Loading...
HomeMy WebLinkAbout0094320-Building CITY OF OSHKOSH No 0094320 OSHKOSH BUILDING PERMIT - APPLICATION AND RECORD ON THE WATER Job Address 1370 MORELAND ST Owner Create Date 04/29/2002 Designer Contractor DEL TRITT CONSTRUCTION Category 110 - New Single Family Plan D1- 063 -0402R Type • Building 0 Sign 0 Canopy 0 Fence 0 Raze Zoning R1 Class of Const: 8 Size IRRG Unfinished /Basement 1306 Sq. Ft. Rooms 6 Height 17 Ft. ❑ Projection Finished /Living 1306 Sq. Ft. Bedrooms 3 Stories 1 Canopies 0 Garage 484 Sq. Ft. Baths 2 Signs 0 Foundation • Poured Concrete 0 Floating Slab 0 Pier 0 Other 0 Concrete Block 0 Post 0 Treated Wood Occupancy Permit Required Flood Plain No Height Permit Not Required Park Dedication Required # Dwelling Units 1 # Structures 1 Use /Nature NSFR/ New single story home with 2 car attached garage and 10 x 12' patio. of Work HVAC Contractor G & B PRODUCTS Plumbing Contractor RASMUSSEN PLUMBING Electric Contractor CUMINGS ELECTRIC Fees: Valuation $89,000.00 Plan Ap.roval $75.00 Permit Fee Paid $347.00 Park Dedication $100.00 Issued By: ` `��' Date 05/14/2002 Final /O.P. 00 /00 /0000 ❑ Permit Voided I In the performance of this work I agree to perform all work pursuant to rules goveming the described construction. Signature Date Agent/Owner Address 6228 COUNTY RD N PICKETT WI 54964 - 9533 Telephone Number 589 -4209 OSHKOSH GRADE STAKE FORM ON THE WATER Grade Stake Number 6727 Name Del Tritt Construction LLC Address 1370 MORELAND ST Create Date 05/02/2002 Lot 4 Block Ward Subdivision Kitty E. Subd. Zone Street Number Lot Dimensions Sidewalk Existing Building Grade Elevation Stakes Set At Site 05/07/2002 Set By mb 578/7 Department of Public Works 1, the undersigned, owner or agent of the above described property agree to h- - , e grade established before excavation has commenced. Wisconsin Department of Industry, WISCONSIN UNIFORM Application No. Labor and Human Relations Safety and Buildings Division BUILDING PERMIT 0094320 P.O. Box 2509 APPLICATION Parcel No. Madison, WI 53701 -2509 Wisconsin Statues 101.63, 101.73 0 Constr ❑ HVAC ❑ Elec ❑ Plbg 0 Erosion ❑ Other: Owner's Name Mailing Address Telephone No. Oshkosh WI 54901 - 0000 Contractor: Q Con❑ Elec❑ HVAC II Plbg Lic/Cert # Mailing Address Telephone No. DEL TRITT CONSTRUCTION 665731 6228 COUNTY RD N PICKETT WI 54964 - 9533 589 -4209 Contractor: . Con 0 Elec U HVAC • Plbg Lic/Cert # Mailing Address Telephone No. CUMINGS ELECTRIC 170792 PO BOX 749 1414 COUNTY RD JJ NEENAH WI 54957 - 749 231 -5946 (Did Contractor: • Con • Elec 0 HVAC • Plbg Lic/Cert # Mailing Address Telephone No. G & B PRODUCTS 12851 1026 S MAIN ST OSHKOSH WI 54902 -6020 (920) 231 -5699 Contractor: Li Con • Elec. HVAC 121 Plbg Lic/Cert # Mailing Address Telephone No. RASMUSSEN PLUMBING 1914 GREENBRIAR TRL OSHKOSH WI 54904 - 8887 920- 233 -6747 Lot Area S.. ft. 1/4, 1 /4,Section ,T N,R E(or)W Building Address Subdivision Name Lot No. Block No. 1370 MORELAND ST Kitty E. Subd. 4 Zoning District(s) Zoning Permit Q No. Front Iiiii=111 Right Q New ❑ Repair 0 Single Family Entrance Panel Q Forced Air Furnace Fuel Nat. LM. Oil Elec. Solid Sola ❑ Alteration Two Family Size: 100 am. ❑ Radiant Baseboard or Panel Ga mil ❑ Raze - _ Garage El Q ❑ Addition Service: Heat Pump Space Htg ❑ ❑ ❑ ❑ El ❑ Gara 9 Move ❑ Other (print): ❑Overhead ❑ Boiler Water Htg 12000 ❑ ❑ g Underground Other ❑ 0 Central Air Conditioning * • Dwelling unit will have 3 kilowatt or � '' � ' - ' � � - . Other more installed electric space heating equip. , Q Site Constructed • Concrete �� r a Infiltration control option is: ❑ Full sealing Unfinished ❑ Manufactured ❑ Masonry Sewer of joints. ❑ Blower door test. ❑ Exterior Basement 1306 Sq. ft. ':„. II Treated Wood 4 � 0 Municipal air infiltration barrier. Living Area 1306 Sq. ft. 12 1 -Story ❑ Other ❑ Septic ❑ 2 -Story ° " Permit No. Envelope 25510 BTU /HR Garage 484 Sq. ft. ❑ Seasonal ❑ Other � � _ "' � Infiltration 16034 BTU /HR Q Permanent Q Municipal Utility r���ed�,e u..,�,'��,�� _ .a_ ❑ Plus Basement ❑ Other ❑ Private On -Site Well $103,000.00 The applicant agrees to comply with 'cable codes, statues and ordinances and with the conditions of this permit, understands that the issuance of the permit creates no legal liability, press r implied on the Department or municipality; and certifies that all the above information is accurate. APPLICANT'S SIGNATUR ( � ��' DATE SIGNED J� — / Qa APPROVAL CONDITIONS This permit is issued pursuant to the following conditions. Failure to comply may result in suspension or revocation of this permit or other penalty See "Standard Conditions of Approval" sheet ❑ Town ❑ Village 0 City ❑ County • State of: Municipality Number of Dwelling Location: City Of Oshkosh 7 0 - 2 6 6 Plan Review $75.00 0 Construction Inspection In HVAC Name John Zarate Electrical Wis. Permit Seal $30.00 Plumbing Date 5/13/02 Other ✓ Erosion Total $105.00 11 270666 Cert. No. 70330 SBD -5823 (R. 07/92) OSHKOSH PARKLAND DEDICATION FEE COLLECTION RECORD ON THE WATER Job Address 1370 MORELAND ST Date 05/14/2002 Name Address Oshkosh WI 54901 Subdivision Kitty E. Subd. Lot 4 Building Permit Number 0094320 Number of Dwelling Units 1 Number of Structures 1 Fee Required $100.00 Fee Paid • Owner's Signature Date . / _ Inspector's Signature Date CITY OF OSHKOSH STANDARD CONDITIONS OF APPROVAL Project Address 137() M 01 e\�Ar\d 5L Permit # 2 Please read the following information and sign at the bottom to acknowledge that you have read and agree to comply with these conditions. 