HomeMy WebLinkAboutCertificate of Occupancy CITY HALL
215 Church Avenue
P. 0. Box 1130
Oshkosh, Wisconsin
54902 -1130 City of Oshkosh
O.IHKQ/H
ON THE WATER
Approved: September 13, 1999
Issued: September 20, 1999
GARRY H DECKER & CO
1113 OREGON ST.
OSHKOSH, WI 54901
CERTIFICATE OF OCCUPANCY
An Occupancy Permit is hereby issued for the new Single Family
Residence with attached garage and deck located at 3171 Mockingbird
Way, Oshkosh, WI 54904 as described in Building Permit Application
number(s) 66268.
This building is to be used as a Single Family Residence only and is
located in the R -1 Single Family Residence District.
LIMITATIONS:
Maximum Floor Loading: 40 lbs. per square foot live load
Maximum persons and /or living units: One Living Unit
CONDITIONS: None.
A new Certificate of Occupancy shall be required prior to occupancy,
should additional building(s) be erected, or should any buildings
mentioned above be altered or moved. The use of land, or buildings,
shall not be changed until a Certificate of Occupancy is issued for
that occupancy. All conditions noted above must be complied with in
order for this certificate to be valid.
� -9.14 £
BUILDING INSPECTOR
Building Permit Work Card
Job Address 3171 MOCKINGBIRD WAY Permit Number 0066268 Create Date 8/25/98
Owner GARRY DECKER Contractor GARRY H DECKER & CO 5/11/99
Category 110 - New Single Family
Type ® Building 0 Sign 0 Canopy 0 Fence 0 Raze Plan C6- 095 -998R
Zoning R -1 Class of Const: 8 Size IRR 64'X52' Value $92,000.00
Unfinished /Basement 0 Sq. Ft. Finished /Living 2976 Sq. Ft. Garage 756 Sq. Ft.
Rooms 8 Bedrooms 3 Baths 2 1 Projection
Stories Bi -level Height 23 Ft. Canopies Signs
Foundation ® Poured Concrete 0 Floating Slab 0 Pier 0 Other
0 Concrete Block 0 Post 0 Treated Wood
Occupany Permit Required Flood Plain No Height Permit Not Require
Park Dedication Required # Dwelling Units 1 # Structures 1
Use /Nature NSFR/ Constructing a raised ranch w/ a 3 car attached garage and a 13'x12' attached deck.
of Work
HVAC Contr TENTH ST STATION INC Plumbing Contr WATTERS PLUMBING
Electric Contr CUMINGS ELECTRIC
Inspections:
Date 11/24/98 Type Final Inspector NRK U Approved
(5) Grading is not done, keep the grade a min of 6" from the siding
$25 Reinspection Fee is due
Date 11/25/98 Type Final Inspector NRK Li Approved
The 2 doors were secured and the heating violations were taken care of. The handrails will be done by
12/02/98.
Date 12/3/98 Type Final Inspector NRK Approved
Building Permit Work Card
Job Address 3171 MOCKINGBIRD WAY Permit Number 0066268 Create Date 8/25/98
Owner GARRY DECKER Contractor GARRY H DECKER & CO 5/11/99
Category 110 - New Single Family
Type 0 Building 0 Sign Q Canopy 0 Fence Q Raze Plan C6- 095 -998R
Zoning R -1 Class of Const: 8 Size IRR 64X52' Value $92,000.00
Unfinished/Basement 0 Sq. Ft. Finished/Living 2976 Sq. Ft. Garage 756 Sq. Ft.
