Loading...
HomeMy WebLinkAbout0094777-Building a) CITY OF OSHKOSH No 0094777 OSHKOSH BUILDING PERMIT - APPLICATION AND RECORD ON THE WATER Job Address 2852 MONTCLAIR PL Owner HEARTLAND HOMES CONST. Create Date 05/30/2002 Designer Contractor HEARTLAND HOMES LLC Category 110 - New Single Family Plan D1- 075 -0502R Type • Building 0 Sign 0 Canopy 0 Fence 0 Raze Zoning R -1 Class of Const: 8 Size IRRG Unfinished /Basement 1113 Sq. Ft. Rooms 7 Height 28 Ft. D Projection Finished /Living 2274 Sq. Ft. Bedrooms 3 Stories 2 Canopies 0 Garage 588 Sq. Ft. Baths 3 Signs 0 Foundation • Poured Concrete 0 Floating Slab 0 Pier 0 Other 0 Concrete Block 0 Post 0 Treated Wood Occupancy Permit Required Flood Plain No Height Permit Not Required Park Dedication Required # Dwelling Units 1 # Structures 1 Use /Nature NSFR/ New single family home, 2 car attached garage and 12' x 12' patio. of Work HVAC Contractor CONDON TOTAL COMFORT Plumbing Contractor HANSON QUALITY PLUMBING Electric Contractor CUMINGS ELECTRIC Fees: Valuation $123,000.00 Plan Approval $75.00 Permit Fee Paid $449.00 Park Dedication $100.00 Issued By: Date 05/31/2002 Final /O.P. 00 /00 /0000 ❑ Permit Voided In the performance of this work I e to pe rm all work pursuant to rules governing the described construction. Signature 0 Date L /3 / Q Z 9 A ent/Owner Address 1750 Woods ck St Oshkosh WI 54904 - 0000 Telephone Number 410 -4707 OSHKOSH GRADE STAKE FORM ON THE WATER Grade Stake Number 6741 Name HEARTLAND HOMES CONST. Address 2852 MONTCLAIR PL Create Date 05/30/2002 Lot 45 Block Ward Subdivision 2nd add't. to Fox Chase Zone Street Number Lot Dimensions Sidewalk Existing Building Grade Elevation Stakes Set At Site 05/30/2002 Set By Department of Public Works I, the undersigned, owner or agent of the above described property agree to have the grade estab 'shed b- • re excavation has commenced. -4‘ Wisconsin Department of Industry, WISCONSIN UNIFORM Application No. Labor and Human Relations Safety and Buildings Division BUILDING PERMIT 0094777 P.O. Box 2509 APPLICATION Parcel No. Madison, WI 53701 -2509 Wisconsin Statues 101.63, 101.73 0 Constr ❑ HVAC ❑ Elec ❑ Plbg 0 Erosion ❑ Other: Owner's Name Mailing Address Telephone No. HEARTLAND HOMES CONST. 1750 WOODSTOCK ST Oshkosh WI 54901 - 0000 Contractor: 0 Con❑ Elec[ HVAC • Plbg Lic/Cert # Mailing Address Telephone No. HEARTLAND HOMES LLC 877644 1750 Woodstock St Oshkosh WI 54904 - 0 410 -4707 Contractor: Ill Con 0 Elec U HVAC • Plbg Lic/Cert # Mailing Address Telephone No. CUMINGS ELECTRIC 170792 PO BOX 749 1414 COUNTY RD JJ NEENAH WI 54957 - 749 231 -5946 Contractor: II Con • Elec 0 HVAC II Plbg Lic/Cert # Mailing Address Telephone No. CONDON TOTAL COMFORT 3202 11 BLACKBURN ST RIPON WI 54971 -184 (920) 748 -5050 Contractor: U Con • Elec U HVAC 0 Plbg Lic/Cert # Mailing Address Telephone No. HANSON QUALITY PLUMBING 550 N BLUEMOUND RD APPLETON WI 54914 -0 730 -0205 Lot Area S.. ft. 1/4, 1 /4,Section ,T N,R E(or)W Building Address Subdivision Name Lot No. Block No. 2852 MONTCLAIR PL 2nd add't. to Fox Chase 45 Zoning District(s) Zoning Permit No. Front Right .. . lallillii 1 0 New ❑ Repair 0 Single Family Entrance Panel Q Forced Air Fumace Fuel Nat. Oil Elec. Solid Sola ❑ Alteration Two Family Size: 200 am. Radiant Baseboard or Panel Ga -® ❑ j El Garage ❑ Addition g Service: ❑ Heat Pump Space Htg 1121 ❑ ❑ ❑ ❑ ❑ ❑ Move ❑ Other (print): ❑ Overhead ❑ Boiler Water Htg 0 ❑ ❑ ❑ ❑ ❑ Q Underground El Other: 0 Central Air Conditioning * • Dwelling unit will have 3 kilowatt or _. �'' °' " "' I. Other more installed electric space heating equip. Co ncr ete Q Site Construc Infiltration control option is: ❑ Full sealing Unfinished ❑ Manufactured ❑ Masonry ❑ Treated Wood Sewer of joints. El Blower door test. ❑ Exterior Basement 1113 Sq. ft R „ 0 Municipal air infiltration barrier. 