Loading...
HomeMy WebLinkAbout17063-Plumbing (03/25/2011) 0 INSPECTION SERVICES DIVISION ROOM 205 CITY OF OSHKOSH DEPARTMENT OF COMMUNITY DEVELOPMENT 215 CHURCH AVE OSHKOSH CORRECTION NOTICE PO Box 1130 ON THE WATER OSHKOSH WI 54903 -1130 Issue Date 3/25/2011 Compliance Date 4/24/2011 Compliance No Address 1727 ELMWOOD AVE Name Address City State Zip Code Sent to Lij Owner AARON E DROESSLER/RONALD C WIE 3139 BROOKS RD OSHKOSH WI 54904 -8532 Required for Occupancy Occupancy Introduction A final inspection of the plumbing on 3/24/2011 revealed the following violations: Item # 1 Code Comm. 82.30(9) Compliance No Compliance Date 04/24/2011 IMMEDIATELY Description Proper drainage pattern fittings are required from vertical to horizontal at the kitchen sink drain in basement near the sill plate 03/25/2011 and at the 3" stack in the basement receiving the 2nd floor waste discharge. Last Updated Item # 2 Code Comm. 82.40(4) Compliance No Compliance Date 04/24/2011 IMMEDIATELY Description A control valve shall be installed in the supply piping to each exterior hose bibb. 03/25/2011 Last Updated Item # 3 Code Comm. 82.40(7) Compliance No Compliance Date 04/24/2011 IMMEDIATELY Description The sizing of the water supply system shall be based on the empirical method and limitations outlined in this subsection or on 03/25/2011 a detailed engineering analysis acceptable to the department. A water calculation worksheet is required to be submitted to insure proper pipe sizing. Last Updated Item # 4 Code Comm. 82.40(8) Compliance No Compliance Date 04/24/2011 IMMEDIATELY Description All plumbing fixtures, appliances and appurtenances with 3/8" or larger inlet openings and with solenoid actuated quick closing 03/25/2011 valves shall be provided with water hammer arrestors. The dishwasher and automatic clothes washer fixture supplies required hammer arrestors. Last Updated Item # 5 Code Comm. 82.41(3) Compliance No Compliance Date 04/24/2011 IMMEDIATELY Description Water supply systems and the connection of each plumbing fixture, piece of equipment, appliance 03/25/2011 or nonpotable water piping system shall be designed, installed and maintained in such a manner to prevent the contamination of water supplies by means of cross connections. The hose bibb installed in the basement at the water meter requires proper Last cross connection protection. Updated 17063 Page 1 of 3 INSPECTION SERVICES DIVISION ROOM 205 CITY OF OSHKOSH DEPARTMENT OF COMMUNITY DEVELOPMENT 215 CHURCH AVE OSHKOSH CORRECTION NOTICE PO Box 1130 ON THE WATER OSHKOSH WI 54903 -1130 Issue Date 3/25/2011 Compliance Date 4/24/2011 Compliance No Address 1727 ELMWOOD AVE Name Address City State Zip Code Sent to U Owner AARON E DROESSLER/RONALD C WIE 3139 BROOKS RD OSHKOSH WI 54904 -8532 Hi Required for Occupancy Occupancy Introduction A final inspection of the plumbing on 3/24/2011 revealed the following violations: Item # 6 Code Comm. 82.41 Table 2 Compliance No Compliance Date 04/24/2011 IMMEDIATELY Description Self- draining outside silcock complying with ASSE 1019A is required to be installed to drain dry. Silcock is currently 03/25/2011 backpitched preventing the outlet to drain down. Last Updated 17063 Page 2 of 3 (1D INSPECTION SERVICES DIVISION ROOM 205 CITY OF OSHKOSH DEPARTMENT OF COMMUNITY DEVELOPMENT 215 CHURCH AVE OSHKOSH CORRECTION NOTICE PO Box 1130 ON THE WATER OSHKOSH WI 54903 -1130 Issue Date 3/25/2011 Compliance Date 4/24/2011 Compliance No Address 1727 ELMWOOD AVE Name Address City State Zip Code Sent to Owner AARON E DROESSLER/RONALD C WIE 3139 BROOKS RD OSHKOSH WI 54904 -8532 Li Required for Occupancy Occupancy Introduction A final inspection of the plumbing on 3/24/2011 revealed the following violations: Item # 7 Code Comm. 21 Compliance No Compliance Date 04/24/2011 IMMEDIATELY Description Draft stopping is required to be provided in the basement at the ceiling /floor connections below the bathtub and at the 3" pvc 03/25/2011 pipe penetrations below the 1st floor bathroom and laundry area. Last Updated Summary You shall be required to comply and call for re- inspection prior to occupancy. Violations must be corrected and approved within 30 days unless otherwise noted. Call for reinspections prior to concealment and /or occupancy. Upon completing the corrections, the owner /contractor /agent must sign and date at the bottom of this notice and return it to the Inspection Services Division by the Compliance Date of 4/24/2011 Office hours for obtaining permits are Monday through Friday 7:30 -8:30 a.m. and 12:30 -1:30 p.m. or by appointment. To schedule inspections please call th Inspection Request line at 236 -5128 noting the address, permit number (when applicable), and the nature of what needs a inspected. Signature Date ' 2 . ) / / I Inspected by: Paul Wolf 236 -5052 pwolf @ci.oshkosh.wi.us I hereby certify the violations listed on this report have been corrected in compliance with the applicable codes. Print Name Company Signature Date Also Sent to: u Bldg - u Elec - u HVAC - u Plbg BARTELT PLUMBING 2659 YORKTON PL Oshkosh WI 54904 -0 Li Designer _ J Other - y Inspector John Zarate 17063 Page 3 of 3