Loading...
HomeMy WebLinkAbout0077549-Building (deck) g ) CITY OF OSHKOSH No 0077549 OSHKOSH BUILDING PERMIT - APPLICATION AND RECORD ON THE WATER Job Address 3051 MOCKINGBIRD WAY Owner DANIEL NEY AND LORI KUHLOW Create Date 06/06/2000 Designer Contractor VALLEY FRAMING* Category 142 - Decks, Patios, Ramps Plan Type • Building 0 Sign 0 Canopy 0 Fence 0 Raze Zoning Class of Const: Size irr Unfinished /Basement Sq. Ft. Rooms Height Ft. ❑ Projection Finished /Living Sq. Ft. Bedrooms Stories Canopies Garage Sq. Ft. Baths Signs Foundation 0 Poured Concrete 0 Floating Slab 0 Pier 0 Other 0 Concrete Block • Post 0 Treated Wood Min. of 48" of frost protection Occupancy Permit Not Required Flood Plain Height Permit Park Dedication # Dwelling Units 0 # Structures 0 Use /Nature SFR/ Constructing a deck off the rear of the house. All construction must comply with min. state and local building code requirements. of Work (the deck under permit #70695 was never constructed) HVAC Contractor Plumbing Contractor Electric Contractor Fees: Valuation $4,000.00 Plan Approval $0.00 Permit Fee Paid $25.00 Park Dedication $0.00 Issued By: AK,.._ Date 06/06/2000 Final /O.P. ❑ Permit Voided In the performance of this work I agree to perform all work pursuant to rules governing the described construction. / G Signature , P j C Date 6/ 6 /7c) / ? cp 9 A ent/Own Address 3051 MOCKINGBIRD WAY Oshkosh _ 04 - 6311 Telephone Number KEVIEW AUT1I0R1IT ap ZONING/LAND USE COMPLIANCE CHECKLIST • JOB LOCATION: ) ZXa.vr \ ZONING - PROPER , CONSTRUCTION DATA: New Construction Addition _____ Alteration TYPE OF CONSTRUCTION: (i.e. fence, pool, parking lot, sign, etc.) •s1 2 C (J■k Q-' u t/ t?) COMPLIANCE CHECKLIST DEFICIENT COMMENTS Use Lot Width • • Lot Area ____ Lot Area Per Family Fioodpiain Front Yard Front Yard Side Street Rear Yard Side Yards Building Area Parking Standards Off- Street Loading Standards Vision Clearance _ Transitional Yard Standards Landscape Standards Height Conditions of Approval Compliance with P.C. or BZA Conditions of Approval Signage Standards Drainage Plan • REVIEW AUTHORITY As per Section 30-5 Enforcement of the City Zoning Ordinance, the Director of Community Development, or designee, must approval all plans, except the following: (1) Alterations or interior work when the use is conforming and when no change in use is proposed. (2) Maintenance items, e.g. siding, windows, etc., when the use is conforming and when no change is proposed. APPROVED _ DENIED Plan Commission Action Required Variance(s) Required REVIEWED BY: ) N,(// N,(// / 4/(1 DATE: i Ft[ /MRFR nn •..r.w . , Ns 97 10:58 FR MITEK INDUSTRIES INC 314 434 9110 TO NOFFKe•LUMBER P.02/02 r_,�t +aP Ines truss type Ohy 'P1y 4 VVALLEY T 1 M OD. QUEEN c - r 3 ) 3 l ( / / t 4 1 tg $U)-I -ICE LUM INC- USNI 0 WI. b4901 4 -0.32 s A 29' 997 Pala Industries, Inc. `Mon Nov 17 12:53:31 1981 Paps 1 i -0 5-5-10 11 -0-5 167.0 • 22-1-11 2748 33-40 35-24 0.2.0 5-5-10 5-6-11 5.6-11 54-11 54-11 5-7 -10 1-104 - 1 5a5-= /�,�v 4 4.,0 `' 11 7.0012 `� "' 3A5 i 3>. (` " k -Aj vlii1/4 ) ,,.. \ • 5Xa i 6 `21e4 7, ` 7 1 5x711 r1 1/ 8x6 �`/ / � a 4 P 12 11 10 ‘18 = 8dl= 3x5= SEE PETAN. BELOW . 8.30 16-74 24-11-0 - 0.2 84.0 8.40 8-40 860 LOADING tpsf) SPACING 2 -0-0 CSI DEFL (in) pod MA PLAIDS GRIP I TCLL 30.0 Notes Increase 1.15 TC 0.82 VettO .) - OA 3 11 > 999 M20 187/190 i TCDL 7.0 Lubber Increase 1.15 8C 0.58 Vert(TL) - 0.21 10-11 >999 I BOLL 0.0 Rep Stress In YES WB 0 - 30 Hort{TU 0.08 8 rile . 