1 - Sto ❑ Other Living Area 2274 Sq. ft. -Story ❑ Septic Q 2 -Story = Perm No. Envelope 31644 BTU /HR Garage 588 Sq. ft. ❑Other ❑ Seasonal Infiltration 20508 BTU /HR 0 Permanent 4 Municipal Utility ❑ Plus Basement ❑ Other ❑ Private On -Site Well $145,000.00 The applicant agrees to comply with all applicable codes, statues and ordinances and with the conditions of this permit, understands that the issuance of the permit creates no legal liability, express or • plied, on . - Departme , t or municipality; and certifies that all the above information is a • rate. APPLICANTS SIGNATURE ii, / DATE SIGNED S/ 3 ' 02_ This p= it s is- ed pursua .the following conditions. Failure to comply may result in suspe' ion or APPROVAL CONDITIONS revocation . thi • permit o di penalty See "Standard Conditions of Approval" sheet ❑ Town ❑ Village 0 City ❑ County • State of: Municipality Number of Dwelling Location: City Of Oshkosh 7 0 - 2 6 6 Plan Review $75.00 121 Construction Inspection ■ HVAC Name John Zarate I. Electrical Wis. Permit Seal $30.00 Plumbing Date 5/30/02 Other n Erosion Total $105.00 ❑ 270701 Cert. No. 70330 SBD -5823 (R. 07/92) OSHKOSH C:D PARKLAND DEDICATION FEE COLLECTION RECORD ON THE WATER Job Address 2852 MONTCLAIR PL Date 05/31/2002 Name HEARTLAND HOMES CONST. Address 1750 WOODSTOCK ST Oshkosh WI 54901 Subdivision 2nd add't. to Fox Chase Lot 45 Building Permit Number 0094777 Number of Dwelling Units 1 Number of Structures 1 Fee Required $100.00 Fee Paid Owner's Signature Date f37 // L Ott Inspector's Signature Date CITY OF OSHKOSH STANDARD CONDITIONS OF APPROVAL Project Address ZBSZ HoAZJai 1L Permit # Please read the following information and sign at the bottom to acknowledge that you have read and agree to comply with these conditions. 1. All habitable rooms must be provided with 8% light and 3.5% ventilation. Bedrooms located on the second floor or below ground level must be provided with egress windows in addition to the light and ventilation requirements. Basement windows are also required to have window well areas in accordance with ILHR 21.03. 2. Garage spaces shall be separated from the dwelling unit in accordance with ILHR 21.08. The door and frame assembly between the dwelling unit and an attached garage shall be labeled by an independent testing agency as having a minimum fire - resistive rating of 20 minutes. All drywall joints are required to be taped/sealed unless the joints are fitted so that the gap is no more than a dimes thickness ( 1/20 -inch) and backed by solid wood or drywall with the joints staggered. 3. All penetrations in exterior walls must be sealed prior to the insulation inspection. This includes holes in the top and bottom plates, gaps around heating ducts, and holes in the return air spaces. 4. Smoke detectors are required on every floor and within 6' of all bedrooms. The smoke detectors are required to be hardwired and interconnected. 5. Hydromassage tubs are required to have an access panel to motor. The access panel must be accessible without removing the finish of the house. 6. All overframing must be designed by the truss manufacturer, according to standards set by the truss plate institute, or structural calculations must be provided prior to the rough building inspection. 