HomeMy WebLinkAbout1964-Building Y
OFFIC/AL NOTICE FROM
INSPECTORS OFFICE
CITY OF OSHKOSH
I r. Russell '','erch
NAME
A D D R E S S 241 Junction Street, Berlin, Wisconsin
4 ew iou :. e a 2J
EPA ENT EM I A R Ch N Ift,i ' O ii I`I OF T HE
er � 1�'eet, s o h,
DISCLOSES VIOLATIONS OF ThE FOLLOWIN SECTIONS' OF THE
GENERAL ORDINAt CE S Or THE CITY OF O , HKOSH
SECT/ON LOCATION E N EDEO COr.RECTIONS
15.02 (6) (b) (2) "13" Gas Vent - Keep 1" clearance from
combustible.
11.05 (1) (E) (c) Use Diagonal 1 x 4 inch braces set into studs
at external corners of building where composition
sheathing is used.
11.05 (m) (3) Jambs and heads of openings in non - bearing
Partitions shall be 2 x 4's doubled.
Call: 231 -4410 When the above is corrected.
THE ABOVE VIOL,AnuTIOsry N5 SHA�. BE CORRECTED ON OR BEFORE
ia
AT THE TIME1`':'Of� INSF uie TION THESE VIOLATIONS WERE POINTED
OUT T O r indq
1 -2J -b4
FATE OF INSPECTION