gov /air /compenf3 /asbestos;. For additional information on hazards present in buildings see the Pre - Demolition Environmental Checklist at NU) : Ifdnr. wi. caovtora/ awdwm /oubiications /anewcubANA651.pdf Additional information, such as plan submittal and approval, may be required before issuance. Fliers, located in the hallway, may be referenced to note if any additional information is necessary. • Full description of work being done: Re e m9461 dog &segriAke Atlfrizoifoitrz / //$m4-t._ Ni— ill " K Zi es K Z i r- 1-o erg" 614 S77 Mp . Any work not included in this application is not permitted. Value of the job $ 0. alue for materials and labor is required to ensure consistency in accessing permit fees tbr all applicants.) PLEASE READ, SIGN, & DATE: 1 certify the above information is complete and accurate. Any deviations from the above submitted information may require additional permits to be obtained. I acknowledge and agree to these terms. Name: eAee24 -t 1 - 51411 , ^ �. print) Signature: Date: 1/ /l 3/02 Page 1 of 2 Noe, Brian From: Rabe, James E. Sent: Friday, April 08, 2011 10:52 AM To: Muehrer, Todd M. Cc: Noe, Brian Subject: RE: Revised site plan /tank pad location Ahh, the other "proposed" tank area. Yeah, I have no issues with that location. From: Muehrer, Todd M. Sent: Friday, April 08, 2011 10:51 AM To: Rabe, James E. Cc: Noe, Brian Subject: RE: Revised site plan /tank pad location I think you're looking at the wrong area on the plan. The tank pad is behind /to the south of the building addition... From: Rabe, James E. Sent: Friday, April 08, 2011 10:49 AM To: Muehrer, Todd M.; Noe, Brian Subject: RE: Revised site plan /tank pad location I thought that "tower" was shown on the original plans? I don't see any issues with it. From: Muehrer, Todd M. Sent: Friday, April 08, 2011 8:54 AM To: Noe, Brian; Rabe, James E. Subject: RE: Revised site plan /tank pad location Zoning is approved. That's the location Griese indicated on the phone with me earlier this week also... From: Noe, Brian Sent: Friday, April 08, 2011 8:53 AM To: Rabe, James E.; Muehrer, Todd M. Subject: FW: Revised site plan /tank pad location James and Todd, This is the site plan for the tank pad -- let me know if you are o.k. with permits being issued. Thanks - Brian From: Skarphol, Charles [ mailto :CSkarphol ©chatechservices.com] Sent: Friday, April 08, 2011 8:39 AM To: Noe, Brian 4/8/2011 Page 2 of 2 Cc: Hunter, Scott; Springthorpe, Paul; Dwyer, Timothy Subject: Revised site plan /tank pad location Brian Please find attached the site plan showing the new tank pad location. There is no change in the drainage or impervious surface with this relocation. Any question please call me 404 387 9067 Thanks for your help Charlie Skarphol 4/8/2011 Page 1 of 1 Noe, Brian From: Skarphol, Charles [CSkarphol @chatechservices.com] Sent: Friday, April 08, 2011 8:39 AM To: Noe, Brian Cc: Hunter, Scott; Springthorpe, Paul; Dwyer, Timothy Subject: Revised site plan /tank pad location Attachments: EX -A 30X42.pdf Brian Please find attached the site plan showing the new tank pad location. There is no change in the drainage or impervious surface with this relocation. Any question please call me 404 387 9067 Thanks for your help Charlie Skarphol 4/8/2011 ri' ctwcuc�rs ..o ttnws4xwlar mw,rvrslos.emrla' -ao.c ^^'-- __— ,.__.. _— __— �.___. __ - -� -- — ..._�..__�O __r.S89'Ifi43' - - --. — `I II i a Ct� u .r g 2i _ TAX NO. IS 958 -Op STOP 1 _ _ sp ry 3 . f f f V / f I coHCPerE n IN ASPHALT � 1 a ASPHALT ii t CONCRETE m — I A ASPHALT CONCRETE \CONCRETE s � f E I ' 1 'b a2 �l TREES � �5g g O I k Llue i - a I j � I PEPSI Bo CDI�AN1f CA-Mr--- a RELOCATED TANK PAD EXHIBIT ... m• PBC Page 1 of 1 Noe, Brian From: Skarphol, Charles [CSkarphol @chatechservices.com] Sent: Wednesday, April 06, 2011 4:55 PM To: Noe, Brian Cc: Hunter, Scott Subject: Oshkosh Pepsi Blow Mold Room Addition /relocated Tank Pad Attachments: CCF04062011_00000.jpg; CCF04062011_00001.jpg; Pad Install Procedure.pdf; PBC Oshkosh WI Layout.pdf; OSH_Tank Pad.pdf Hello Brian I have attached the completed Building Permit Application for the addition and relocated Tank Pad with site plan for your review. If you could get me the fee for these two permits I will bring a check along with me Monday and drip off by 10:30 AM Monday. Any questions please call me on my cell 404 387 9067.FYI Option #1 on the Tomco plan is what we are using. Thanks for your time today and looking forward working with you on this great project. Charlie Skarphol Project Manage /Site Superintendent 4/8/2011 t \ t 3 1 314 "x314" Chamfer or Tooled Edge Transport Pad Typical All Around At Drive Grade Tank Pad (Level) m 3" Clear Typical Typical Section Through Pads Chem Sea[ CS 2727 Sealant By Neely Industries 1 -800- 242 -1483 Other Sealants Not Permitted 112" 112" Polyfoam Board (Use of Asphalt Impregnated Board is Prohibited.) 