HomeMy WebLinkAboutCertificate of Occupancy CITY HALL
215 Church Avenue
P 0 Box 1130
Oshkosh Wisconsin
54902 -1 City of Oshkosh
0/-1K0/1-1
ON THE WATER Approved: May 5, 2000
Issued: May 15, 2000
Roger / Angela Stephan
3181 Mockingbird Way
Oshkosh, WI 54904
CERTIFICATE OF OCCUPANCY
An Occupancy Permit is hereby issued for the new single family residence
with attached garage and deck located at 3181 Mockingbird Way," Oshkosh,
Wisconsin 54904 as described in Building Permit
Application number (s) 70749.
This building is to be used only as a new single family dwelling only
and is located in the R -1 Single Family Residence District.
LIMITATIONS:
Maximum Floor Loading: 40 lbs. per square foot live load
Maximum persons and /or living units: One living unit
NOTES:
A new Certificate of Occupancy shall be required prior to occupancy,
should additional building(s) be erected, or should any buildings
mentioned above be altered or moved. The use of land, or buildings,
shall not be changed until a Certificate of Occupancy is issued for
that occupancy. All conditions noted above must be complied with in
order for this certificate to be valid.
BUILDING INSPECTOR
Cc: Landmark Building
Building Permit Work Card
Job Address 3181 MOCKINGBIRD WAY Permit Number 0070749 Create Date 06/11/1999
Owner STEVE LICHTWALD Contractor LANDMARK BLDG
Category 110 - New Single Family
Type 0 Building 0 Sign 0 Canopy 0 Fence 0 Raze Plan C7- 081 -699R
Zoning R -1 Class of Const: 8 Size IRR 50'X42' Value $118,000.00
Unfinished /Basement 1052 Sq. Finished /Living 1184 Sq. Ft. Garage 484 Sq. Ft.
Ft.
Rooms 8 Bedrooms 4 Baths 2 El Projection
Stories Bi -level Height 22 Ft. Canopies Signs
Foundation Poured Concrete 0 Floating Slab 0 Pier 0 Other
Concrete Block 0 Post 0 Treated Wood
Occupany Permit Required Flood Plain No Height Permit Not Require(
Park Dedication Required # Dwelling Units 1 # Structures 1
Use /Nature NSFR/ Bi -level w/ 2 car attached garage, 10'x10' deck.
of Work
HVAC Contr MCM HEATING Plumbing Contr WATTERS PLBG- OSHKOSH
Electric Contr CUMINGS ELECTRIC
Inspections:
Date 12/21/1999 Type Final Inspector NRK _J Approved
RE- INPSECTION
1) Graspable handrail is req. off the rear deck
2) Exterior brick is not installed
Date 04/07/2000 Type Final Inspector NRK J Approved
RE- INSPECTION
1) Exterior handrails shall be constructed of metal, decay resistant, or pressure treated wood
2) Handrails shall be symmetrical about the vertical centerline to allow for equal wrap around of the
thumb and fingers.
$25 re- inspection fe
Date 05/05/2000 Type Final Inspector NRK U Approved
Building Permit Work Card
Job Address 3181 MOCKINGBIRD WAY Permit Number 0070749 Create Date 06/11/1999
Owner STEVE LICHTWALD Contractor LANDMARK BLDG
Category 110 - New Single Family
Type • Building 0 Sign 0 Canopy 0 Fence 0 Raze I Plan C7- 081 -699R
Zoning R -1 Class of Const: 8 Size IRR 50'X42' Value $118,000.00
Unfinished /Basement 1052 Sq. Finished /Living 1184 Sq. Ft. Garage 484 Sq. Ft.
Ft.