Rooms 8 Bedrooms 3 Baths 2 1 1 Projection
Stories Bi -level Height 23 Ft. Canopies Signs
Foundation Poured Concrete Q Floating Slab 0 Pier Q Other
Concrete Block 0 Post 0 Treated Wood
Occupany Permit Required Flood Plain No Height Permit Not Require
Park Dedication Required # Dwelling Units 1 # Structures 1
Use/Nature NSFR/ Constructing a raised ranch w/ a 3 car attached garage and a 13'x12' attached deck.
of Work
HVAC Contr TENTH ST STATION INC Plumbing Contr WATTERS PLUMBING
Electric Contr CUMINGS ELECTRIC
Inspections:
Date 10/7/98 Type Rough In Inspector Nicole Krahn 11 Approved
(1) Collars are required for the b -vents
(2) T- bracing is required for truss T -3 above the front entrance
(3) Firestopping required between studs at the ceiling and floor level (All horizontal and vertical spaces must
be firestopped)
Date 10/7/98 Type Rough In Inspector Nicole Krahn 11 Approved
Cont-
(4) The point loads from the header over the stairway requires the Toads to be transferred all the way down to
the foundation through the floorframing
(5) Calcs are required for the 2(2x8) header w/ the cantilevered window framing (lower level)
Date 10/7/98 Type Rough In Inspector Nicole Krahn u Approved
Cont-
(6) The sill of the windows in the lower level can be no more than 46" above the finish floor if bedrooms are to
be allowed
(7) Transfer all point loads through the box sill to the foundation
(8) Caulk all electrical wires in hvac returns
Date 11/24/98 Type Final Inspector NRK U Approved
(1) Graspable handrail required for the rear deck
(2) Hvac grills are not in place
(3) Hvac supply under kitchen cabinet is required to be panned off or a boot provided
(4) Handrail required for the exterior stairwell
Electric Permit Work Card
Job Address 3171 MOCKINGBIRD WAY Permit Number 0066559 Create Date 09/01/1998
Owner GARRY DECKER Contractor CUMINGS ELECTRIC
Category 611 - Residential -New Single Family Wirin
Service • New 0 Change 0 Temp Type 0 Overhead • Underground
Volts 120/240 Switches J Neon Sign Neon #
Amps 200 Fixtures Neon Transformers #
Circuits Receptacles Value $2,500.00
Appliances
Use /Nature Wiring for NSFR
of Work
Inspections:
Date 12/12/1998 Type Final Inspector KEVIN BENNER J Approved
RE- INSPECT // SEE ABOVE PH. # // NO TIME (12/30/98) \\
Date 03/08/1999 Type Final Inspector KEVIN BENNER j Approved
RE- INSPECT REQUESTED FOR 3/9/99 11:00 AM - 12:00 PM // NOT APPROVED , THE PANEL COVER
TRIM INSTALLATION WAS NOT MODIFIED. THE PANEL COVER CAN NOT BE REMOVED (readily). I
COULD NOT REMOVE IT. HYDRO ACCESS APPROVED.
Date 09/13/1999 Type Final Inspector KEVIN BENNER ✓J Approved
7:10 AM
INSPECT REQUEST FOR TUES 9/14/99 9:30 AM
Electric Permit Work Card
Job Address 3171 MOCKINGBIRD WAY Permit Number 0066559 Create Date 09/01/1998
Owner GARRY DECKER Contractor CUMINGS ELECTRIC
Category 611 - Residential -New Single Family Wirin.
Service New O Change O Temp Type 0 Overhead • Underground
Volts 120/240 Switches u Neon Sign Neon #
Amps 200 Fixtures Neon Transformers #
Circuits Receptacles Value $2,500.00
Appliances
Use /Nature Wiring for NSFR
of Work
Inspections:
Date 09/04/1998 Type Service Inspector KEVIN BENNER u Approved
CALLED INTO WPS 9/4/98 PM, MAILED 9/4/98
Date 10/07/1998 Type Rough In Inspector KEVIN BENNER u Approved
INSULATED 10/8/98 AM \\ I TALKED TO DICK W. ABOUT THIS NOT HAPPENING AGAIN. I ALSO SENT
A NOTICE TO GARY DECKER.