8C 3.0 Code 60CA/ANSI96 Mon Length / U. defl = 360 Weight: 150 m LUMBER BRACING TOP CHORO 2 X 4 SP1= Nc.2 TOP CHORD Sheathed or 3 - 3 - 13 on comer purlin spacslg• BOT CHORD 2 X 4 spy No,2 807 CHORD Rigid cuffing directly applied or 10-0 -0 on center bracing. WEBS 2 X 4 SPF No.2 "Except' WEBS 1 Row et rwdpt 3 5-11 _ 2 -12 2 X 4 SPF Stud, 7 -10 2 X 4 SPF Stud SLIDER Loft 2 X 4 SPF Stud 8.3.2 REACTIONS (lb/ate) 1=1327/0-5-8, 8 =1477/0.3 -8 FORCES (b) TOP CHORD 1 - = - 2023. 2.3 =- 1774, 3-4 =- 1270, 4-5= -1270. 5- 6= 4777, (1- 7.•1777, 7 -8s -2027, 84-28 l BOT CHORD 1 -12 -1896, 11-12.1431, 10-11 -1432, 8-10 -1700 WEBS 2 -12= -256, 9 -12= 267, 3-11=-528, 4-11=869. 5.11 =- 530, 5-10=271. 7 -10 =-260 1 NOTES 1) This trues has been checked for unbalanced loading oen&Rions. 2) The bottom chord dead bad shown it sufficient only to cover the truss weight itself and does not allow for any addltionaLload to be added to the bottom chard. 3) All plates are M20 plates unless otherwise indicated. 4) This truss has been designed with ANSI/TP) 1 -1996 Witaria. 1 LOAD CASE(S) Standard 1/4" 6 g P (M 1r SHIM PROVIDE RA.Lw000 1 S y 1:W000C0MTACIPRIOR a•.a•a 'a / In Pa IG w 0oM GCr olt L� e•• es PLATE ( la f "ESP. do.. * =MIN \Ill �; stLois) ;w 8 • AL V 0 � . _ 1 ,,,....., l2 DE awweulm a - Yait &Apt rerea eta. and 97-413 hoods ON IWO AND AOPI RNIC NM 111101111 MIL i t 0e ego VOW tar use Only wen Wet a0ette0to8. TM deign 8 bama only upon 11alam1ee !town, and Is tor m Ineth4aual outdl p component t0 be Metaled and sodded vaMCdry. Apploablity o1 design faisoossites and proper klo0rpasaflen of component Is to poum18y 01 bue0leg 0019014 - 1Ot Iva 4,09,.... twocen0 Maw. R Son 1oto.at wppoo of eldtileuel Web revalues all. A68110na tSnpotegY bta3141 l0 illule R09L 41Y1k10 C00861011c 118* elegro a uy of the creator. Ad:Plenaa permanent b.00M9 et the ovate slush., 8 8e atapsretaly of the oirigno designee. 10. Oorerd peewee ee Pending OuoltY Control SQOta9e, steamy, erection and bt0d110, cam* C l.8u deity chided. 05.88 WPM Ilgeolloollon. and 158.91 F 4ITae® Mrp ono Inane Rote ne Saoonweeson available barn Trove ob Insane., 585 Cot:Pero Om e. Mouton, W1 S371% ** TOTAL PAGE.002 ** 4 CANNQ-ek. Cedti Ja t\ 6t.. 3 (O r cov,c)A 'C_G. x t BeAtG . Cwt o ac /c4P-- W '► 1\ \04.... it ■ia l F t c ktvo rck oklrL 5. F� _Z o . 7 - A/ W. Building Permit Work Card Job Address 3051 MOCKINGBIRD WAY Permit Number 0077549 Create Date 06/06/2000 Owner DANIEL NEY AND LORI KUHLOW Contractor VALLEY FRAMING* Category 142 - Decks, Patios, Ramps Type • Building 0 Sign 0 Canopy 0 Fence 0 Raze I Plan Zoning Class of Const: Size irr Value $4,000.00 Unfinished/Basement Sq. Finished/Living Sq. Ft. Garage Sq. Ft. Ft. Rooms Bedrooms Baths El Projection Stories Height Ft. Canopies Signs Foundation Poured Concrete 0 Floating Slab 0 Pier 0 Other Concrete Block • Post 0 Treated Wood Min. of 48" of frost protection Occupany Permit Not Required Flood Plain Height Permit Park Dedication # Dwelling Units 0 # Structures 0 Use /Nature SFR/ Constructing a deck off the rear of the house. All construction must comply with min. state and local of Work building code requirements. (the deck under permit #70695 was never constructed) HVAC Contr Plumbing Contr Electric Contr Inspections: Date 06/12/2000 Type Footings Inspector Shaun Scullion 4 Approved POST HOLE INSPECTION- OK Date 07/05/2000 Type Final Inspector Shaun Scullion L✓j Approved Final inspection completed- OK