Rooms 8 Bedrooms 4 Baths 2 C] Projection I
Stories Bi -level Height 22 Ft. Canopies Signs
Foundation Poured Concrete 0 Floating Slab 0 Pier 0 Other
Concrete Block 0 Post 0 Treated Wood
Occupany Permit Required Flood Plain No Height Permit Not Requires
Park Dedication Required # Dwelling Units 1 # Structures 1
Use /Nature NSFR/ Bi -level w/ 2 car attached garage, 10'x10' deck.
of Work
HVAC Contr MCM HEATING Plumbing Contr WATTERS PLBG- OSHKOSH
Electric Contr CUMINGS ELECTRIC
Inspections:
Date 11/04/1999 Type Final Inspector NRK u Approved
Cont-
13) The step from the house to the garage is 12.5" high, max. 8"
14) Combustion air must be provided for the confined utility room
NOTE: OWNERS HAVE MOVED IN, OCCUPANCY IS NOT APPROVED
Date 11/11/1999 Type Final Inspector NRK Li Approved
RE- INSPECTION
Scheduled for 10:15a.m. NO ACCESS, OWNERS WERE NOT HOME
Date 11/18/1999 Type Final Inspector NRK LI Approved
RE- INSPECTION
1) Graspable handrail is req off the rear deck
2) Secure step from the house to the garage
3) Exterior brick is not installed, inspection req.
4) Provide hard pipe for gas dryer exhaust
Date 11/18/1999 Type Final Inspector NRK U Approved
Cont-
5) Fumace condensate drain is located in the doorway
6) Vapor barrier is not secured
$25 re- inpsection fee
Building Permit Work Card
Job Address 3181 MOCKINGBIRD WAY Permit Number 0070749 Create Date 06/11/1999
Owner STEVE LICHTWALD Contractor LANDMARK BLDG
Category 110 - New Single Family
Type • Building 0 Sign 0 Canopy 0 Fence 0 Raze Plan C7- 081 -699R
Zoning R -1 Class of Const: 8 Size IRR 50'X42' Value $118,000.00
Unfinished /Basement 1052 Sq. Finished /Living 1184 Sq. Ft. Garage 484 Sq. Ft.
Ft.
Rooms 8 Bedrooms 4 Baths 2 0 Projection
Stories Bi -level Height 22 Ft. Canopies Signs
Foundation Poured Concrete 0 Floating Slab 0 Pier 0 Other
Concrete Block 0 Post 0 Treated Wood
Occupany Permit Required Flood Plain No Height Permit Not Requires
Park Dedication Required # Dwelling Units 1 # Structures 1
Use /Nature NSFR/ Bi -level w/ 2 car attached garage, 10'(10' deck.
of Work
HVAC Contr MCM HEATING Plumbing Contr WATTERS PLBG- OSHKOSH
Electric Contr CUMINGS ELECTRIC
Inspections:
Date 09/15/1999 Type Insulation Inspector NRK Li Approved
Date 11/04/1999 Type Final Inspector NRK U Approved
1) Post city house #'s
2) Exterior siding is not installed
3) Seal all holes through the fire - seperation wall
4) Provide a 20 min. listed and labeled door between the house and garage
Date 11/04/1999 Type Final Inspector NRK HI Approved
Cont-
5) Provide a code compliant exit off the patio door
6) Heat grills are not in place
7) Metal pipe req for gas dryer, plastic venting is not allowed
8) Firestop area in utility room that connects with the bathroom shower
Date 11/04/1999 Type Final Inspector NRK J Approved
Cont-
9) Seal holes through the return air spaces
10) Vapor barrier must be installed properly, edges must be taped or sealed to top and bottom plates
11) Gas fireplace is not hooked up
12) The furnace condensate is located in the doorway
Building Permit Work Card
Job Address 3181 MOCKINGBIRD WAY Permit Number 0070749 Create Date 06/11/1999
Owner STEVE LICHTWALD Contractor LANDMARK BLDG
Category 110 - New Single Family
Type • Building 0 Sign 0 Canopy 0 Fence 0 Raze Plan C7- 081 -699R
Zoning R -1 Class of Contt: 8 Size IRR 50'X42' Value $118,000.00
Unfinished /Basement 1052 Sq. Finished /Living 1184 Sq. Ft. Garage 484 Sq. Ft.
Ft.
