Loading...
HomeMy WebLinkAbout2008-Building (no permit) INSPECTION SERVICES DIVISION ROOM 205 CITY OF OSHKOSH 10 DEPARTMENT OF COMMUNITY DEVELOPMENT 215 CHURCH AVE OSHKOSH CORRECTION NOTICE PO Box 1130 ON THE WATER OSHKOSH WI 54903 -1130 Issue Date 8/28/2008 Compliance Date 9/3/2008 IMMEDIATELY Compliance No Address 102 W 5TH AVE Name Address City State Zip Code Sent to u Owner LLC RIVERFRONT DEVELOPMENT II 55 E JACKSON BLVD 500 CHICAGO IL 60604 -0000 Li Required for Occupancy Occupancy Commercial Introduction There is no record of a Razing Permit being issued for the demolition activity at this site. Item # 1 Code 7 -8 Compliance No Compliance Date 09/03/2008 IMMEDIATELY Description No building shall be built, altered or demolished until the required permits are secured. 08/28/2008 Last Updated Summary All demolition activity shall cease until the required Permits are obtained. Violations must be corrected and approved within 30 days unless otherwise noted. Call for reinspections prior to concealment and /or occupancy. Upon completing the corrections, the owner /contractor /agent must sign and date at the bottom of this notice and return it to the Inspection Services Division by the Compliance Date of 9/3/2008 Office hours for obtaining permits are Monday through Friday 7:30 -8:30 a.m. and 12:30 -1:30 p.m. or by appointment. To schedule inspections please call the Inspection Request line at 236 -5128 noting the address, permit number (when applicable), and the nature of what n =,- ds t • • e ins , ected. o Signature / 1/ Date 6 Z SS Inspect: d by: lyn Dannhoff 236-50' adannhoff @ci.oshkosh.wi.us I hereby - • - violations listed on this report have been corrected in compliance with the applicable codes. Print Name Company Signature Date Also Sent to: LJ Bldg - LJ Elec - LJ HVAC - LJ Plbg - LJ Designer - u Other SWEETWATER PERFORMANCE 501 S MAIN ST OSHKOSH WI 54902 - LJ Inspector 14312 Page 1 of 1 Oshkosh City Assessor's Office Page 1 of 1 Home Search Records General Info Exit Akanda Oshkosh Tax Map ito P Alk OUTTeird Record Configure Map Select Parcel Your Search List Select C: Yes r i 1 View Search List View Area qs ' E' _ a Rehm Search C County a Slew Search C 1 Mile 0 1/2 Mile �, ( 1/4 Mile 0 500 Feet = i _ Select setting -�__ "n then click on map. c *Note: The buildings may not appear in their exact locations. . c t o : ■ Current Vi vi afiltaisebtd Patel Click ccs KeyMMtap ti nnev . V ! W wi nde + ,,, E:2 6TH AVEa Site Design Copyright 1999-2000 Akanda Solutions,LLC. All rights reserved. http: // bids. ci. oshkosh.wi.us /Care/ProcessSearch.asp ?radio 1 =4 &Cmd =Click &Action= 4 &MTop= 737808.020... 8/28/2008 Page 1 of 2 Dannhoff, Allyn J. From: Dannhoff, Allyn J. Sent: Monday, September 29, 2008 4:32 PM To: 'Jason Lindemann'; 'kkoziczkowski @ganther.com' Subject: FW: Sweetwater Marina - 102 W 5th Ave Jason and Ken; was not able to forward with the pictures, came back to me as undeliverable. So I am forwarding without the photos. Thanks Allyn From: Dannhoff, Allyn J. Sent: Monday, September 29, 2008 4:11 PM To: Jason Lindemann (jasonlindemann @tds.net); kkoziczkowski @ganther.com Cc: Kinney, Jackson; Muehrer, Todd M. Subject: Sweetwater Marina - 102 W 5th Ave Jason; Please be advised that all work outside of the scope for what has been Permitted must cease until plans are approved and the required Permits are obtained. An inspection today, revealed areas of work have commenced on your Factory to Yacht Club Conversion project where the Required Building Permits have not been obtained. 1. Foundations being installed under south and west walls of the remainder of the building 2. Foundation /piers - restoration and or addition of piers under the existing building. 3. Installation of patio, stairs at the north end of the building, retaining wall at west end of patio. 4. Treated plywood crawlspace skirting at the north end of the building. 5. Installation of interior partition walls. 6. Remodeling of the bathrooms, including adding showers and water heater. 