Loading...
HomeMy WebLinkAboutCertificate of Occupancy CITY HALL 215 Church Avenue P 0 Box 1130 Oshkosh Wisconsin 54902 -1 City of Oshkosh 0/-1K0/1-1 ON THE WATER Approved: May 5, 2000 Issued: May 15, 2000 Roger / Angela Stephan 3181 Mockingbird Way Oshkosh, WI 54904 CERTIFICATE OF OCCUPANCY An Occupancy Permit is hereby issued for the new single family residence with attached garage and deck located at 3181 Mockingbird Way," Oshkosh, Wisconsin 54904 as described in Building Permit Application number (s) 70749. This building is to be used only as a new single family dwelling only and is located in the R -1 Single Family Residence District. LIMITATIONS: Maximum Floor Loading: 40 lbs. per square foot live load Maximum persons and /or living units: One living unit NOTES: A new Certificate of Occupancy shall be required prior to occupancy, should additional building(s) be erected, or should any buildings mentioned above be altered or moved. The use of land, or buildings, shall not be changed until a Certificate of Occupancy is issued for that occupancy. All conditions noted above must be complied with in order for this certificate to be valid. BUILDING INSPECTOR Cc: Landmark Building Building Permit Work Card Job Address 3181 MOCKINGBIRD WAY Permit Number 0070749 Create Date 06/11/1999 Owner STEVE LICHTWALD Contractor LANDMARK BLDG Category 110 - New Single Family Type 0 Building 0 Sign 0 Canopy 0 Fence 0 Raze Plan C7- 081 -699R Zoning R -1 Class of Const: 8 Size IRR 50'X42' Value $118,000.00 Unfinished /Basement 1052 Sq. Finished /Living 1184 Sq. Ft. Garage 484 Sq. Ft. Ft. Rooms 8 Bedrooms 4 Baths 2 El Projection Stories Bi -level Height 22 Ft. Canopies Signs Foundation Poured Concrete 0 Floating Slab 0 Pier 0 Other Concrete Block 0 Post 0 Treated Wood Occupany Permit Required Flood Plain No Height Permit Not Require( Park Dedication Required # Dwelling Units 1 # Structures 1 Use /Nature NSFR/ Bi -level w/ 2 car attached garage, 10'x10' deck. of Work HVAC Contr MCM HEATING Plumbing Contr WATTERS PLBG- OSHKOSH Electric Contr CUMINGS ELECTRIC Inspections: Date 12/21/1999 Type Final Inspector NRK _J Approved RE- INPSECTION 1) Graspable handrail is req. off the rear deck 2) Exterior brick is not installed Date 04/07/2000 Type Final Inspector NRK J Approved RE- INSPECTION 1) Exterior handrails shall be constructed of metal, decay resistant, or pressure treated wood 2) Handrails shall be symmetrical about the vertical centerline to allow for equal wrap around of the thumb and fingers. $25 re- inspection fe Date 05/05/2000 Type Final Inspector NRK U Approved Building Permit Work Card Job Address 3181 MOCKINGBIRD WAY Permit Number 0070749 Create Date 06/11/1999 Owner STEVE LICHTWALD Contractor LANDMARK BLDG Category 110 - New Single Family Type • Building 0 Sign 0 Canopy 0 Fence 0 Raze I Plan C7- 081 -699R Zoning R -1 Class of Const: 8 Size IRR 50'X42' Value $118,000.00 Unfinished /Basement 1052 Sq. Finished /Living 1184 Sq. Ft. Garage 484 Sq. Ft. Ft. Rooms 8 Bedrooms 4 Baths 2 C] Projection I Stories Bi -level Height 22 Ft. Canopies Signs Foundation Poured Concrete 0 Floating Slab 0 Pier 0 Other Concrete Block 0 Post 0 Treated Wood Occupany Permit Required Flood Plain No Height Permit Not Requires Park Dedication Required # Dwelling Units 1 # Structures 1 Use /Nature NSFR/ Bi -level w/ 2 car attached garage, 10'x10' deck. of Work HVAC Contr MCM HEATING Plumbing Contr WATTERS PLBG- OSHKOSH Electric Contr CUMINGS ELECTRIC Inspections: Date 11/04/1999 Type Final Inspector NRK u Approved Cont- 13) The step from the house to the garage is 12.5" high, max. 8" 14) Combustion air must be provided for the confined utility room NOTE: OWNERS HAVE MOVED IN, OCCUPANCY IS NOT APPROVED Date 11/11/1999 Type Final Inspector NRK Li Approved RE- INSPECTION Scheduled for 10:15a.m. NO ACCESS, OWNERS WERE NOT HOME Date 11/18/1999 Type Final Inspector NRK LI Approved RE- INSPECTION 1) Graspable handrail is req off the rear deck 2) Secure step from the house to the garage 3) Exterior brick is not installed, inspection req. 4) Provide hard pipe for gas dryer exhaust Date 11/18/1999 Type Final Inspector NRK U Approved Cont- 5) Fumace condensate drain is located in the doorway 6) Vapor barrier is not secured $25 re- inpsection fee Building Permit Work Card Job Address 3181 MOCKINGBIRD WAY Permit Number 0070749 Create Date 06/11/1999 Owner STEVE LICHTWALD Contractor LANDMARK BLDG Category 110 - New Single Family Type • Building 0 Sign 0 Canopy 0 Fence 0 Raze Plan C7- 081 -699R Zoning R -1 Class of Const: 8 Size IRR 50'X42' Value $118,000.00 Unfinished /Basement 1052 Sq. Finished /Living 1184 Sq. Ft. Garage 484 Sq. Ft. Ft. Rooms 8 Bedrooms 4 Baths 2 0 Projection Stories Bi -level Height 22 Ft. Canopies Signs Foundation Poured Concrete 0 Floating Slab 0 Pier 0 Other Concrete Block 0 Post 0 Treated Wood Occupany Permit Required Flood Plain No Height Permit Not Requires Park Dedication Required # Dwelling Units 1 # Structures 1 Use /Nature NSFR/ Bi -level w/ 2 car attached garage, 10'(10' deck. of Work HVAC Contr MCM HEATING Plumbing Contr WATTERS PLBG- OSHKOSH Electric Contr CUMINGS ELECTRIC Inspections: Date 09/15/1999 Type Insulation Inspector NRK Li Approved Date 11/04/1999 Type Final Inspector NRK U Approved 1) Post city house #'s 2) Exterior siding is not installed 3) Seal all holes through the fire - seperation wall 4) Provide a 20 min. listed and labeled door between the house and garage Date 11/04/1999 Type Final Inspector NRK HI Approved Cont- 5) Provide a code compliant exit off the patio door 6) Heat grills are not in place 7) Metal pipe req for gas dryer, plastic venting is not allowed 8) Firestop area in utility room that connects with the bathroom shower Date 11/04/1999 Type Final Inspector NRK J Approved Cont- 9) Seal holes through the return air spaces 10) Vapor barrier must be installed properly, edges must be taped or sealed to top and bottom plates 11) Gas fireplace is not hooked up 12) The furnace condensate is located in the doorway Building Permit Work Card Job Address 3181 MOCKINGBIRD WAY Permit Number 0070749 Create Date 06/11/1999 Owner STEVE LICHTWALD Contractor LANDMARK BLDG Category 110 - New Single Family Type • Building 0 Sign 0 Canopy 0 Fence 0 Raze Plan C7- 081 -699R Zoning R -1 Class of Contt: 8 Size IRR 50'X42' Value $118,000.00 Unfinished /Basement 1052 Sq. Finished /Living 1184 Sq. Ft. Garage 484 Sq. Ft. Ft. Rooms 8 Bedrooms 4 Baths 2 0 Projection Stories Bi -level Height 22 Ft. Canopies Signs Foundation Poured Concrete 0 Floating Slab 