7. Truss plans must be submitted and approved prior to framing the roof. 8. Truss plans including the truss layout must be provided on site at the rough building inspection. In addition to the truss plans, microlam calculations must be provided on site at the rough building inspection for all microlams with point loads on them. 9. Calculations must be provided for all cantilevered floors with point loads. Floor trusses and TJI's must be designed for the cantilevered areas. 10. The property owner and applicant is responsible for compliance with ILHR 21.125 (Erosion Control). When installing access drives, a minimum of 2 " -3" diameter stone is required in addition to a minimum of 6" depth, 30' -50' length, and 14' -20' width. Erosion control measures must be maintained until the lawn is established. 11. All storm sewer inlets must be protected with approved erosion control devices. Tracking (i.e. sediment) must be removed from the street at the end of each workday. Repair any siltation or erosion damage to adjoining surfaces and drainageways resulting from land development or disturbing activities. 12. The building placard must be posted on site at all times. Once the rough framing is up the placard must be posted on the patio door or on a kitchen window. If the placard is not present at any inspection, stop work orders will be posted. Additional placards can be obtained through our department if the cards are misplaced. 13. All mechanicals must be roughed in prior to requesting the rough building inspection. If on the inspection the mechanicals are not roughed in, the inspection will fail and a $100 re- inspection fee will be charged. 14. Attached is a copy of the final inspection checklist. At the final inspection all items on this list must be completed to avoid the $100 re- inspection fee per inspection. 15. When requesting final inspections please note that a minimum of 2 days notice is needed from the time the inspection is ready. Furniture is only allowed to be placed in the center of the garage floor and a minimum of a 3' pathway must be provided around the walls of the garage. At the final inspection no furniture or personal belongings are allowed in the house. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in place due to the electrical inspector needing to look at the power serving the appliances. A 6' stepladder must be on site at the final inspection to provide access to the attic. 16. The building placard must remain on the patio door or on a kitchen window until occupancy is approved. Occupancy is not allowed prior to the placard having all of the final inspection approved stickers on the backside. If occupancy occurs prior to the inspections being approved daily citations will be issued with no further notice being given. 17. All site grading must be done in accordance with the approved drainage plan on file in the public works office, 3rd floor. S ilnalure o /.. ppticanl: /� m ale: 3/ v INPr 58'-2" i iir CL -9-4-11.1 ` ) / If 1 / 7v.l7 i 7971., b N 0 slIFK PILE i - \ C4 r ` l 1 PATIO 9 • - 13.8 12.2' ....' p l r ■ ci) ° HOUSE l o l PLAN# LI 2- 2274 -302 N m il l s. z �-- 7 LE I s' c 7 • 6 m — 25' -0" 20' GARAGE In N ,'--\--' l 24' _._. L tD_-5 UNES r O= DRIVEWAY 24' MAX. A N RIGHT OF WAY UNE * ILT FENC 7f7 93 �7 8z SILT FENCE MONTCti4 PLACE • R IS THE CONTRACTOR'S IRIEPONSOJIY 1b ENSURE PROPER = OR OMR AMMO BY USE OF M i aNOS SY WCAL AUTHORITY. NIN A .. 131061011 CONTROL EPIC OR COMM CONSULT LUCK 21.126. LUIR 21.13. AND LOCAL. OUILCMO OF THE STOCKPILE INIIPEC OR FOR ANY WORM Persil A 2 . itiodektitz hect- Ames, •Veesirn, bate 3-0- 1 o 1EOr'r.m ( Heartland Homes, TEL 0) 416-111111 FAX MO) 418-N