HomeMy WebLinkAboutCertificate of Occupancy CITY HALL
215 Church Avenue
P 0 Box 1130
Oshkosh. Wisconsin
54902 -1130 City of Oshkosh
OJHKOJH
ON THE WATER
Approved: July 20, 2000
Issued: August 30, 2000
Bradley & Brenda Cirricione
3080 Mockingbird Way
Oshkosh, WI 54904
CERTIFICATE OF OCCUPANCY
An Occupancy Permit is hereby issued for the new single family homes with three car
attached garage, no deck or patio located at 3080 Mockingbird Way, Oshkosh, Wisconsin
54904 as described in Building Permit Application number(s) 73409.
This building is to be used as a Single Family Residence only and is located in
the R -1 Single Family Residence District.
LIMITATIONS:
Maximum Floor Loading: 40 lbs. per square foot live load
Maximum persons and /or living units: One Living Unit
CONDITIONS: 1) Final grading must be done in accordance with the approved
subdivision drainage plan. This plan is on file in the public works office, 3 rd
floor of City Hall.
2) Erosion control measures must be maintained until the lawn is established.
Note: Final grade must be a minimum of 6" below all siding.
3) Future permits may be required for additional work to your property.
A new Certificate of Occupancy shall be required prior to occupancy, should
additional building(s) be erected, or should any buildings mentioned above be
altered or moved. The use of land, or buildings, shall not be changed until a
Certificate of Occupancy is issued for that occupancy. All conditions noted above
must be complied with in order for this certificate to be valid.
Nicole Krahn
Building Systems Inspector
Cc: Dramatic Design
Building Permit Work Card
Job Address 3080 MOCKINGBIRD WAY Permit Number 0073409 Create Date 10/05/1999
Owner DRAMATIC DESIGN Contractor DRAMATIC DESIGN 7/99
Category 110 - New Single Family
Type • Building 0 Sign 0 Canopy 0 Fence 0 Raze Plan C7- 139 -999R
Zoning R -1 Class of Const: 8 Size IRR Value $100,000.00
Unfinished /Basement 1080 Sq. Finished/Living 2035 Sq. Ft. Garage 872 Sq. Ft.
Ft.
Rooms 7 Bedrooms 3 Baths 2 ❑ Projection
Stories 2 Height 27 Ft. Canopies Signs
Foundation Poured Concrete 0 Floating Slab 0 Pier 0 Other
Concrete Block 0 Post 0 Treated Wood
Occupany Permit Required Flood Plain No Height Permit Not Require(
Park Dedication Required # Dwelling Units 1 # Structures 1
Use /Nature NSFR/ 2 story w/ 3 car attached garage, NO DECK OR PATIO
of Work
HVAC Contr MCM HEATING Plumbing Contr WATTERS PLBG- OSHKOSH
Electric Contr SCHOMMER ELECTRICAL CON
Inspections:
Date 06/09/2000 Type Final Inspector NRK U Approved
Re- inspection
1) Install erosion control at the property line
2) Patio permit?
3) The door to the garage can not be listed in the field without UL approval -Frame must be replaced or
field listed
4) Safety glass required for windows within 2' of doors
Date 06/09/2000 Type Final Inspector Nicole Krahn U Approved
Cont. 5) Provide access to attic scuttle (a gasket will be required once the caulk is cut)
6) GFI receptalces in the basement are not working
7) Provide a plate for open receptacle kitchen breakfast area
Date 07/20/2000 Type Final Inspector Nicole Krahn
Re- inspection
Building Permit Work Card
Job Address 3080 MOCKINGBIRD WAY Permit Number 0073409 Create Date 10/05/1999
Owner DRAMATIC DESIGN Contractor DRAMATIC DESIGN 7/99
Category 110 - New Single Family
Type • Building 0 Sign 0 Canopy 0 Fence 0 Raze Plan C7- 139 -999R
Zoning R -1 Class of Const: 8 Size IRR Value $100,000.00
Unfinished /Basement 1080 Sq. Finished /Living 2035 Sq. Ft. Garage 872 Sq. Ft.
Ft.