7. Installation of North side entry door frame (multiple leaf frame set.) A Building Permit was issued to Homestead Builders to "button up" the south and west walls opened up when the adjoining sections of the building were razed to minimize damage from the weather. Homestead was informed a complete Building Permit for the conversion of this building to the Yacht Club could not / would not be issued until renewed Stamped State Approved Plans were secured and the required Zoning Review completed. It is my understanding plans have been submitted to both Planning and Engineering for review and approval. I also understand your architect is in the process of amending and submitting Building Plans for review and approval. Unfortunately, some of the work that has been performed to date may not be done correctly. For example: - the maximum stair risers are 7" and your landscape contractor was not aware of this and installed stairs in excess of this maximum rise. - Footings and foundation walls have been installed (possibly without the benefit of your Architect/Engineer's guidance) raising concerns whether they have been designed properly (not only to support the weight of the building, but also to properly terminate and mesh in with the rest of the building design (In this venue it was also brought to my attention that piers under the building have been reconstructed, raising the same concern about design issues.) - The contractor installing the foundations also indicated you desired to get a jump on an exterior ramp. This too cannot be constructed without proper plans being approved as there are many design issues that can result in an erroneous installation. - A quick observation with the bathrooms, the showers do not meet the accessibility requirements (transfer seats or roll in showers, hand held shower. Also a water heater(s) have been installed without permits. - The retaining wall west of the patio area appears to be stacked landscape blocks. How are they secured to resist the horizontal Forces exerted on them by the backfill material or the same force by other uses /conditions at the grade level above? 9/30/2008 Page 2 of 2 Conversations with your various contractors indicate all have been hired by you, placing you in the role of General Contractor. As such you can either require each contractor to secure their own permit and inspections or as is more of the norm, you can obtain the required Building Permit. However, no further permits can be issued until all necessary approvals are obtained. Additionally, you have been contacted in the past (8/3/06, 1/31/07, 8/30/07 and most recently this past June 18th) regarding the change of use for the south and southwest buildings on this site from factory use to vehicle repair and vehicle storage. As previously discussed, plans must be prepared and submitted for the change of use to the Planning /Zoning Division to review for Zoning Compliance and this office to review for compliance with the Building Code. Please be reminded all Building Plans submitted for review for Building Code Compliance must be prepared by a Wisconsin Registered Architect or Engineer. Please contact Todd Muehrer, Zoning Administrator for Zoning Plan Review submittal requirements and James Rabe, Engineer for guidance on the Storm Water Drainage/ Management submittal requirements. Please advise me of your status in the preparation of the necessary plans, securing the necessary reviews /approvals and securing the required Permits. Thank you. Allyn Dannhoff Director of Inspection Services 920 - 236 -5045 9/30/2008 Building Permit Work Card Job Address 102 W 5TH AVE Permit Number 0133769 Create Date 10/31/2008 Owner LLC RIVERFRONT DEVELOPMENT 11 Contractor SOPER LANDSCAPPING Category 285 - Wrecking (Industrial & Commercial Plan Occupany Permit Flood Plain Height Permit Class of Const: Use /Nature Demo H Building of Work HVAC Contr Plumbing Contr Electric Contr Inspections: Date Type Inspector Date/Time requested: • Notice Type: Ready Date/Time: • Access: Requested By: Phone Number: O Reinspect Fee Q Fee Waived ❑ Reinspect Fee Paid Page 1 of 1 Safety and Buildings 4003 N KINNEY COULEE RD commerce.wi.gov LA CROSSE WI 54601 -1831 TDD #: (608) 264 -8777 i sco n s i n www.commerce.wi.gov /sb/ Department of Commerce www.wisconsin.gov Jim Doyle, Governor Mary P. Burke, Secretary May 29, 2007 CUST ID No. 273694 ATTIC• Buildings & Structures Building Inspector ROBERT J ACORD BUILDING INSPECTION CONTRACTING SPECIALISTS INC CITY OF OSHKOSH 333 N COMMERCIAL ST STE 175 POB 1130 NEENAH WI 54956 OSHKOSH WI 54902 (Please forward a copy of this letter to the fire department conducting inspections of this project.) CONDITIONAL APPROVAL PLAN APPROVAL EXPIRES: 05/29/2008 Identification Numbers Transaction ID No. 1395112 SITE: Site ID No. 725341 Oshkosh Yacht Club Please refer to both identification 6TH