Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
0145119-Electric
0 CITY OF OSHKOSH No 145119 OSHKOSH ELECTRIC PERMIT - APPLICATION AND RECORD ON THE WATER Job Address 990 CUMBERLAND TRL Owner HUGO M GONZALEZ Create Date 03/08/2011 Contractor HULLAR ELECTRIC LLC Category 633 - Residential - Multi- Family Addition /Re Plan Service Q New Change Q Temp • N/A Type Q Overhead ( Underground Volts Circuits Luminaires Amps Switches Receptacles Appliances Use /Nature of ,MF\ Repairs following water damage. Panels in utility closets have insufficient workwpace, TR recepts required, AFCIs required, any Work NM cable that got wet shall be replaced, luminaires in water damage area to be replaced. Damaged feeder cable at service point to be repaired as well. ``Firestop documnetation attached Fees: Valudtion $3,700.00 Plan Approval $0.00 Permit Fee Paid $111.00 Issued By: 4 Date 03/11/2011 ❑ Permit Voided Parcel Id # 1311890200 In the performance of this work I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure any necess pprovals starting such activity. Signature r fs %� Date 3 o Agent/Owner Address 4932 W 9TH STREET RD OSHKOSH WI 54904 - 6530 Telephone Number. (920) 233 -3667 To schedule inspections please call the Inspection Request line at 236 -5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. City of Oshkosh Division of Inspection Services P.O. Box 1130 0 Oshkosh, WI 54903 -1130 Phone (920) 236 -5050 Fax (920) 236 -5084 Of HK0JH ON THE WATER ELECTRICAL PERMIT APPLICATION All information after bold categories must be provided. Incomplete applications will not be processed. • Application(s) and fee(s) can be brought to City Hall, Room 205 or mailed to Inspection Services, PO Box 1128, Oshkosh WI 54903 -1128. Commencing work without permit(s) will result in fees being doubled or $100.00 plus the normal permit fee, which ever is greater. OR If you are a contractorparticipatinz in the Permit Fee Account System and have adequate funds, check here if you want this processed through your account ❑ /l DATE 3 )/ -// JOB ADDRESS C nt�fr/..e."( / OWNER t CONTRACTOR /-/ . / /_r ir -l CHECK Vi ALL APPLICABLE USE CATEGORY ❑Single Family ❑Duplex li4ulti Family ❑Rental ❑Commercial ❑Industrial SERVICE DNew ❑Temporary TYPE ❑Overhead ❑Not Applicable ❑Change ❑Not Applicable ❑Underground FILL IN THE APPROPRIATE BLANK WITH THE NUMBER Volts / Receptacles # Circuits # Phase Amps Switches # Fixtures # CHECK 171 ALL APPLICABLE ❑Range ❑Dishwasher ❑Garbage Disposal DDryer ❑Water Heater ❑Fan OR Blower ❑Furnace DA/C DElectric Sign ❑Motors ❑Gas Pumps ❑Other n DESCRIPTION OF ALL WORK BEt4...-A. ING DONE t4...-A. k t�...�„ L t (� 7 ,1, c r vzi �h✓� VALUE (Including labor and all material includ' g ligh xtures) $ 3 2,'0, U � MASTER ELECTRICIAN / /�-- 3/02 System No. C -AJ -3030 a - March 05, 2007 p F Ratings— 1-1/2, 2 and 3 Hr (See Item 5) C T Rating — 0 Hr L Rating At Ambient — 129 CFM /sq ft L Rating At 400 F — 92 CFM /sq ft 0 CD A _.... o 0 o 0 0 .,,, •.� '4.... ,, +. •. ? Y J �_, .tr , y d:•x 'h . / . },:::., , • s�. . � • .ii :m ; ,•� E i• i . / ... ?.i. ∎. G I t r •' 0.107..01■1.WHIa'..' .4 w 411) I I , , N .. , ,,,. © SE CTION A -A L -A 1. Floor or Wall Assembly - Min 2 -1/2 in. (64 mm) thick lightweight or normal weight (100 -150 pcf or 1600 -2400 kg /m') concrete. Wall may also be constructed of any UL Classified Concrete Blocks *. Max diam of opening is 8 in. (203 mm). (...0 See Concrete Block (CAZT) category in the Fire Resistance Directory for names of manufacturers. O 2. Sleeve (Optional) Nom 8 in. (203 mm) diam (or smaller) Schedule 40 (or heavier) steel pipe or nom 6 in. (152 mm) diam (or smaller) O Schedule 40 polyvinyl chloride (PVC) pipe cast into floor or wall assembly. Sleeve to be flush with or project max 2 in. (51 mm) from top PP Y P j ( P N surface of floor or both surfaces of wall. When PVC sleeve is used, max cable conductor size is No. 12 AWG. As an alternate, nom 8 in. (203 (p mm) diam (or smaller) sleeve fabricated from nom 0.019 in. (0.48 mm) thick galv steel cast or grouted