Rooms 8 Bedrooms 4 Baths 2 0 Projection
Stories Bi -level Height 22 Ft. Canopies Signs
Foundation Poured Concrete 0 Floating Slab 0 Pier 0 Other
Concrete Block 0 Post 0 Treated Wood
Occupany Permit Required Flood Plain No Height Permit Not Requires
Park Dedication Required # Dwelling Units 1 # Structures 1
Use /Nature NSFR/ Bi -level w/ 2 car attached garage, 10'x10' deck.
of Work
HVAC Contr MCM HEATING Plumbing Contr WATTERS PLBG- OSHKOSH
Electric Contr CUMINGS ELECTRIC
Inspections:
Date 08/18/1999 Type Rough In Inspector Nicole Krahn u Approved
Cont-
9) Currently there is no header carrying the floor trusses under the stairway
10) Insullation must be properly placed behind the service panel
11) Firestop all dead spaces at the ceiling levels
12) Fireplace is not installed
Date 08/18/1999 Type Rough In Inspector Nicole Krahn U Approved
Cont-
13) Hurricane clips are not installed properly
Date 08/27/1999 Type Rough In Inspector Nicole Krahn L J Approved
RE- INSPECTION
Items 1,6,8,10 are not done off the original list
* *DO NOT INSULATE THE AREA WHERE THE AIR BREAK IS REQ FOR THE FLOOR TRUSSES
Provide a 20 min. listed frame and door
Date 09/15/1999 Type Rough In Inspector Nicole Krahn Li Approved
RE- INSPECTION
Fixed per the calcs submitted
20 min door is not listed
Building Permit Work Card
Job Address 3181 MOCKINGBIRD WAY Permit Number 0070749 Create Date 06/11/1999
Owner STEVE LICHTWALD Contractor LANDMARK BLDG
Category 110 - New Single Family
Type • Building 0 Sign 0 Canopy 0 Fence 0 Raze I Plan C7- 081 -699R
Zoning R -1 Class of Const: 8 Size IRR 50'X42' Value $118,000.00
Unfinished /Basement 1052 Sq. Finished /Living 1184 Sq. Ft. Garage 484 Sq. Ft.
Ft.
Rooms 8 Bedrooms 4 Baths 2 f Projection
Stories Bi -level Height 22 Ft. Canopies Signs
Foundation O Poured Concrete 0 Floating Slab 0 Pier 0 Other
Concrete Block 0 Post 0 Treated Wood
Occupany Permit Required Flood Plain No Height Permit Not Requires
Park Dedication Required # Dwelling Units 1 # Structures 1
Use /Nature NSFR/ Bi -level w/ 2 car attached garage, 10'x10' deck.
of Work
HVAC Contr MCM HEATING Plumbing Contr WATTERS PLBG- OSHKOSH
Electric Contr CUMINGS ELECTRIC
Inspections:
Date Type Footings Inspector u Approved
NO TIME
Date 06/21/1999 Type Foundation Backfill Inspector Nicole Krahn u Approved
Date 08/18/1999 Type Rough In Inspector Nicole Krahn Li Approved
1) Air barrier is req. on back side of gable end that is exposed to the attic
2) Firestop req. at the ceiling level for gable end
3) Min. 1" clearance must be provided around b -vent
4) Seal elec penetrations through return air spaces
Date 08/18/1999 Type Rough In Inspector Nicole Krahn L-i Approved
Cont-
5) Seal holes in elec boxes
6) Point loads from front widow and patio door do not line up on the trusses, sitting on the floor sheathing
7) Microlam calcs are req. for the lower level
8) Dampers for heat runs must be accessible
Electric Permit Work Card
Job Address 3181 MOCKINGBIRD WAY Permit Number 0071213 Create Date 06/14/1999
Owner STEVE LICHTWALD Contractor CUMINGS ELECTRIC
Category 611 - Residential -New Single Family Wirin
Service 01 New f Change U Temp Type '• Overhead D
Volts 120/240 Switches J Neon Sign Neon #
Amps 200 Fixtures Neon Transformers #
Circuits Receptacles Value $3,000.00
Appliances
Use /Nature Winng for NSFR
of Work
Inspections:
Date 06/30/1999 Type Service Inspector KEVIN BENNER ✓ Approved
11:58 AM
CALLED WPS 7/2/99, MAILED 7/6/99
Date 08/18/1999 Type Rough In Inspector KEVIN BENNER ✓J Approved
1:215 PM
•
Date 10/27/1999 Type Final Inspector KEVIN BENNER Approved
3:14 PM ( request from the G.C., the E.C. said it will be done after 10/28/99)
NOT APPROVED / SEE FIELD CORRECTIONS
the building inspector said the G.C. said they are not moving in until after 11/5/99.
