HomeMy WebLinkAbout2011-Plumbing #L1-413-0211-P Oshkosh Plan Approval Form
OSHKOSH
ON THE WATER
Job Address 1515 PLANEVIEW DR Approval Number 3232
Approval Type Plumbing Plan L1 -413- 0211 -P
Submitter's Name Martenson & Eisele, Inc Net Days to
Address 1377 MIDWAY RD Complete Review
MENASHA WI 54952 - 449 2
Owner Name COBBLESTONE INN
Address
OSHKOSH WI 54904 - 0
Type of Plan Exterior Plumbing Review for Cobblestone Inn
Fee $710.00 Date Received 02/28/2011 Date Approved 3/7/2011
City of Oshkosh
Inspection Services
215 Church Ave., PO Box 1130
Oshkosh, WI 54902 -1130
(920) 236 -5052 (920) 236 -5184 FAX
OJHKOJH
ON THE WATER
March 7, 2011
Martenson & Eisele, Inc.
1377 Midway Rd
Menasha, WI. 54952
Exterior Plumbing - Cobblestone Inn
Ref: Plumbing Plan Approval: 1515 Planeview Dr, Oshkosh, WI
Plan ID# L1- 413 - 0211 -P
Dear Sirs,
Examination of the plumbing plans and specifications for this project has been completed. In
accord with Chapter 145, Wisconsin Statute, and COMM 81 through 85, Wisconsin
Administrative Code, the plumbing plans and specifications are approved contingent upon
compliance with the stipulation(s) noted below.
1. The plumber responsible for the installation shall keep at the construction site at
least one set of plans bearing the department's or agent municipality's stamp of
approval and least one set of specifications. The plans and specifications shall be
open to inspection by an authorized representative of the department. Comm.
82.20(6)
2. Sanitary building sewers 6" or less in diameter shall be provided with cleanouts or
manholes in compliance with Comm. 82.35(3)(b). Based on conversation with the
Department, it has been determined that the sanitary manhole indicated on page
C2.0 of the Utility Layout Plan shall be located such that a maximum of 200' length
of 6" sewer piping is allowed downstream of the manhole to the municipal sanitary
main. Note: This may be accomplished by relocating the manhole a minimum 78'
downstream or by adding an additional cleanout downstream of the manhole.
3. A means to locate buried non - metallic sanitary sewers and private interceptor main
sewers discharging to municipal mains shall be accomplished by an approved
method per Comm. 82.30(11)(h). Per Comm. 82.36(7)(d)10. a means to locate
buried non - metallic storm building sewers and private interceptor main sewers that
discharge to municipal mains shall be provided in accordance with the options under
s. Comm. 82.30(11)(h), except as provided in subd. 10.b. Per Comm. 82.40(8)(k)1.
a means to locate buried non - metallic water services and private water mains
connected to municipal supply systems shall be provided in accordance with the
options under s. Comm. 82.30(11)(h), except as provided in subds. 2. and 3.
In the event installation of this plumbing system has not commenced within two years from this
date, this approval shall become void. A new application accompanied by full examination
fees shall be filed and an updated approval received before work may commence.
In granting this approval, the City of Oshkosh or its representative does not hold itself liable for
any defects in plans or specifications, plan omissions, examination oversight, construction or
any damage that may result in or after installation. The City of Oshkosh reserves the right to
order changes or additions should conditions arise making this necessary.
It shall be necessary for the installing plumber to obtain a plumbing permit from the City of
Oshkosh before proceeding with actual installation of this plumbing system or any of its parts.
Respectfully,
Paul Wolf,
Plumbing Inspector