Rooms 7 Bedrooms 3 Baths 2 ❑ Projection
Stories 2 Height 27 Ft. Canopies Signs
Foundation Poured Concrete 0 Floating Slab 0 Pier 0 Other
Concrete Block 0 Post 0 Treated Wood
Occupany Permit Required Flood Plain No Height Permit Not Require(
Park Dedication Required # Dwelling Units 1 # Structures 1
Use /Nature NSFR/ 2 story w/ 3 car attached garage, NO DECK OR PATIO
of Work
HVAC Contr MCM HEATING Plumbing Contr WATTERS PLBG- OSHKOSH
Electric Contr SCHOMMER ELECTRICAL CON
Inspections:
Date 02/15/2000 Type Rough In Inspector NRK 4 Approved
RE- INSPECTION
Date 02/15/2000 Type Insulation Inspector NRK 4 Approved
Date 06/06/2000 Type Final Inspector NRK U Approved
1) Install erosion control
2) Provide fire - seperation for garage areas canying the 2nd floor load
3) Patio permit required
4) Provide safety glazing for all windows within 2' of the patio door
Date 06/06/2000 Type Final Inspector NRK U Approved
Cont-
5) Provide access to the attic scuttle
6) Provide additional support for the basement handrail
7) Seal elec holes through retum air spaces (lined floor joist spaces)
8) Provide continuous handrail for the upper stairway
Building Permit Work Card
Job Address 3080 MOCKINGBIRD WAY Permit Number 0073409 Create Date 10/05/1999
Owner DRAMATIC DESIGN Contractor DRAMATIC DESIGN 7/99
Category 110 - New Single Family
Type • Building 0 Sign 0 Canopy 0 Fence 0 Raze Plan C7- 139 -999R
Zoning R -1 Class of Const: 8 Size IRR Value $100,000.00
Unfinished /Basement 1080 Sq. Finished /Living 2035 Sq. Ft. Garage 872 Sq. Ft.
Rooms 7 Bedrooms 3 Baths 2 ❑ Projection
Stories 2 Height 27 Ft. Canopies Signs
Foundation Poured Concrete 0 Floating Slab 0 Pier 0 Other
Concrete Block 0 Post 0 Treated Wood
Occupany Permit Required Flood Plain No Height Permit Not Requires
Park Dedication Required # Dwelling Units 1 # Structures 1
Use /Nature NSFR/ 2 story w/ 3 car attached garage, NO DECK OR PATIO
of Work
HVAC Contr MCM HEATING Plumbing Contr WATTERS PLBG- OSHKOSH
Electric Contr SCHOMMER ELECTRICAL CON
Inspections:
Date 10/18/1999 Type Footings Inspector Li Approved
NO TIME
Date 10/28/1999 Type Foundation Backfill Inspector NRK U Approved
1) Support req. for unsupported footing and foundation wall under porch area
2) Drain -tile systems are not tied together (quad level home)
Date 02/10/2000 Type Rough In Inspector NRK U Approved I
1) Seal elec wires through return air spaces
2) Insulation is not installed properly behind the tub /shower unit
3) Fire -stop ceiling of deadspace by shower unit, fireplace (vapor barrier req)
4) Transfer point Toad from 2 ply girder truss
Date 02/10/2000 Type Rough In Inspector NRK Li Approved
Cont-
5) Provide a min. of 6'4" headroom for all stairways
6) Provide microlam calcs and TJI layout and beam calcs
Electric Permit Work Card
Job Address 3080 MOCKINGBIRD WAY Permit Number 74346 Create Date 10/06/1999
Owner DRAMATIC DESIGN Contractor SCHOMMER ELECTRICAL CON
Category 611 - Residential -New Single Family Wirin
Service • New 0 Change Temp Type Overhead J
9 0 P YPe � Ovrhe
• Underground
Volts 120/240 Circuits Fixtures
Amps 200 Switches Receptacles
Fee $85.00 El Value $4,110.00
Appliances
Use /Nature NSFR
of Work
Inspections:
Date 11/03/1999 Type Service Inspector KEVIN BENNER u Approved
9:39 AM
NOT APPROVED / (no plastic on the electrical panel) / CALLED THE E.0 11/4/99
Date 11/04/1999 Type Service Inspector KEVIN BENNER �✓J Approved
7:56 AM
RE- INSPECT
FAXED TO WPS 11/4/99, MAILED 11/8/99
Date 06/08/2000 Type Final Inspector NRK _ J Approved
9:19 AM
OPEN BOX FOR THE AQUARIUM ( wire terminated on the breaker, breaker was taped off)
BASEMENT RECEPTACLES NOT FUNCTIONING
K.J.B. CALLED THE E.C. HE SAID HE WOULD CORRECT SAME DAY (6/9/00)
Date 07/20/2000 Type Fat Inspector Nicole Krahn Llej Approved
Re- inspection
HVAC Permit Work Card
Job Address 3080 MOCKINGBIRD WAY Permit Number 0073886 Create Date 10/06/1999
Owner DRAMATIC DESIGN Contractor MCM HEATING
Category 502 - Residential -Both Plan
Fuel ✓ Gas U Oil I Electric I Solar I Solid I Value $6,100.00
System Q New Replace j n Other
u Forced Air J Radiant J Steam IJ A/C u Vent
LJ Electric Li Hot Water J Suppl. U Con. Burner
Chimney Type ID Chimney A 0 Chimney B 0 Direct Vent 0 Not Applicable
Heat Loss IO As Approved 0 Existing 0 Not Applicable Value
BTU Rate 0 As Per Plan 0 Variable 0 Other I Value
Use /Nature NSFR/ install new furnace, A/C and ductwork
of Work
Inspections:
Date 07/20/2000 Type Final Inspector Nicole Krahn Approved
Re- inspection
HVAC Permit Work Card
Job Address 3080 MOCKINGBIRD WAY Permit Number 0073886 Create Date 10/06/1999
Owner DRAMATIC DESIGN Contractor MCM HEATING
Category 502 - Residential -Both Plan
Fuel Hi Gas Oil Electric Solar I Solid Value $6,100.00
System 7J New ❑ Replace n Other
Forced Air u Radiant u Steam u NC IJ Vent
Electric Li Hot Water HI Suppl. I IJ Con. Bumer
Chimney Type Q Chimney A Q Chimney B Q Direct Vent 0 Not Applicable
Heat Loss Q As Approved Q Existing 0 Not Applicable Value
BTU Rate Q As Per Plan Q Variable 0 Other I Value
Use /Nature NSFR/ install new fumace, NC and ductwork
of Work
Inspections:
Date 02/10/2000 Type Rough In Inspector Nicole Krahn J Approved
Fail see building notes
Date 02/15/2000 Type Rough In Inspector Nicole Krahn u Approved
Re- inspection
Date 06/06/2000 Type Final Inspector Nicole Krahn Hi Approved
Fail see building list
Date 06/09/2000 Type Final Inspector Nicole Krahn IJ Approved
Re- inspection fail see building notes
Plumbing Permit Work Card
Job Address 3080 MOCKINGBIRD WAY Permit Number 0075220 Create Date 10/06/1999
Owner DRAMATIC DESIGN Contractor WATTERS PLBG-OSHKOSH
Category 410 - Residential- Interior Plan - Value $6,493.00
Bathtub 2 Shower 1 Ejector /Grind Dip Well F Prep Sink Gar Drain
Whirlpool Floor Drain 1 Water Softner Drink Ftn Sery Sink Soda Disp
Lavatory 4 Lndry Tray Local Waste Wait. St. _ Shamp Sink Coffee Maker _
Toilet 4 Lndry Stndp 1 Clothes Wshr Ice Chest Flr/Wst Sink Int Grease Trap
Res. Sink 1 Disposal 1 Bidet Exam Sink Catch Basin Ext Grease Trap
Bar Sink Dishwasher 1 Beer Tap Sculry Sink Wash Ftn
Water Heater 1 Sump Pump 1 Dent. Oper. Hand Sink Urinal
Site Drain Classrm Sink Lab Sink Plaster Sink Standp Rec
Roof Drain Breakrm Sink Sterilizer Surgeons Sink Ice Maker
Use /Nature
of Work
NSFR
Size Material Type # Conn.Type
Sanitary Sewer
Storm Sewer
Water Service
Date 06/05/2000 Type Final Inspector WJC u Approved
SEE CORR NORICE