Date 12/21/1999 Type Final Inspector KEVIN BENNER
INSPECTION REQUEST FROM THE BUILDING INSPECTOR FOR THIS PM
HVAC Permit Work Card
Job Address 3181 MOCKINGBIRD WAY Permit Number 0071316 Create Date 06/14/1999
Owner STEVE LICHTWALD Contractor MCM HEATING
Category 502 - Residential -Both Plan - -
Fuel Gas I 1 00 Electric Solar Solid Value $6,500.00
System 0 New n Replace n Other
u Forced Air u Radiant _I Steam 4 NC u Vent
u Electric u Hot Water u Suppl. u Con. Burner
Chimney Type n Chimney A • Chimney B O Direct Vent O Not Applicable
Heat Loss J As Approved 0 Existing 0 Not Applicable Value
BTU Rate 0 As Per Plan 0 Variable 0 Other Value
Use /Nature INSTALL CARRIER 58MXA060 FURNACE, 60,000 BTU
of Work INSTALL CARRIER 38SKCO24 2 TON A/C, 10 SEER
INSTALL RENEW -AIRE PVS -11
Inspections:
Date 11/18/2000 Type Final Inspector Nicole Krahn u Approved
re- inspect
Date 12/21/1999 Type Final Inspector Nicole Krahn ✓j Approved
Re- inspect
HVAC Permit Work Card
Job Address 3181 MOCKINGBIRD WAY Permit Number 0071316 Create Date 06/14/1999
Owner STEVE LICHTWALD Contractor MCM HEATING
Category 502 - Residential -Both Plan
Fuel 11 Gas I Oil 1 1 Electric I Solar 1 Solid Value $6,500.00
System 0 New ❑ Replace I El Other
U Forced Air I Li Radiant Li Steam u NC Li Vent
LJ Electric IJ Hot Water Li Suppl. L] Con. Bumer
Chimney Type Q Chimney A • Chimney B Q Direct Vent 0 Not Applicable
Heat Loss Q As Approved 0 Existing 0 Not Applicable Value
BTU Rate Q As Per Plan Q Variable Q Other Value
Use /Nature INSTALL CARRIER 58MXA060 FURNACE, 60,000 BTU
of Work INSTALL CARRIER 38SKCO24 2 TON NC, 10 SEER
INSTALL RENEW -AIRE PVS -11
Inspections:
Date 08/18/1999 Type Rough In Inspector Nicole Krahn Li Approved
Rough In HVAC - Fail see building list
Date 08/27/1999 Type Rough In Inspector Nicole Krahn Li Approved
Re- inspect
Date 09/15/1999 Type Rough In Inspector Nicole Krahn U Approved
Re- inspect
Date 11/04/1999 Type Final Inspector Nicole Krahn Li Approved
Plumbing Permit Work Card
Job Address 3181 MOCKINGBIRD WAY Permit Number 0071587 Create Date 06/14/1999
Owner STEVE LICHTWALD Contractor WATTERS PLBG- OSHKOSH
Category 410 - Residential Interior Plan Value $4,845.00
Bathtub 1 Shower 1 Ejector /Grind Dip Well F Prep Sink Gar Drain
Whirlpool Floor Drain 1 Water Softner Drink Ftn Sery Sink Soda Disp
Lavatory 2 Lndry Tray Local Waste Wait. St. Shamp Sink Coffee Maker
Toilet 2 Lndry Stndp 1 Clothes Wshr Ice Chest Flr/Wst Sink Int Grease Trap
Res. Sink 1 Disposal 1 Bidet Exam Sink Catch Basin Ext Grease Trap
Bar Sink Dishwasher 1 Beer Tap Sculry Sink Wash Ftn
Water Heater 1 Sump Pump 1 Dent. Oper. Hand Sink Urinal
Site Drain Classrm Sink Lab Sink Plaster Sink Standp Rec
Roof Drain Breakrm Sink Sterilizer Surgeons Sink Ice Maker
Use /Nature
of Work
NSFR
Size Material Type # Conn.Type
Sanitary Sewer
Storm Sewer
Water Service
Date 10/28/1999 Type Final Inspector WJC ✓1 Approved
SEE CORR NOTICE