HomeMy WebLinkAboutBuilding & HVAC #90-10-0216-C ! State of Wisconsin \ Department of Industry, Labor and Human Relations SAFETY & BUILDINGS DIVISION November 12, 19911 201 E. Washington Avenue P.O. Box 7969 Madison, Wisconsin 53707 File slumber E -83762 Donald R. Holt Marcus Theatre Corporation Schroeder & Holt Architects 212 West Wisconsin Avenue 212 West Wisconsin Avenue Milwaukee, WI 53203 Milwaukee, WI 53203 Dear Mr. Holt: Re: Five Theatres Addition Marcus Theatre Corporation, Owner Oshkosh Cinema, Tenant 340 South Koller Street Oshkosh, Winnebago County Plan Number 90- 10- 0216 -C Volume: 364,962 cubic feet Inspection Fee: Paid Donald R. Holt, Suprv. Professional - Building and Heating, Building addition and heating addition plans are conditionally approved. The plans have been reviewed for compliance with the code requirements set forth in Chapters ILHR 50 -64 of the rules of the department. Construction may proceed subject to local regulations, but all items that are required to be changed by this letter must be corrected before commencing that part of the work. This plan has not been reviewed for compliance with Chapters ILHR 82 -86, the plumbing rules of the department. You are hereby advised that the owner as defined in Chapter 101.01(2)(e) of the Wisconsin State Statutes is responsible for all code requirements not specifically cited herein. The building will be inspected during and after construction. The owner shall notify the state building inspector and the local officials before taking possession of the building. ILHR 50.15 Evidence of Approval. The architect, professional engineer, designer, builder or owner shall keep, at the building, one set of plans bearing the stamp of approval. This building is classified as No. 5B, exterior masonry, unprotected w construction. 'ilrg SBD -6928 (R. 10/87) / lid /. j � S tate of r Wisconsin \ Department of Industry, Labor and Human Relations SAFETY & BUILDINGS DIVISION Donald Holt 201 E. Washington Avenue Page 2 P.O. Box 7969 Madison, Wisconsin 53707 November 12, 1990 ILHR 52.012 (3) The Stores Room 15 will be greater than 100 square feet and will require sprinklers, if the existing wall is removed. ILHR 52.012 (1 )(b) 1. Sprinklers are required in mezzanines exceeding 2,500 square feet, except that a 2,500 square foot mezzanine is permitted to be provided with smoke detectors which are wired to the manual fire alarm system which is audible at all occupied areas of the building. ILHR 51.03, Table A Line 20, and ILHR 51.02 (11) The mezzanine floor level shall be separated from the first floor level by 1 -hour fire - resistive construction. This includes 1 -hour glass at the projection ports, or fire shutters, or fire doors in various locations. Sincerely, Duane E. Peterson Plan Examiner (608) 266 -7849 DEP:1519e cc: R -3 Ochs (414) 929 -3167 Friday ��- Building Inspector, Oshkosh ./L- 4c � SBD -6928 (R. 10/87)