HomeMy WebLinkAbout2011-Bldg, HVAC & Lighting #R3-3243-0311 City of Oshkosh Division of Inspection Services 215 Church Avenue PO Box 1130 Oshkosh WI 54903 -1130 www.ci.oshkosh.wi.us OJHKOIH ON THE WATER March 21, 2011 Mark Finneman Michael Webert Finn Daniels Architects Emanuelson Podas 2145 Ford Parkway, Suite 301 10401 Bren Road East Saint Paul, MN 55116 Minnetonka, MN 55343 Dave Spring Beth Breinig BFO Factory Shops LLC Christopher & Banks LLC 5000 Hakes Drive 2400 Xenium Lane N Muskegon, MI, 49441 Plymouth, MN 55441 Site: Plan Number: R3- 3243 -0311 Christopher & Banks 3001 S Washburn St. Space D240 Oshkosh WI 54904 For: Description: Tenant space alterations Object Type: Building and HVAC and Lighting Class of Construction: IIB - 3800 Sq Ft.; sprinklered Occupancy: M: Mercantile / Retail Maximum No of Occupants: 109 The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in Chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements Key Item(s) / Conditions: • IBC 906.1 / IFC 906.3 The maximum travel distance allowed to a fire extinguisher is 75 feet. • IBC 901.2 Fire protection systems shall be installed, repaired, operated and maintained in accordance With this code and the international fire code. Construction of new walls may require the addition and or relocation of sprinkler heads to maintain required coverage, and not obstruct spray patterns of fire sprinklers. • IBC 1011 Exit signs are required to be installed per this section • IBC 1006.1 Means of egress illumination is required to be installed per this section • IBC 1006.3 Means of egress illumination is required to be installed per this section. All paths of egress are required to have adequate emergency lighting to meet the performance requirements of IBC 1006.4. Existing means of egress emergency lighting is permitted to be maintained in compliance with the code in effect at the time of construction. Any altered path of egress, or new path of egress, and any new emergency lighting being installed is required to comply with current code requirements. 1 31;c1 ,..,, .; u.,, St Sr:- D-2-0 LI 1_ 2,1 .. , . Only you page 1 of 3 • ANSI A117.1 Fixed Side Wall Grab Bars. A vertical grab bar 18 inches minimum length shall be mounted with the bottom of the bar located between 39 inches and 41 inches above the floor and with the center line of the bar located between 39 inches and 41 inches from the rear wall. • IBC 2902..1 / Table 2902 Drinking water is required to be provided. No drinking fountain is shown on plans drinking water is required to be provided in conformance with this code. • IMC 606.4.1 The duct smoke detectors shall be connected to a fire alarm system. The actuation of a smoke detector shall activate a visible and audible supervisory signal at a constantly attended location. • IMC 606.4.1 Exception 2. In occupancies not required to be equipped with a fire alarm system, actuation of a smoke detector shall activate a visible and an audible signal in an approved location. Smoke detector trouble conditions shall activate a visible or audible signal in an approved location and shall be identifies as air duct detector trouble. • Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve rules under this code and which are made to construction documents that have previously been granted approval by the department or its authorized representative, shall be submitted to the office that granted the approval. All revisions and modifications to plans shall be approved in writing by the department or its authorized representative prior to the work involved in the revision or modification being carried out. A revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with Comm 61.31(1). • MUN 30 This review does not include review for signage. Applications for and questions regarding signage permits should be directed to Todd Muehrer — Zoning Administrator (920) 236 -5057. SUBMIT: • IBC 1006.3 Means of egress illumination is required to be installed per this section. All paths of egress through The Retail Display area are required to have adequate emergency lighting to meet the performance requirements of IBC 1006.4. Provide complete emergency lighting plan showing compliance with these requirements prior to installation of emergency lighting system. — Photometric plans were not included in plan submittal. A copy of the City of Oshkosh Policy on Emergency Lighting is attached to this letter. • IMC 403.3.4 Balancing. Ventilation systems shall be balanced by an approved method. Such balancing shall verify that the ventilation system is capable of supplying the airflow rates required by Section 403. Balancing report required to be submitted prior to final occupancy being allowed. • Comm 61.40 (4) Supervision. Prior to the initial occupancy of a new building or addition and prior to the final occupancy of an alteration of an existing building the supervising professional shall file a compliance statement form SBD -9720 with this office. Note: Submittal of a compliance statement will be considered as evidence that the supervising professional has properly addressed all items identified in this plan review letter. A copy of the approved plans, specifications, and this letter shall be on -site during construction. If plan index sheets were submitted in lieu of additional full plan sets, a copy of this approval letter and index sheet shall be attached to plans that correspond with the copy on file with the copy on file in this office. All permits are required to be obtained prior to commencement of work. page 2 of 3 it In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. The City of Oshkosh does not take responsibility for the design or construction of the reviewed items. Inquiries concerning this correspondence may be made to me at the number listed below or the address on this letterhead. Respect •ue• Brian Noe Building Systems Consultant (920) 236 -5051 bnoe@ci.oshkosh.wi.us cc: Property file Fee Required $ 600.00 Fee Received $ 600.00 Balance Due $ 0.00 page 3 of 3