HomeMy WebLinkAbout0071587-Plumbing (interior) CITY OF OSHKOSH No 0071587
OSHKOSH PLUMBING PERMIT - APPLICATION AND RECORD
ON THE WATER
Job Address 3181 MOCKINGBIRD WAY Owner STEVE LICHTWALD Create Date 06/14/99
Contractor WATTERS PLBG- OSHKOSH Category 410 - Residential- Interior Plan
Bathtub 1 Shower 1 Ejector /Grind _ Dip Well F Prep Sink Gar Drain
Whirlpool Floor Drain 1 Water Softner Drink Ftn Sery Sink Soda Disp
Lavatory 2 Lndry Tray Local Waste Wait. St. Shamp Sink Coffee Maker
Toilet 2 Lndry Stndp 1 Clothes Wshr Ice Chest Flr/Wst Sink Int Grease Trap
Res. Sink 1 Disposal 1 Bidet Exam Sink Catch Basin Ext Grease Trap
Bar Sink Dishwasher 1 Beer Tap Sculry Sink Wash Ftn
Water Heater 1 Sump Pump 1 Dent. Oper. Hand Sink Urinal
Site Drain Classrm Sink _ Lab Sink Plaster Sink Standp Rec
Roof Drain Breakrm Sink Sterilizer Surgeons Sink Ice Maker
Use /Nature
of Work
NSFR
Size Material Type # Conn. Type
Sanitary Sewer
Storm Sewer
Water Service
Valuation $4,845.00 Plan Approval $0.00 Permit Fees $52.00
Issued By Date 07/21/99
❑ Permit Voided 1
In the performance of this work, I agree to perform all work pursuant to rules governing the described construction.
Signature Date
Agent/Owner
Address STATE RD 44 Oshkosh WI 54901 - 0 Telephone Number 235 -7060
Plumbing Permit Work Card
Job Address 3181 MOCKINGBIRD WAY Permit Number / 1I 5 6I Create Date 06/14/99
Owner STEVE LICHTWALD Contractor WATTERS PLBG- OSHKOSH
Category 410 - Residential- Interior Plan Value $0.00
htub 1/ Shower Ejector /Grind Dip Well F Prep Sink Gar Drain
Whirlpool Floor Drain / Water Softner Drink Ftn Sery Sink Soda Disp
Lavatory / / Lndry Tray Local Waste Wait. St. Shamp Sink Coffee Maker
Toilet / / Lndry Stndp / Clothes Wshr Ice Chest Flr/Wst Sink Int Grease Trap
Res. Sink / Disposal / Bidet Exam Sink Catch Basin Ext Grease Trap
Bar Sink Dishwasher / Beer Tap Sculry Sink Wash Ftn
Water Heater / Sump Pump / Dent. Oper. Hand Sink Urinal
Site Drain Classrm Sink Lab Sink Plaster Sink Standp Rec
Roof Drain Breakrm Sink Sterilizer Surgeons Sink Ice Maker
Use /Nature
of Work
NSFR 4 (—Aft 5
Size Material Type # Conn.Type
Sanitary Sewer
f ( ij/ /4)// 9 99
Storm Sewer
water Service
Date Type Inspector J Approved
OCT -28 -1999 17 08 WATTERS PLUMBING L '/ 920 733 2713 P.02/02
WATER CALCULATION WORKSHEET FOR 4 g^ 01 1 M a r t 1Tc�^� c. ?i 1 / /oc k - b -J
NAME OF PROJECT
INFORMATION REQUIRED TO CALCULATE WATER SERVICE SIZE
1. Demand of building in building in gallons per minute. WSFU's le
_= (GPM) ./a •P
2. Difference in elevation from main or external pressure tank to building control valve. (feet) / a
3_ Size of water meter (when meter is required) 5/8" 3/4° Y, 1" _, 1 -1/2" �._ 2" _ , larger size
4. Developed length from main or external pressure tank to building control valve. (feet) S O
5. Low pressure at main in street or external pressure tank. (psi) SO
CALCULATE WATER SERVICE PRESSURE LOSS
6. Low pressure at main in street or external pressure tank. (value of # 5 above) S-0
7. Determine pressure loss due to friction in / inch diameter SPs' S
Water service. Subtract value of 47"
(Water service piping material is ? �u s )
subtotal 51/6r-
8. Determine pressure loss due to elevation, <1- ? Cf
(multiply the value of* 2 above by .434) Subtract value of "8"
9_ Available pressure after the bldg. control valve. (enter in."8" below) subtotal 1 /O, L 6
CALCULATE THE PRESSURE AVAILABLE FOR UNIFORM LOSS (VALUE OF "A ")
B. Available pressure after the bldg. control valve. (from "9" above) Value of "B° y ' 6
C. Pressure loss of water meter (when meter is required) Subtract value of "C" _ PAC
subtotal -W- /4
D. Pressure at controlling fixture. Subtract value of "D" 0
(Controlling fixture is SL.►.,-- ) /8 f4.
subtotal
E. Difference in elevation between the building control valve 4,' .
and the controlling fixture in feet / 0 _ X .434 psi/ft. Subtract value of "E" .
subtotal / 3 ga
F. Pressure Toss due to water treatment devices, instantaneous
water heaters and backflow preventers which serve the
controlling fixture. Subtract value of "F
(Pressure loss due to t.
subtotal / 3.5
G. Developed length from building control valve to controlling -7 SS
fixture in feet .S X1.5 Divide by value of °G"
subtotal _ • /
(Water distribution piping material is t / P 1 )
�! Multiply by 100
A. Pressure available for uniform loss "A" = /p" `/
TOTAL P.02