1. All habitable rooms must be provided with 8% light and 3.5% ventilation. Bedrooms located on the second floor or below ground level must be provided with egress windows in addition to the light and ventilation requirements. Basement windows are also required to have window well areas in accordance with ILHR 21.03. 2. Garage spaces shall be separated from the dwelling unit in accordance with ILHR 21.08. The door and frame assembly between the dwelling unit and an attached garage shall be labeled by an independent testing agency as having a minimum fire - resistive rating of 20 minutes. All drywall joints are required to be taped/sealed unless the joints are fitted so that the gap is no more than a dimes thickness ( 1/20 -inch) and backed by solid wood or drywall with the joints staggered. 3. All penetrations in exterior walls must be sealed prior to the insulation inspection. This includes holes in the top and bottom plates, gaps around heating ducts, and holes in the return air spaces. 4. Smoke detectors are required on every floor and within 6' of all bedrooms. The smoke detectors are required to be hardwired and interconnected. 5. Hydromassage tubs are required to have an access panel to motor. The access panel must be accessible without removing the finish of the house. 6. All overframing must be designed by the truss manufacturer, according to standards set by the truss plate institute, or structural calculations must be provided prior to the rough building inspection. 7. Truss plans must be submitted and approved prior to framing the roof. 8. Truss plans including the truss layout must be provided on site at the rough building inspection. In addition to the truss plans, microlam calculations must be provided on site at the rough building inspection for all microlams with point loads on them. 9. Calculations must be provided for all cantilevered floors with point loads. Floor trusses and TJI's must be designed for the cantilevered areas. 10. The property owner and applicant is responsible for compliance with ILHR 21.125 (Erosion Control). When installing access drives, a minimum of 2 " -3" diameter stone is required in addition to a minimum of 6" depth, 30' -50' length, and 14' -20' width. Erosion control measures must be maintained until the lawn is established. 11. All storm sewer inlets must be protected with approved erosion control devices. Tracking (i.e. sediment) must be removed from the street at the end of each workday. Repair any siltation or erosion damage to adjoining surfaces and drainageways resulting from land development or disturbing activities. 12. The building placard must be posted on site at all times. Once the rough framing is up the placard must be posted on the patio door or on a kitchen window. If the placard is not present at any inspection, stop work orders will be posted. Additional placards can be obtained through our department if the cards are misplaced. 13. All mechanicals must be roughed in prior to requesting the rough building inspection. If on the inspection the mechanicals are not roughed in, the inspection will fail and a $100 re- inspection fee will be charged. 14. Attached is a copy of the final inspection checklist. At the final inspection all items on this list must be completed to avoid the $100 re- inspection fee per inspection. 15. When requesting final inspections please note that a minimum of 2 days notice is needed from the time the inspection is ready. Furniture is only allowed to be placed in the center of the garage floor and a minimum of a 3' pathway must be provided around the walls of the garage. At the final inspection no furniture or personal belongings are allowed in the house. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in place due to the electrical inspector needing to look at the power serving the appliances. A 6' stepladder must be on site at the final inspection to provide access to the attic. 16. The building placard must remain on the patio door or on a kitchen window until occupancy is approved. Occupancy is not allowed prior to the placard having all of the final inspection approved stickers on the backside. If occupancy occurs prior to the inspections being approved daily citations will be issued with no further notice being given. 17. All site grading must be done in accordance with the approved drainage plan on file in the public works office, 3rd floor. • S ignature o/ 4ppCicant: �� aUa cS �r` -E. tillsili ..: as .. = o $ N rc t o 11 II III!JPJP N A 2 ' E 4 0. 0 . Za " E c i '08 _ 10 *08 1 6 1 — /0 f-h------ 5 21 C x 1 1 Q fga 1Q IAA �.a. ,, .. A.noe.....,.. 1 32` N I s' , T k 1 ii. )0 • 0 4 EP t ** 0 1'08 ,6. • i