Date 11/23/1998 Type Final Inspector KEVIN BENNER U Approved
INSPECTION REQUESTED FOR 11/24/98 / POSTED 11/23/98 \ \\ NOT APPROVED SEE FEILD
CORRECTIONS. \\ NICOLE DID A RE- INSPECTION AND WAS NOT CORRECTED \\
Date 12/09/1998 Type Final Inspector KEVIN BENNER u Approved
RE- INSPECTION REQUESTED / HOMEOWNER PH.# 303 -2223 JOHN DORN // 12/11/98 NO ONE HOME
\\
HVAC Permit Work Card
Job Address 3171 MOCKINGBIRD WAY Permit Number 0068219 Create Date 9/10/98
Owner WELS CHURCH EXTENSION FUND Contractor TENTH ST STATION INC
Category 502 - Residential -Both Plan
Fuel IX Gas I 1 Oil Ni Electric I Solar 1 Solid Value $3,400.00
System M New Replace I Other
Kx Forced Air J Radiant u Steam A/C u Vent
u Electric J Hot Water Li Suppl. IJ Con. Burner
Chimney Type 0 Chimney A 0 Chimney B 0 Direct Vent • Not Applicable
Heat Loss 0 As Approved 0 Existing • Not Applicable Value
BTU Rate 0 As Per Plan Variable Other Value
Use /Nature New SFR/ Furnace and A/C
of Work
Inspections:
Date 12/3/98 Type Final Inspector NRK Approved
Plumbing Permit Work Card
Job Address 3171 MOCKINGBIRD WAY Permit Number 0066255 Create Date 09/03/98
Owner GARRY DECKER Contractor WATTERS PLUMBING
Category 410 - Residential- Interior Plan Value $6,726.00
Bathtub 1 Shower 1 Ejector /Grind Dip Well F Prep Sink Gar Drain
Whirlpool Floor Drain 1 Water Softner Drink Ftn Sery Sink Soda Disp
Lavatory 2 Lndry Tray Local Waste Wait. St. Shamp Sink Coffee Maker
Toilet 2 Lndry Stndp 1 Clothes Wshr Ice Chest Flr/Wst Sink Int Grease Trap
Res. Sink 1 Disposal 1 Bidet Exam Sink Catch Basin Ext Grease Trap
Bar Sink Dishwasher 1 Beer Tap Sculry Sink Wash Ftn
Water Heater 1 Sump Pump 1 Dent. Oper. Hand Sink Urinal
Site Drain Classrm Sink Lab Sink Plaster Sink Standp Rec
Roof Drain Breakrm Sink Sterilizer Surgeons Sink Ice Maker
Use /Nature
of Work
NSFR
Size Material Type # Conn.Type
Sanitary Sewer
Storm Sewer
Water Service
Date 9/3/98 Type Underground Inspector WJC N Approved
Date 10/12/98 Type Rough In Inspector wjc 1Xj Approved
Date 11/24/98 Type Final Inspector WJC N Approved
Plumbing Permit Work Card
Job Address 3171 MOCKINGBIRD WAY Permit Number 0067761 Create Date 11/24/98
Owner WELS CHURCH EXTENSION FUND Contractor WATTERS PLUMBING
Category 410 - Residential - Interior Plan Value $1,000.00
Bathtub Shower 1 Ejector /Grind Dip Well F Prep Sink Gar Drain
Whirlpool Floor Drain Water Softner Drink Ftn Sery Sink Soda Disp
Lavatory 1 Lndry Tray Local Waste Wait. St. Shamp Sink Coffee Maker
Toilet 1 Lndry Stndp Clothes Wshr Ice Chest Fir/Wst Sink Int Grease Trap
Res. Sink Disposal Bidet Exam Sink Catch Basin Ext Grease Trap
Bar Sink Dishwasher Beer Tap Sculry Sink Wash Ftn
Water Heater Sump Pump Dent. Oper. Hand Sink Urinal
Site Drain Classrm Sink Lab Sink Plaster Sink Standp Rec
Roof Drain Breakrm Sink Sterilizer Surgeons Sink Ice Maker
Use/Nature
of Work
XTRA FXTS TO PERMIT 66255 (FINISHED LL)
Size Material Type # Conn.Type
Sanitary Sewer
Storm Sewer
Water Service
Date 11/24/98 Type Final Inspector WJC Approved