Street Oshkosh ' numbers, ave, in all City of Oshkosh correspondence with the agency, FOR: Facility: 680309 OSHKOSH YACHT CLUB 6th Street Oshkosh Tenant Name or Addn/Alt Description: Oshkosh Yacht Club Object Type: Building ICC Regulated Object ID No.: 1131124 Major Occupancy: Assembly; Type VB Combustible Unprotected class of construction; Alteration plan; 8,871 project sq ft; Unsprinklered; Occupancy: A -2 Dining & Drinking; Allowable area determined by: Fire Walls The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements. The following conditions shall be met during construction or installation and prior to occupancy or use: Key Item(s) • IBC 705.6 Fire walls shall extend from the foundation to at least 30 inches above the roof on both sides, unless an exception is met. By telephone this date, designer said foundation of masonry fire wall is not properly shown on A2.0 section that does not show rated masonry wall with rated support all the way to foundation below. • IBC 705.5.1 The exterior wall shall be 1 - hour rated with opening protection provided as required for 4 feet on each side of the fire wall, unless the angle of intersection is equal to or ROBERT J ACORD Page 2 5/29/2007 exceeds 180 degrees. Rating of wall adjacent and door 11 on one end and window type B on the other end of the fire wall is not clearly shown. • IBC 302.1.1.1 /Comm 62.0302 Where Table 302.1.1 requires a fire- resistance -rated separation, the incidental use area shall be separated from the remainder of the building with a fire barrier (see IBC 702.1). Laundry room over 100 SF size does not show incidental use separation, provide information to plans at job site on how you incorporated ratings in your design to provide protection for that room 103. • IBC 1003.2.13.7 The wall and any openings within 10 feet in any direction of the exterior area of assisted rescue shall be a minimum of 1 -hour fire resistive construction with all openings in this area protected with 3/4 -hour assemblies. This is not clearly shown at doors 100 & 104 and adjacent walls (& maybe windows C & G). Verify size & location of wheelchair space outside of egress route at exterior landing to exit doors 100 & 104. Also Address • IBC 714.2 Provide fire door and shutter assemblies that have the minimum fire- protective rating required by Table 714.2. Side - hinged or pivoted swinging doors shall meet the positive pressure testing requirements of UL 10C or NFPA 252. Schedule does not show proper rating of any doors and sizes for doors 109 & 110. • ICC /ANSI A117.1 Section 404.2.4.1 The maneuvering clearances required by this code section shall be provided at door to accessible stall in women 107, verify this to building inspector. • ICC /ANSI A117.1 Section 604.2 The water closet shall be positioned with a wall to the rear and one side. The centerline of the water closet shall be 16 inches minimum and 18 inches maximum from the side wall or partition. Accessible stall in Men Shower 102 shall be verified to meet this requirement. • ICC /ANSI A117.1 Section 604.8.3 Accessible water closet compartments shall have compartment door in opposite corner than water closet. Verify to inspector that accessible toilet compartments in Men 102 is met. • ICC /ANSI A117.1 Section 608.2.1 Both Men Shower 102 and Women Shower 101 need accessible shower stall. Accessible shower compartments shall be 36 inches wide by 36 inches deep, with wheelchair clearance space 12" beyond the opening on the side opposite the controls. Verify this with the building inspector. • ICC /ANSI A117.1 Section 608.3.1 In transfer -type showers, grab bars shall be provided across the control wall and on the back wall to a point 18 inches from the control wall. Verify this with the building inspector. • IECC 102.5.2 Fenestration U- factors and solar gain heat coefficients (SGHC) for windows and doors shall use default values shown in Tables 102.5.2(1) and/or 102.5.2(2), unless the plans or specifications identify the independently tested NFRC values used in the building envelope calculations. Products installed in the field shall be labeled and certified to verify these ratings. Verify rating used for this with the building inspector. • IECC 701 /Comm 63.0701 /Comm 63.1016 When demonstrating building envelope compliance using COMcheck -EZ, the data used for computational purposes must be shown ROBERT J ACORD Page 3 5/29/2007 as a detail on the plans, be part of