2 Reinforcin Clearance Typical Joint For Oxygen Service Pad Installation Procedure See Typical Joint Detail Vaporizer Pad (Level) •A r Finish Grade 4" Compacted Crushed Stone Firm Subgrade High Performance Polyurethane Sealant Sikaflex 1a or Other Approved 112" 112" Polyfoam Board N r 2" Reinforcin Clearance Typical Joint For Nitrogen or Argon Service 1. Site must be well drained and have sufficient soil bearing pressure to support the floating pads. 2000 pounds per square foot is the minimum recommended soil pressure. 2. Excavate material to the proper elevation to accommodate the pad and base. The bottom of the excavation, or subgrade, must be firm and free of water. Make sure that the excavation has a path for the water to escape. Water must not be allowed to be trapped under the pads. If the bottom of the excavation does not meet these specifications, the pads cannot be installed until corrective action has been taken. 3. Place aggregate base material in the excavation. The best material for the base is a clean, well graded crushed stone ranging from 1" to dust. Compact this material uniformly with a vibrating plate or vibrating roller. The surface should feel like concrete when walked on. 4. Install forms with adequate strength and the proper grades. The surfaces of both tank pad and vaporizer pad shall be level. Install forms at the joints. Joints shall be constructed as specified. Install the specified reinforcing bars with three inches (3") of clearance above the aggregate base. Maintain three -inch (3") clearance at edges and two -inch (2 ") clearance from the joints. 5. Pour concrete (4000 psi mix) and screed to the specified grades. After initial set, remove joint forms and install the specified foam backer board prior to making the next pour. Saw cutting is not permitted. Finish the surface of the pads with a light broom finish and finish the edges with a chamfer or radius. 6. After pad has cured for 28 days, caulk the joints with the specified sealant. Follow the manufacturer's instructions explicitly. Issued By Date CONFIDENTIAL NOTICE This document and the designs specifications and engineering information disclosed hereon are the proprietary property of the dirgas company providing it and are not to be disseminated or e Airgas companies a :ipient, this document it express written consent of such Airgas company. This proprietary ;onfidence and only for consideration of the matter hereon. 3 document, recipient agrees to keep it and the matter disclosed hereon use or permit their use in any way detrimental to any Airgas companies ipt no repponsibility for the use of this document by any only for illustrative purposes. ,,S OF O e , y� STANLEY o + M. 24218 0 tiF oc�s NAL Pad Installation Procedure For Industrial 1 Commercial and Healthcar A Facilit Use Date 4/1109 P 1 P 1 RELOCATED CYLINDER FILLING SYSTEM r------- - - - - -- ! 5 � 1 ! � EXISTING NITROGEN TANK EXISTING CO NEW 14 TON VERTICAL CO2 STORAGE UNIT - RELOCATED NITROGEN TANK 10'-0" 1 22' -0" 1 10' -0" TEMPORARY RELOCATED EXISTING CO2TANK (ON CROSSTIES) PLAN VIEW ELEVATION VIEW OPTION #1 NEW 14 TON HORIZONTAL RELOCATED CYLINDER 1021T0RAGE UNIT FILLING SYSTEM RELOCATED NITROGEN TANK --------- -- - - -- r r , � i r � EXISTING NITROGEN TANK PLAN VIEW 10' -0" 1 23' -9" 1 11' -0" 1 10 TEMPORARY RELOCATED EXISTING CO2TANK (ON CROSSTIES) ( r , r , ELEVATION VIEW OPTION #1 NEW 14 TON HORIZONTAL RELOCATED CYLINDER 1021T0RAGE UNIT FILLING SYSTEM RELOCATED NITROGEN TANK --------- -- - - -- r r , � i r � EXISTING NITROGEN TANK PLAN VIEW 10' -0" 1 23' -9" 1 11' -0" 1 10 TEMPORARY RELOCATED EXISTING CO2TANK (ON CROSSTIES) ELEVATION VIEW OPTION #2 EXISTING CO2TANK ( r , ELEVATION VIEW OPTION #2 EXISTING CO2TANK 8 7 6 a�srawLx PEPSI OSHKOSH, wOMPANY R H t C litiz PROJECT Relocated BMSB P F Q f E N 5 t" 1 L � Iii i L1 K1» New Tank Pad for Relocated Tanks 11'x22'x2j' C r i! f f] >a 8 7 6 U 4 3 2 1 DESIGN GROUP a�srawLx PEPSI OSHKOSH, wOMPANY R H Q C PROJECT Relocated BMSB P F Q E N P THIS DRAWNO AND THE t FORVAT10N THEREON ARE THE PROPEHIY OF, AND THE DISCLOSURE OF THIS DRANiNa OR frS INFORLUTON SHALL NOT BE PERMITTED WITHOUT THE PERIJMVON OF, THE BARRY- W'DHMILtER COMPANY OF ST. LOUIS, VMOURI penr!! AWS 9CYL N A v C E a Qdnm JSB CuE: 4/6/2011 t< a r+ma`cr w= tr„- Pxn.:a r.L RiY. {� EV. !C'/SxA� PFSO'��%M! APPPA.41] 6�SE vt.V. R[rGp+ OFSC�Pf�! IPPahF➢ 6�iE 4 3 2 1