0 Pier 0 Other Concrete Block 0 Post 0 Treated Wood Occupany Permit Required Flood Plain No Height Permit Not Requires Park Dedication Required # Dwelling Units 1 # Structures 1 Use /Nature NSFR/ Bi -level w/ 2 car attached garage, 10'x10' deck. of Work HVAC Contr MCM HEATING Plumbing Contr WATTERS PLBG- OSHKOSH Electric Contr CUMINGS ELECTRIC Inspections: Date 08/18/1999 Type Rough In Inspector Nicole Krahn u Approved Cont- 9) Currently there is no header carrying the floor trusses under the stairway 10) Insullation must be properly placed behind the service panel 11) Firestop all dead spaces at the ceiling levels 12) Fireplace is not installed Date 08/18/1999 Type Rough In Inspector Nicole Krahn U Approved Cont- 13) Hurricane clips are not installed properly Date 08/27/1999 Type Rough In Inspector Nicole Krahn L J Approved RE- INSPECTION Items 1,6,8,10 are not done off the original list * *DO NOT INSULATE THE AREA WHERE THE AIR BREAK IS REQ FOR THE FLOOR TRUSSES Provide a 20 min. listed frame and door Date 09/15/1999 Type Rough In Inspector Nicole Krahn Li Approved RE- INSPECTION Fixed per the calcs submitted 20 min door is not listed Building Permit Work Card Job Address 3181 MOCKINGBIRD WAY Permit Number 0070749 Create Date 06/11/1999 Owner STEVE LICHTWALD Contractor LANDMARK BLDG Category 110 - New Single Family Type • Building 0 Sign 0 Canopy 0 Fence 0 Raze I Plan C7- 081 -699R Zoning R -1 Class of Const: 8 Size IRR 50'X42' Value $118,000.00 Unfinished /Basement 1052 Sq. Finished /Living 1184 Sq. Ft. Garage 484 Sq. Ft. Ft. Rooms 8 Bedrooms 4 Baths 2 f Projection Stories Bi -level Height 22 Ft. Canopies Signs Foundation O Poured Concrete 0 Floating Slab 0 Pier 0 Other Concrete Block 0 Post 0 Treated Wood Occupany Permit Required Flood Plain No Height Permit Not Requires Park Dedication Required # Dwelling Units 1 # Structures 1 Use /Nature NSFR/ Bi -level w/ 2 car attached garage, 10'x10' deck. of Work HVAC Contr MCM HEATING Plumbing Contr WATTERS PLBG- OSHKOSH Electric Contr CUMINGS ELECTRIC Inspections: Date Type Footings Inspector u Approved NO TIME Date 06/21/1999 Type Foundation Backfill Inspector Nicole Krahn u Approved Date 08/18/1999 Type Rough In Inspector Nicole Krahn Li Approved 1) Air barrier is req. on back side of gable end that is exposed to the attic 2) Firestop req. at the ceiling level for gable end 3) Min. 1" clearance must be provided around b -vent 4) Seal elec penetrations through return air spaces Date 08/18/1999 Type Rough In Inspector Nicole Krahn L-i Approved Cont- 5) Seal holes in elec boxes 6) Point loads from front widow and patio door do not line up on the trusses, sitting on the floor sheathing 7) Microlam calcs are req. for the lower level 8) Dampers for heat runs must be accessible Electric Permit Work Card Job Address 3181 MOCKINGBIRD WAY Permit Number 0071213 Create Date 06/14/1999 Owner STEVE LICHTWALD Contractor CUMINGS ELECTRIC Category 611 - Residential -New Single Family Wirin Service 01 New f Change U Temp Type '• Overhead D Volts 120/240 Switches J Neon Sign Neon # Amps 200 Fixtures Neon Transformers # Circuits Receptacles Value $3,000.00 Appliances Use /Nature Winng for NSFR of Work Inspections: Date 06/30/1999 Type Service Inspector KEVIN BENNER ✓ Approved 11:58 AM