the building specifications, or included as a product cut sheet. Verify to building inspectors that walls and fenestrations meet the values shown or provide revised COMcheck -EZ to show building still complies as built. Submit • Comm 61.30(3) This review does not include heating, ventilating or air conditioning. The owner should be reminded that HVAC plans, calculations, and appropriate fees are required to be submitted for review and approval prior to installation. The submitted HVAC plans shall match the approved building plans. Note as per Comm 2.10 installation of HVAC without approved plans could result in double fees. Reminders • IBC 1003.2.10 Provide exit, exit access doors, and egress stairways with exit signs and directional exit signs in compliance with this section. Address the need for 90 minute continued illumination in case of power loss. • Comm 61.30(3) This review does not include lighting. Comm 63.0001. Prior to installation, lighting plans and calculations shall be prepared in compliance with the code and properly signed and sealed. The plans shall be available at the job site as requested by the Department representative or local official. A copy of the approved plans, specifications and this letter shall be on -site during construction and open to inspection by authorized representatives of the Department, which may include local inspectors. If plan index sheets were submitted in lieu of additional full plan sets, a copy of this approval letter and index sheet shall be attached to plans that correspond with the copy on file with the Department. All permits required by the state or the local municipality shall be obtained prior to commencement of construction /installation/operation. If this construction project will disturb one or more acres of land, an Erosion Control Notice of Intent (NOI) shall be filed with the department 7 days prior to any earth disturbing activities. You will need to either file the NOI and an erosion control plan summary on -line at www.commerce.wi.gov /sb or submit a completed NOI form and either a plan summary or complete plan to us, with additional fees, or to the certified municipality. In granting this approval the Division of Safety & Buildings reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state statutes 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at the telephone number listed below, or at the address on this letterhead. Sincerely, Fee Required $ 770.00 Fee Received $ 770.00 Balance Due $ 0.00 Jack A Miller Building Plan Reviewer, Integrated Services .,. (608) 785 -9348, Fax: (608) 785 -9330, M - F 7:45 am - 4:30 pm jack.miller@wisconsin.gov ROBERT J ACORD Page 4 5/29/2007 cc: Peter R Ochs, State Building Inspector, (920) 948 -3500, Friday, 7:45 A.M. - 4:30 P.M. Jason Lindemann, Southshore Redevelopment Proposed Rules: The Wisconsin Division of Safety & Buildings is in the process of adopting the 2006 International Code Council suite of building codes, including the International Existing Buildings Code, with a likely effective date in the second half of 2007. You may view or download the proposed chs. Comm 61 -65 hearing draft at www.commerce.wi.gov/SB/SB- CodeDevelopment.htrnl New Rules: Effective April 1, 2007, the Division of Safety & Buildings will be implementing new erosion control and stormwater rules in ch. Comm 60 for projects begun on or after that date. You may view or download the rules at www.commerce.wi.gov/SB/SB- CodeDevelopm.ent.html Included in the rules will be expanded erosion control coverage for all commercial construction sites regardless of size. Required erosion control submittal information to us may be done with a planned on -line webtool. Building Permit Work Card Job Address 102 W 5TH AVE Permit Number 0132716 Create Date 9/5/2008 Owner LLC RIVERFRONT DEVELOPMENT II Contractor HOMESTEAD BUILDERS LLC Category 211 - Alteration Industrial Plan E6 -2496 -0908 Occupany Permit Required Flood Plain Height Permit Class of Const: Use /Nature Industrial - Former Factory/Warehouse - Erect South and west infill walls to enclose remainder of building after demo of adjoining of Work building sections.* Note: No other work is to commence without securing required permits. HVAC Contr Plumbing Contr Electric Contr Inspections: Date Type Inspector Date/Time requested: • Notice Type: Ready Datemme: • Access: Requested By: Phone Number: O Reinspect Fee 0 Fee Waived ❑ Reinspect Fee Paid Page 1 of 1