into floor or wall assembly flush with CD - • floor or wall surfaces. <^ 3. Cables -- Aggregate cross - sectional area of cables to be min 10 percent to max 40 percent of the cross- sectional area of the opening. Cables to be rigidly supported on both sides of the floor or wall assembly. Any combination of the following types and sizes of cables may be used: A. Max 1000 kcmil single- conductor copper or aluminum power cable; cross - linked polyethylene insulation. B. Max No. 2/0 AWG multiconductor copper or aluminum power cables; cross - linked polyethylene, polyvinyl chloride, neoprene rubber, hypalon or silicone rubber insulation and jacket materials. C. Max No. 12 AWG multiconductor copper control cables; cross - linked polyethylene, polyvinyl chloride, neoprene rubber, hypalon or silicone rubber insulation and jacket materials. D. Max 400 pair No. 24 AWG copper telephone cables; polyvinyl chloride insulation and jacket materials. E. Multiple fiber optical communication cable jacketed with PVC and having a max outside diam of 5/8 in. O F. Max 200 pair No. 22 AWG (or smaller) copper conductor with polyvinyl chloride (PVC) insulation and jacketing material. g G. Max 3/C No. 3/0 AWG (or smaller) copper or aluminum conductor SER cables with PVC insulation and jacket. n H. Max 3/C No. 2/0 AWG (or smaller) copper conductor PVC jacketed aluminum clad or steel clad TECK 90 cable. N 1. Max 3/C with ground No. 8 AWG (or smaller) copper conductor NM cable with PVC insulation and jacket. J. RG /U coaxial cable with fluorinated ethylene (FE) or PVC insulation and jacket. K. Max 4 pair No. 24 AWG (or smaller) copper conductor data cable with Hylar jacket and insulation. L. Max 3/C No. 12 AWG (or smaller) MC (BX) copper cable with polyvinyl chloride insulation and jacket materials. M. Through Penetrating Product* — Any cables, Armored Cable+ or Metal Clad Cable+ currently Classified under the Through Penetrating Product category. See Through Penetrating Product (XHLY) category in the Fire Resistance Directory for names of manufacturers 4. acking Material Min 1 in. (25 mm) thickness of 4 pcf (64 kg /m') mineral wool batt insulation firmly packed into opening as a p ermanent form. Packing material to be recessed from top surface of floor or sleeve or from both surfaces of wall or ends of sleeve as n required to accommodate the required thickness of fill material (Item 5). a III This material was extracted and drawn by 3M Fire Protection Products from the 2007 edition of the UL Fire Resistance Directory. c Ous 340 w Fire Protection r Products C-A,1-3030. 1 of 2 Product Support � on 1-800-3284687 or FAX O D System No. C -AJ -3030 continued 5. F' Void or Cavity Material* – Caulk or Sealant – Applied to fill the through opening to a min thickness of 1 in. (25 mm) flush with the 0 op surface of the floor or sleeve or both surfaces of wall or ends of sleeve. Caulk to be forced into interstices of cable group to max extent :._ possible. F Rating of firestop systems is dependent upon the through opening size, the thickness of the concrete, the sleeve type and percent 2 cable fill, as tabulated below: C Max Through Min Concrete Sleeve % Cable F Rating Opening Diam In. (mm) Thkns In. (mm) Type Fill Hr s 6 (152) 2 -1/2 (64) PVC 15 -40 2 a) 6 (152) 2 -1/2 (64) PVC 10 -15 3 o 6(152) 4- 1/2(114) PVC 10 -40 3 s 6(152) 4- 1/2(114) None 10 -40 3 F- 6 (152) 4 -1/2 (114) Steel 10 -40 3 8 (203) 2 -1/2 (64) None 15 -40 1 -1/2 8 (203) 4 -1/2 (114) None 15 -33 2 8 (203) 2 -1/2 (64) None 10 -15 3 8 (203) 2 -1/2 (64) Steel 15 -40 1 -1/2 8 (203) 2 -1/2 (64) Steel 10 -15 3 8(203) _ 4 -1/2 (114) Steel 10 -22 3 3M COMPANY – CP 25WB+ caulk or FB -3000 WT sealant. *Bearing the UL Classification Marking v a) ' L a) v) O O 0 a) V C 0 U This material was extracted and drawn by 3M Fire Protection Products from the 2007 edition of the Ul Fire Resistance Directory. c 4l- us V 3M Fire Protection Products ProductSupportLine:1 -800- 328 -1687 www.3m.com /firestop C -A. 1 - 303 0. 2 of 2 Choose option 4 for FAX ON DEMAND 341