CALLED WPS 7/2/99, MAILED 7/6/99 Date 08/18/1999 Type Rough In Inspector KEVIN BENNER ✓J Approved 1:215 PM • Date 10/27/1999 Type Final Inspector KEVIN BENNER Approved 3:14 PM ( request from the G.C., the E.C. said it will be done after 10/28/99) NOT APPROVED / SEE FIELD CORRECTIONS the building inspector said the G.C. said they are not moving in until after 11/5/99. Date 12/21/1999 Type Final Inspector KEVIN BENNER INSPECTION REQUEST FROM THE BUILDING INSPECTOR FOR THIS PM HVAC Permit Work Card Job Address 3181 MOCKINGBIRD WAY Permit Number 0071316 Create Date 06/14/1999 Owner STEVE LICHTWALD Contractor MCM HEATING Category 502 - Residential -Both Plan - - Fuel Gas I 1 00 Electric Solar Solid Value $6,500.00 System 0 New n Replace n Other u Forced Air u Radiant _I Steam 4 NC u Vent u Electric u Hot Water u Suppl. u Con. Burner Chimney Type n Chimney A • Chimney B O Direct Vent O Not Applicable Heat Loss J As Approved 0 Existing 0 Not Applicable Value BTU Rate 0 As Per Plan 0 Variable 0 Other Value Use /Nature INSTALL CARRIER 58MXA060 FURNACE, 60,000 BTU of Work INSTALL CARRIER 38SKCO24 2 TON A/C, 10 SEER INSTALL RENEW -AIRE PVS -11 Inspections: Date 11/18/2000 Type Final Inspector Nicole Krahn u Approved re- inspect Date 12/21/1999 Type Final Inspector Nicole Krahn ✓j Approved Re- inspect HVAC Permit Work Card Job Address 3181 MOCKINGBIRD WAY Permit Number 0071316 Create Date 06/14/1999 Owner STEVE LICHTWALD Contractor MCM HEATING Category 502 - Residential -Both Plan Fuel 11 Gas I Oil 1 1 Electric I Solar 1 Solid Value $6,500.00 System 0 New ❑ Replace I El Other U Forced Air I Li Radiant Li Steam u NC Li Vent LJ Electric IJ Hot Water Li Suppl. L] Con. Bumer Chimney Type Q Chimney A • Chimney B Q Direct Vent 0 Not Applicable Heat Loss Q As Approved 0 Existing 0 Not Applicable Value BTU Rate Q As Per Plan Q Variable Q Other Value Use /Nature INSTALL CARRIER 58MXA060 FURNACE, 60,000 BTU of Work INSTALL CARRIER 38SKCO24 2 TON NC, 10 SEER INSTALL RENEW -AIRE PVS -11 Inspections: Date 08/18/1999 Type Rough In Inspector Nicole Krahn Li Approved Rough In HVAC - Fail see building list Date 08/27/1999 Type Rough In Inspector Nicole Krahn Li Approved Re- inspect Date 09/15/1999 Type Rough In Inspector Nicole Krahn U Approved Re- inspect Date 11/04/1999 Type Final Inspector Nicole Krahn Li Approved Plumbing Permit Work Card Job Address 3181 MOCKINGBIRD WAY Permit Number 0071587 Create Date 06/14/1999 Owner STEVE LICHTWALD Contractor WATTERS PLBG- OSHKOSH Category 410 - Residential Interior Plan Value $4,845.00 Bathtub 1 Shower 1 Ejector /Grind Dip Well F Prep Sink Gar Drain Whirlpool Floor Drain 1 Water Softner Drink Ftn Sery Sink Soda Disp Lavatory 2 Lndry Tray Local Waste Wait. St. Shamp Sink Coffee Maker Toilet 2 Lndry Stndp 1 Clothes Wshr Ice Chest Flr/Wst Sink Int Grease Trap Res. Sink 1 Disposal 1 Bidet Exam Sink Catch Basin Ext Grease Trap Bar Sink Dishwasher 1 Beer Tap Sculry Sink Wash Ftn Water Heater 1 Sump Pump 1 Dent. Oper. Hand Sink Urinal Site Drain Classrm Sink Lab Sink Plaster Sink Standp Rec Roof Drain Breakrm Sink Sterilizer Surgeons Sink Ice Maker Use /Nature of Work NSFR Size Material Type # Conn.Type Sanitary Sewer Storm Sewer Water Service Date 10/28/1999 Type Final Inspector WJC ✓1 Approved SEE CORR NOTICE