Loading...
HomeMy WebLinkAboutCertificate of Occupancy CITY HALL 215 Church Avenue P. 0. Box 1130 Oshkosh, Wisconsin 54902 -1130 City of Oshkosh O1HKOJH ON THE WATER Approved: December 17, 1998 Issued: December 17, 1998 TEMPO DEVELOPMENTS INC 600 S MAIN ST OSHKOSH WI 54901 CERTIFICATE OF OCCUPANCY An Occupancy Permit is hereby issued for the new Single Family Residence with attached garage and no deck located at 3131 Mockingbird Way, Oshkosh, WI 54904 as described in Building Permit Application number(s) 64445. This building is to be used as a Single Family Dwelling only and is located in the R -1 Single Family Residence District. LIMITATIONS: Maximum Floor Loading: 40 lbs. per square foot live load Maximum persons and /or living units: One Living Unit CONDITIONS: A new Certificate of Occupancy shall be required prior to occupancy, should additional building(s) be erected, or should any buildings mentioned above be altered or moved. The use of land, or buildings, shall not be changed until a Certificate of Occupancy is issued for that occupancy. All conditions noted above must be complied with in order for this certificate to be valid. /4te,oki BUILDING INSPECTOR Building Permit Work Card Job Address 3131 MOCKINGBIRD WAY Permit Number 0064445 Create Date 6/3/98 Owner TEMPO DEVELOPMENTS Contractor TEMPO DEVELOPMENTS INC 5/23/97 Category 110 - New Single Family Type 0 Building O Sign 0 Canopy O Fence O Raze Plan C6- 062 -698R Zoning R -1 Class of Const: 8 Size 61'8 "X40' Value $85,000.00 Unfinished /Basement 1604 Sq. Finished /Living 1604 Sq. Ft. Garage 646 Sq. Ft. Ft. Rooms 6 Bedrooms 3 Baths 2 Projection Stories 1 Height 19 Ft. Canopies Signs Foundation !li Poured Concrete 0 Floating Slab 0 Pier 0 Other J Concrete Block 0 Post 0 Treated Wood Occupany Permit Required Flood Plain No Height Permit Not Require Park Dedication Required # Dwelling Units 1 # Structures 1 Use /Nature NSI-R/ 1 Story home w/ 3 car attached garage, NO DECKS OR PATIOS. of Work 1 HVAC Contr MCM HEATING Plumbing Contr WAITERS PLUMBING Electric Contr CUMINGS ELECTRIC Inspections: Date 12/10/98 Type Final Inspector NRK Approved (1) I he heat supply in the kitchen requires a boot or must be panned (2) The concrete step from the house to the garage is off more than 1/2" (3) Seal all gaps in the firewall along the ceiling level and around plumbing penetrations Date 12/10/98 Type Final Inspector NRK Approved Cont- (4) Calcs are required for the notched TJI (upper cord) next to the beam pocket at the farthest end of the basement (5) Draftstopping req for all penetrations through the floor sheathing (spaces greater than 4" req. plywood or drywall) Date 12/10/98 Type Final Inspector NRK Approved Cont- (6) A smoke detector is req within 6' of the bedroom /media room (7) Final grade must positively slope away from the basement windows. (Grade must be a min. of 2" below the basement windows and 6" from the siding. Building Permit Work Card Job Address 3131 MOCKINGBIRD WAY Permit Number 0064445 Create Date 6/3/98 Owner TEMPO DEVELOPMENTS Contractor TEMPO DEVELOPMENTS INC 5/23/97 Category 110 - New Single Family Type • Building 0 Sign O Canopy O Fence O Raze I Plan C6- 062 -698R Zoning R -1 Class of Const: 8 Size 61'8 "X40' Value $85,000.00 Unfinished /Basement 1604 Sq. Finished /Living 1604 Sq. Ft. Garage 646 Sq. Ft. Ft. Rooms 6 Bedrooms 3 Baths 2 Projection Stories 1 Height 19 Ft. Canopies Signs Foundation Poured Concrete 0 Floating Slab 0 Pier o Other J Concrete Block O Post O Treated Wood Occupany Permit Required Flood Plain No Height Permit Not Require Park Dedication Required # Dwelling Units 1 # Structures 1 Use /Nature NSFR/ 1 Story home w/ 3 car attached garage, NO DECKS OR PATIOS. of Work HVAC Contr MCM HEATING Plumbing Contr WAITERS PLUMBING Electric Contr CUMINGS ELECTRIC Inspections: Date 6/23/98 Type Foundation Backfill Inspector NRK > Approved (FOOTINGS ARE O.K. - Date 8/3/98 Type Rough In Inspector Nicole Krahn Approved — Neg. 8/3 L 9:59- key rt of o.h. door ADDITIONAL BEARING IS REQ. FOR THE 2 PLY GIRDER TRUSS IN THE FRONT BEDROOM (MIN 1STUD) DRAFTSTOPPING REQ. AT THE CEILING LEVEL FOR THE FIREPLACE DRAFTSTOPPING REQ. FOR CONCEALED SPACE BY THE B -VENT Date 8/5/98 Type Rough In Inspector NRK Approved CON r- BLOCK ALL POINT LOADS TO THE FOUNDATION NOTE: NO ACCESS TO THE BASEMENT DUE TO THE FLOOR BEING POURED Date 8/10/98 Type Insulation Inspector Brian Noe Approved io a ions a were no e• on ; -. - • . ave •een core e.. El ectric erm or aia Job Address 3131 MOCKINGBIRD WAY Permit Number 0065401 Create Date 6/11/98 Owner TEMPO DEVELOPMENTS Contractor CUMINGS ELECTRIC Category 611 - Residential -New Single Family Wirin Service I40 New O Change O Temp Type 0 Overhead 0 Underground Volts 120/240 Switches HI Neon Sign Neon 0 Amps 200 Fixtures Neon Transformers # Circuits Receptacles Value $2,500.00 Appliances Use /Nature /1/ NEW SFR HOUSE WIRING CEI JOB #8764 \ \\ of Work Inspections: Date 7/1/98 Type Service Inspector KEVIN BENNER LI Approved Date 8/3/98 Type Rough In Inspector KEVIN BENNER N Approved Date 12/9/98 Type Final Inspector KEVIN BENNER M Approved INSPECTION CALLED IN BY JIM C. OF TEMPO. LOCK BOX COMBO "OFF" Plumbing Permit Work Card Job Address 3131 MOCKINGBIRD WAY Permit Number 0065464 Create Date 06/11/98 Owner TEMPO DEVELOPMENTS Contractor WATTERS PLUMBING Category 410 - Residential- Interior Plan Value $5,669.00 Bathtub 2 Shower 1 Ejector /Grind Dip Well F Prep Sink Gar Drain Whirlpool Floor Drain 1 Water Softner Drink Ftn Sery Sink Soda Disp Lavatory 3 Lndry Tray Local Waste Wait. St. Shamp Sink Coffee Maker Toilet 3 Lndry Stndp 1 Clothes Wshr Ice Chest Flr/Wst Sink Int Grease Trap Res. Sink 1 Disposal 1 Bidet Exam Sink Catch Basin Ext Grease Trap Bar Sink Dishwasher 1 Beer Tap Sculry Sink Wash Ftn Water Heater 1 Sump Pump 1 Dent. Oper. Hand Sink Urinal Site Drain Classrm Sink Lab Sink Plaster Sink Standp Rec Roof Drain Breakrm Sink Sterilizer Surgeons Sink Ice Maker Use /Nature of Work NSF Size Material Type # Conn.Type Sanitary Sewer Storm Sewer Water Service Date 8/3/98 Type Underground Inspector WJC Approved RE- INSPECT Date 12/9/98 Type Final Inspector WJC X Approved I Plumbing Permit Work Card Job Address 3131 MOCKINGBIRD WAY Permit Number 0065464 Create Date 06/11/98 Owner TEMPO DEVELOPMENTS Contractor WATTERS PLUMBING Category 410 - Residential- Interior Plan Value $5,669.00 Bathtub 2 Shower 1 Ejector /Grind Dip Well F Prep Sink Gar Drain Whirlpool Floor Drain 1 Water Softner Drink Ftn Sery Sink Soda Disp Lavatory 3 Lndry Tray Local Waste Wait. St. Shamp Sink Coffee Maker Toilet 3 Lndry Stndp 1 Clothes Wshr Ice Chest Flr/Wst Sink Int Grease Trap Res. Sink 1 Disposal 1 Bidet Exam Sink Catch Basin Ext Grease Trap Bar Sink Dishwasher 1 Beer Tap Sculry Sink Wash Ftn Water Heater 1 Sump Pump 1 Dent. Oper. Hand Sink Urinal Site Drain Classrm Sink Lab Sink Plaster Sink Standp Rec Roof Drain Breakrm Sink Sterilizer Surgeons Sink Ice Maker Use /Nature of Work NSF Size Material Type # Conn.Type Sanitary Sewer Storm Sewer Water Service Date 7/31/98 Type Rough In Inspector WJC J Approved SEE CORR NOTICE Date 7/31/98 Type Underground Inspector WJC Approved — SEE CORR NOTICE I Date 8/3/98 Type Rough In Inspector WJC N Approved RE- INSPECT